Advertisement

OI Analytical Standards Addition Module

Found In: GC Components

The Standards Addition Module (SAM) is an option for the Model 4551A Autosampler that automatically adds internal standards or surrogate/matrix spike

OI Analytical Series 2010 MINICAMS® Continuous Air Monitor

Found In: GC Systems

The Series 2010 MINICAMS is a modular and extremely flexible system for near-real-time continuous air monitoring of organic species and is easily

OI Analytical S-PRO Sulfur Analysis System

Found In: GC Systems

The S-PRO System analyzes sulfur compounds in gaseous and liquified petroleum gas (LPG) streams. The completely automated GC system incorporates OI

OI Analytical pHDetect

Found In: GC Components

The pHDetect (Patent Pending) is an optional, external module for the Eclipse 4660 Purge-and-Trap (P&T) Sample Concentrator that automates

OI Analytical Flame-Ionization Detector

Found In: GC Detectors

The FID combines with the Photoionization Detector (PID) for simultaneous, dual detection of saturated and unsaturated hydrocarbons. Occupying only

OI Analytical Fluorinated By-Products Analyzer

Found In: GC Systems

Automatically quantify fluorinated contaminants in process streams using the Fluorinated By-Products Analyzer.    The FBA determines

OI Analytical Eclipse Air-Tube Desorber

Found In: GC Components

The Air-Tube Desorber Accessory provides an economical means of diversifying into air toxics analysis using the Eclipse 4660 Purge-and-Trap Sample

OI Analytical 5383 Pulsed Flame Photometric Detector

Found In: GC Detectors

The superior sensitivity of the 5383 PFPD makes it the instrument of choice for the analysis of sulfur, phosphorus, and other elements. Its linear,

GC - Gas Chromatography Community

Join the GC - Gas Chromatography Community and receive updates on all related articles, forums, and equipment.

Ask a Question

Please enter all fields

Add a Post to Browse Categories Questions and Answers


Advertisement

Advertisement

Questions and Answers

Questions for GC - Gas Chromatography

Zone Heater Driver Error

I'm getting a Thermal Shutdown Zone Heater Driver fault on a 6890N after replacing the mainboard. the mainboard came directly out of a working...

memory reset error

HiWhen we try to wake up a GC from its long time sleep, we faced some problems. Previously, we used this gc. We know the parts installed vs.. After 1...

memory reset error

  Hi When we try to wake up a GC from its long time sleep, we faced some problems. Previously, we used this gc. We know the parts...

apc out of control error

apc out of control error 2112 coming up

troubleshooting

column sensor error is displayed in my GC Ms(qp 2010 series). How to resolve the problem? how can i do mainatainance this problem? Plz would you...