OI Analytical 5390 Tandem PID/XSDv

Found In: GC Detectors

The Model 5390 Tandem PID/XSD is a patented tandem detector configuration incorporating the popular 4430 Photoionization Detector (PID) and the 5360

OI Analytical 5390 Tandem PID/XSD

Found In: GC Detectors

This patented tandem detector offers the production of two gas chromatograph (GC) detectors, the 4430 PID and 5360 XSD, in one efficient package. Its

OI Analytical 5360 and 5360A XSD

Found In: GC Detectors

The XSD installs in the standard detector port of most GC makes and models.

OI Analytical 5360A XSD

Found In: GC Detectors

The Model 5360 and Model 5360A Halogen Specific Detectors (XSD™) were developed for the selective detection of halogen-containing compounds

OI Analytical 5320 ELCD

Found In: GC Detectors

The Model 5320 Electrolytic Conductivity Detector (ELCD) is a third-generation ELCD designed for selective detection of halogen-containing compounds.

OI Analytical 4450 Tandem PID/FID

Found In: GC Detectors

The Model 4450 Tandem PID/FID is a patented combination detector incorporating the Model 4430 Photoionization and Model 4410 Flame Ionization

OI Analytical 5350 Tandem PID/ELCD

Found In: GC Detectors

The Model 5350 Tandem PID/ELCD packs in the power of two great detectors: Model 4430 PID and Model 5320 ELCD, removing the need for separate analyses

OI Analytical 4430 Photoionization Detector (PID)

Found In: GC Detectors

Our Model 4430 PID’s unique patented Window Sweep™ design prevents the sample stream from contacting and contaminating the lamp window. It also

OI Analytical 5320 Electrolytic Conductivity Detector (ELCD)

Found In: GC Detectors

The Model 5320 is our third-generation ELCD. It combines three key components: a reactor assembly, cell-solvent assembly, and detector controller.

OI Analytical 5360 XSD™ (Halogen Specific Detector)

Found In: GC Detectors

The Model 5360 XSD™ offers superior selectivity for detection of halogen-containing compounds.

GC - Gas Chromatography Community

Join the GC - Gas Chromatography Community and receive updates on all related articles, forums, and equipment.

Ask a Question

Please enter all fields

Add a Post to Browse Categories Questions and Answers


Advertisement

Advertisement

Questions and Answers

Questions for GC - Gas Chromatography

CFR Compliance of TotalChrom software

We have older version of TotalChrom software connected to Clarus GC, which is not fully CFR compliant.   Is it possible to connect the...

FID flame out

I have been troubleshooting my GC for awhile now and I am leaning toward the problem being the FID flame ignition. I think I will need to replace the...

hardware problem

2010 Rom ver 1.1120 (0676) Hardware monitor mode. How can it be resolved

Samles position in the tray disappeared from method and run control window on ChemStation (Agilent 6890)

Hi everyone, I have updated the ChemStation version on a Agilent 6890 GC, couple of months ago, and on the method and run controll window I had...

troubleshooting

column sensor error is displayed in my GC Ms(qp 2010 series). How to resolve the problem? how can i do mainatainance this problem? Plz would you...

See all GC - Gas Chromatography Questions and Answers