Buck Scientific 310 Soil Gas GC System

The 310 Soil Gas GC is similar to the Environmental GC, except that it is more compact and does not include a purge & trap. This configuration has

Buck Scientific Thermionic Ionization Detector (TID)

The Thermionic Ionization Detector is similar in design to the FID and NPD. The electrically heated thermionic bead (TID bead) is positioned so that

Buck Scientific Thermal Conductivity Detector (TCD)

Because it detects all molecules, the Thermal Conductivity Detector is commonly used for fixed gas analysis (O2, N2, CO, CO2, H2S, NO, etc.) where

Buck Scientific Photo Ionization Detector (PID)

The Buck PID uses the industry standard 10.6eV PID lamp in a spring-loaded mount, which allows the lamp to be removed, cleaned and re-installed in

Buck Scientific Nitrogen-Phosphorus Detector (NPD)

The Nitrogen-Phosphorus Detector responds to nitrogen-phosphorus compounds about 100,000 times more strongly than normal hydrocarbons. Due to this

Buck Scientific Helium Ionization Detector (HID)

The Helium Ionization Detector is a "universal" detector which responds to all molecules except neon. The HID is particularly useful for volatile

Buck Scientific Flame Photometric Detector (FPD)

The Flame Photometric Detector can detect sulfur compounds, such as H2S or SO2, down to about 200 ppb and phosphorus compounds to 10 ppb. While not

Buck Scientific Flame Ionization Detector (FID)

Our FID employs a unique ceramic ignitor which can run hot continuously, immediately re-igniting the flame even when presented with large water

Buck Scientific Dry Electrolytic Conductivity Detector (DELCD)

The Dry Electrolytic Conductivity Detector is useful for low-level detection of chlorinated and brominated solvents in environmental samples and

GC Detectors Community

Join the GC Detectors Community and receive updates on all related articles, forums, and equipment.

Ask a Question

Please enter all fields

Add a Post to Browse Categories Questions and Answers


Advertisement

Advertisement

Questions and Answers

Questions for GC Detectors

Air flow higher than 200 ml/min

I am running EZ Chrome software on a 7890B with FPD. I would like to be able to set my air flow higher than 200 ml/min. I am wondering how to disable...

Will not light Lamp

Lamp lit indicator flashes at switch on have tried a new lamp same problem. Checked all cables and connectors all seem good.

Difference in calibration standard result

I calibrated an SCD-GC with a 1 ppmW total sulfur in Helium matrix balance but noticed wide difference in the result of a known certified standard (1...

OXIDIZER THE VALUE IN PANEL 1.

I WANT YOU GUIVE ME SOLUTION FOR TO  RESOLVE THIS PROBLEME THE TRUE VALUE OF OXIDIZER  IS 65.0

7890B GC compatability with Empower

These are the firmware which will come with the Agilent GC and headspace. 7890B GC : B.02.03 G4513A Autosampler: 10.08 G4514A Autosampler...