OI Analytical Standards Addition Module

Found In: GC Components

The Standards Addition Module (SAM) is an option for the Model 4551A Autosampler that automatically adds internal standards or surrogate/matrix spike

OI Analytical Series 2010 MINICAMS® Continuous Air Monitor

Found In: GC Systems

The Series 2010 MINICAMS is a modular and extremely flexible system for near-real-time continuous air monitoring of organic species and is easily

OI Analytical S-PRO Sulfur Analysis System

Found In: GC Systems

The S-PRO System analyzes sulfur compounds in gaseous and liquified petroleum gas (LPG) streams. The completely automated GC system incorporates OI

OI Analytical pHDetect

Found In: GC Components

The pHDetect (Patent Pending) is an optional, external module for the Eclipse 4660 Purge-and-Trap (P&T) Sample Concentrator that automates

OI Analytical Flame-Ionization Detector

Found In: GC Detectors

The FID combines with the Photoionization Detector (PID) for simultaneous, dual detection of saturated and unsaturated hydrocarbons. Occupying only

OI Analytical Fluorinated By-Products Analyzer

Found In: GC Systems

Automatically quantify fluorinated contaminants in process streams using the Fluorinated By-Products Analyzer.    The FBA determines

OI Analytical Eclipse Air-Tube Desorber

Found In: GC Components

The Air-Tube Desorber Accessory provides an economical means of diversifying into air toxics analysis using the Eclipse 4660 Purge-and-Trap Sample

OI Analytical 5383 Pulsed Flame Photometric Detector

Found In: GC Detectors

The superior sensitivity of the 5383 PFPD makes it the instrument of choice for the analysis of sulfur, phosphorus, and other elements. Its linear,

GC - Gas Chromatography Community

Join the GC - Gas Chromatography Community and receive updates on all related articles, forums, and equipment.

Ask a Question

Please enter all fields

Add a Post to Browse Categories Questions and Answers


Advertisement

Advertisement

Questions and Answers

Questions for GC - Gas Chromatography

Hydrogen sulfide peak not showing on SCD GC

I use the DB-Sulfur column in 7890GC in conjuction with a Sulfur Chemiluminescence Detector (SCD) to analyze for sulfur species (H2S, COS, MeSH, EtSH...

Front Inlet Septum Purge Shutdown

After initiating the method, the GC septum purge flow refuse to attain its set point of 3ml/min. Septum Purge flow remain stagnant on 0.1ml/min...

Samles position in the tray disappeared from method and run control window on ChemStation (Agilent 6890)

Hi everyone, I have updated the ChemStation version on a Agilent 6890 GC, couple of months ago, and on the method and run controll window I had...

Touch Screen

The touch screen on the GC has completely inverted, but still able to function. Any ideas?Thanks!

ASTM Noise Drift

Hello guys I need to know how i calculate the ASTM Noise and drift in my GC 2010 plus. My software GC solution does not have baseline check icon...