Advertisement

Hitachi Dynamic Mechanical Analyzer DMA7100

With its exceptional overall performance and user-friendly design, the DMA7100 is ideal for uses from routine and high-level research. A navigation

TA Instruments DuraPulse™ Stent/Graft Test (SGT) Instrument

The NEW DuraPulse™ Stent/Graft test (SGT) instrument extends the performance and reliability that ElectroForce SGTs have become known for over

TA Instruments ElectroForce 5500

Advanced Characterization and Stimulation in a Compact System.

TA Instruments ElectroForce 3500

Clean, maintenance-free technology for higher force dynamic testing up to 15 kN.

TA Instruments ElectroForce 3300

Unmatched dynamic performance envelope and versatility for applications that require up to 3 kN.

TA Instruments ElectroForce 3200

Characterize a variety of materials or components on the industry’s highest-performing and most versatile table-top test instrument.

TA Instruments ElectroForce 3100

Measuring less than 50.8 cm (20 inches) tall, the ElectroForce® 3100 test instrument is the smallest in the ElectroForce product family. The 3100

TA Instruments DMA 850

TA Instruments invites you to experience the ultimate in Dynamic Mechanical Analyzers, the Discovery DMA 850. Building on superior technologies of

TA Instruments DMA 3200 High Force DMA

The DMA 3200 features patented ElectroForce linear motor technology enabling a single instrument to deliver unequalled performance and data accuracy.

Dynamic Mechanical Analysis Community

Join the Dynamic Mechanical Analysis Community and receive updates on all related articles, forums, and equipment.

Ask a Question

Please enter all fields

Add a Post to Browse Categories Questions and Answers


Advertisement

Advertisement

Questions and Answers

Questions for Dynamic Mechanical Analysis

Compression compliance calibration error

I have recently encountered an error with the code 316 defined with the title "Sample is too weak" during the compliance calibration step...

S. P. Zaoutsos

I apply a test procedure in DMA Q800 and the device starts working for a couple of seconds and after that it returns the message "Slide...

Cannot start a multifrequency run

Recently, I encountered the following problem. I define a procedure for running a multi-frequency method, and click start. The instrument appears to...

Recurrent Air Bearing Issue

Hello - I have a Q800 DMA with a recurrent air bearing Issue.  TA has been here to fix it once but it quickly stopped working again.  I...

Power supply error

Does anyone know how I can fix the following error on our Q800 DMA instrument?  "power supply furnace impredance error(405)"