Advertisement

Life Science

Lonza Group Ltd. 4D-Nucleofector™ System

Found In: Electroporation

The 4D-Nucleofector™ System was developed to offer advanced performance, flexibility and convenience. The system is controlled by intuitive

AMSbio Biotin Labeled Proteins

Found In: Sample Preparation Supplies , Western Blotting

Our exclusive biotinylated protein collection is specially designed to simplify your research.

Wyatt Technology DynaPro Plate Reader II

Found In: Microplate Readers

The DynaPro® Plate Reader II performs high-throughput, automated dynamic light scattering (DLS) measurements on macromolecular and nanoparticle

Seward Stomacher 400 EVO

Found In: Tissue Processors

The World’s leading laboratory blender for food microbiologists has EVOlved.

Promega Spectrum Compact CE

Found In: Capillary Electrophoresis

One Compact System Optimized For a Broad Range of Applications

BrandTech Scientific BRAND Liquid Handling Station

Found In: Liquid Handling

The BRAND Liquid Handling Station pipetting robot handles routine tasks at high speed and with the highest precision. The LHS closes the gap between

Analytik Jena qTOWER

Found In: PCR / Thermal Cyclers

The qTOWER, a newcomer on the real-time market, sets new standards for speed.            Based on the established rapidPCR, the qTOWER is

Thermo Fisher Scientific FEI HeliScan™ microCT

Found In: Imaging Systems

The most versatile micro computed-tomography (microCT) solution for quantitative analysis in a wide variety of Materials Science applications.

Ask a Question

Please enter all fields

Add a Post to Browse Categories Questions and Answers


Advertisement

Advertisement

Questions and Answers

Questions for Life Science

Eppendorf mastercycler gradiant lid Tsensor error

I rebuilt the power supply in htis unit, powers up fine now but gives T sensor 3 err code Any help would be greatly appreciated

spot all over

HI, We have a UVP imager and I got spots all over my picture on my western blot and around it, even when I take a picture with nothing I get...

Tip Pickup Failure

Hello,  Our JANUS system with a Varispan 8 tip arm is repeatedly failing to pick up tips from the tip holder. Deck calibration has been done...

Sensor

Dear friends.I have a TC-5000 but it has a problem with the lid heater and i need to change it but i do not know how can i do it? May you help me...

No Cycler is available

"No cycler is available" for thermocycler ProS eppendorf and the electrical current is not detected by the thermoblock (no light on the...

See all Life Science Questions and Answers

Advertisement

Advertisement

Advertisement