Featured Product

Supelco Analytical SLB GC Capillary
Supelco Analytical SLB GC Capillary

SLB columns are designed for GC and GC-MS analysts who require low bleed, inert, durable, and consistent capillary GC columns.



View All Supelco Analytical GC Columns

Shimadzu GCMS-TQ8040

Found In: GC Systems

The first triple quadrupole with Smart Productivity for high efficiency sample throughput.

Gow-Mac Series 8100

Found In: GC Systems

The Series 8100 gives you sensitive, accurate, reproducible results.

Norgren Lip-Seal fittings

Found In: GC Components

Prior techniques failed to generate leak-free connections allowing for sample loss or contamination. Norgren AFP LipSeal fitting designs create

Falcon Analytical CALIDUS micro GAS CHROMATOGRAPH

Found In: GC Systems

Falcon Analytical Introduces the CALIDUS microGC Faster, Smaller, Smarter, Easier and Greener than Traditional Gas Chromatographs

InfoMetrix Pirouette

Found In: Software (GC)

Comprehensive Chemometrics Modeling Software

Shimadzu HS-20 Series

Found In: GC Autosamplers

The HS-20 Series is the optimal solution for volatile component analysis.

ATAS GL OPTIC Cooler

Found In: GC Components , GC Accessories

A high running cost of the inlet cooling can be greatly reduced by replacing the cryogenic system with a Peltier cooler.

Agilent Technologies 7696A Sample Prep Workbench

Found In: GC Components

Provides consistent precision and eliminates errors associated with mundane sample preparation procedures

GC - Gas Chromatography Community

Join the GC - Gas Chromatography Community and receive updates on all related articles, forums, and equipment.

Ask a Question

Please enter all fields

Add a Post to Browse Categories Questions and Answers

Questions and Answers

Questions for GC - Gas Chromatography

Professor of Chemistry

I have a HP 5971A GC-MS. The oil diffusion pump is not as hot as it used to be. Is there any place I can get a used one before it fails? Many thanks...

CP-3800

My CP-3800 Automation stops after three injections.Can anyone suggest what could be the reason? Thanks in advance for the solution.

Issues with Front Inlet Temp & Front Detectoc Reference flow

i make use of the 6890 GC by agilent. Notice the "Not Ready" light indicator remains ON even when the set point values for Front Inlet Temp and Front...

Negative peak occur during Blank run without flame,

Last two month , I have faced the problem in my GC - 2014with negative peak occure during  Blank run. first  I have doubted in...

mislabeling of peaks

I use chemstation and when i run a sample, the chromatogram labels the peaks with the retention times instead of the compound names, and it also wont...

See all GC - Gas Chromatography Questions and Answers