Featured Product

Supelco Analytical SLB GC Capillary
Supelco Analytical SLB GC Capillary

SLB columns are designed for GC and GC-MS analysts who require low bleed, inert, durable, and consistent capillary GC columns.



View All Supelco Analytical GC Columns

Shimadzu Scientific Instruments GCMS-TQ8040

Found In: GC Systems

The first triple quadrupole with Smart Productivity for high efficiency sample throughput.

Gow-Mac Series 8100

Found In: GC Systems

The Series 8100 gives you sensitive, accurate, reproducible results.

Norgren Lip-Seal fittings

Found In: GC Components

Prior techniques failed to generate leak-free connections allowing for sample loss or contamination. Norgren AFP LipSeal fitting designs create

Falcon Analytical CALIDUS micro GAS CHROMATOGRAPH

Found In: GC Systems

Falcon Analytical Introduces the CALIDUS microGC Faster, Smaller, Smarter, Easier and Greener than Traditional Gas Chromatographs

InfoMetrix Pirouette

Found In: Software (GC)

Comprehensive Chemometrics Modeling Software

Shimadzu Scientific Instruments HS-20 Series

Found In: GC Autosamplers

The HS-20 Series is the optimal solution for volatile component analysis.

ATAS GL OPTIC Cooler

Found In: GC Components , GC Accessories

A high running cost of the inlet cooling can be greatly reduced by replacing the cryogenic system with a Peltier cooler.

Agilent Technologies 7696A Sample Prep Workbench

Found In: GC Components

Provides consistent precision and eliminates errors associated with mundane sample preparation procedures

GC - Gas Chromatography Community

Join the GC - Gas Chromatography Community and receive updates on all related articles, forums, and equipment.

Ask a Question

Please enter all fields

Add a Post to Browse Categories Questions and Answers

Questions and Answers

Questions for GC - Gas Chromatography

Thermocouple out of range

In SRI it shows an error thermocouple out of range error, I changed THERMOCOUPLE,10 node valve but problem not solved. Please suggest

instrument PC configuration

how to commucation with a computer

technician in LA

AIs there any technician to help set up of Shimadzu GC 17A ver3 , in Los Angeles

[413] IOP Communication Failure at startup - Varian GC-450

Hello, we have a gas chromatograph Varian GC-450 here in the lab with the following problem at startup: IOP Communication Failure at startup (error...

EFC Type 11 problem in Varian GC CP-3900

We have GC 3900 Varian in our Oil Technology Lab. It is displaying, "Detector EFC maximum flow exceeded' and efc shutts off all three flows...