Instrument Specialists Inc. TMA 800

Found In: Thermomechanical Analysis

TMA – THERMOMECHANICAL ANALYZER    The TMA is based on the proven vertical performance design utilizing an Oil Float Suspension System.

PerkinElmer DSC 4000

Found In: Differential Scanning Calorimetry

This single-furnace, heat flux DSC is designed to run all your routine applications day-in and day-out.

PerkinElmer DSC 6000

Found In: Differential Scanning Calorimetry

See what enhanced performance can do for you. DSC 6000 – Advanced single furnace design with MT-DSC

PerkinElmer DSC 8000

Found In: Differential Scanning Calorimetry

With our new DSC 8000 you can expect greater sensitivity and accuracy then you ever thought possible.

PerkinElmer DSC 8500

Found In: Differential Scanning Calorimetry

This new double-furnace DSC, features our second-generation HyperDSC® technology.

PerkinElmer DSC-Raman Hyphenation

Found In: Raman Spectrophotometers , Differential Scanning Calorimetry

Two complimentary techniques that when combined provide greater insight into material changes of polymers and pharmaceuticals at a molecular level

PerkinElmer TGA 4000

Found In: Thermogravimetric Analysis

Get the answers you need with less effort than you thought possible. TGA 4000 delivers great results - all day, every day

PerkinElmer TG-IR Hyphenation

Found In: Infrared Spectrophotometers , Thermogravimetric Analysis

A Thermogravimetric Analyzer (TGA) combined with an Infrared Spectrometer (TG-IR) is the most common type of Evolved Gas Analysis(EGA) system.

PerkinElmer TG-MS Hyphenation

Found In: Thermogravimetric Analysis

The combination of a TGA with a MS allows you to detect very low levels of impurities in real time.

Thermal Analyzers Community

Join the Thermal Analyzers Community and receive updates on all related articles, forums, and equipment.

Ask a Question

Please enter all fields

Add a Post to Browse Categories Questions and Answers


Advertisement

Advertisement

Questions and Answers

Questions for Thermal Analyzers

Error 405 and 420

I keep getting the error message "power supply furnace impredance error(405)" and "power supply furnace impredance error, value 127...

Auto sampler reads (illegal tip contact)

The auto sampler fails the self test by stating "illegal tip contact" when aligning the tray anyone know how to fix this?

what connects to the silver tubes sticking out of my unit?

Two silver tubes are sticking out of my unit, and i am not sure what connects to them? chiller? liquid nitro? any insight is appreciated.

Quote

Could you send me a quotation.

Quote

You you send me a quotation of DSC-Raman Setup