The Q600 provides a true simultaneous measurement of weight change (TGA) and true differential heat flow (DSC) on the same sample from ambient to 1,500 °C. It features a field-proven horizontal dual beam design with automatic beam growth compensation, and the ability to analyze two TGA samples simultaneously. DSC heat flow data is dynamically normalized using the instantaneous sample weight at any given temperature.
Q600
Attributes
Additional Specifications System Design: Horizontal Balance & Furnace
Balance Design: Dual Beam (growth compensated)
Sample Capacity: 200 mg (350 mg including sample holder)
Balance Sensitivity: 0.1 Μg
Furnace Type: Bifilar Wound
Temperature Range: Ambient to 1500 °C
Heating Rate – Ambient to 1000 °C: 0.1 to 100 °C/min
Heating Rate – Ambient to 1500 °C: 0.1 to 25 °C/min
Furnace Cooling:
Forced Air (1500 to 50 °C in < 30 min,
1000 °C in 50 °C in < 20 min)
Thermocouples: Platinum/Platinum-Rhodium (Type R)
Temperature Calibration: Curie Point or Metal Standards (1 to 5 Points)
DTA Sensitivity: 0.001 °C
Calorimetric Accuracy/Precision: ± 2% (based on metal standards)
Mass Flow Controller with Automatic Gas Switching: Included
Vacuum: to 7 Pa (0.05 torr)
Reactive Gas Capability: Included – separate gas tube
Dual Sample TGA: Included
Auto-Stepwise TGA: Included

Sample Pans
Platinum: 40 ΜL, 110 Μl
Alumina: 40 ΜL, 90 ΜL

Features

Thermobalance
  • Accurate and reliable horizontal dual-balance
  • Supports both DSC and TGA measurements
  • Weight signal is the differential between the sample and reference beams
  • Less drift compared to single-beam designs
  • Independent TGA measurements on two samples simultaneously

Temp Control & Measurements
  • Platinum/Platinum-Rhodium thermocouple pair
  • Direct sample reference and differential temperature from ambient to 1500°C
  • Superior ΔT accuracy compared to single-beam designs
  • True differential heat flow signal
  • Superior baseline performance

Furnace
  • Rugged, bifilar-wound, horizontal furnace
  • Accurate and precise heating rate ramps and isothermal operation
  • Smooth automatic furnace opening/closing
  • Easy sample loading
  • Rapid post-experiment furnace cool-down

Purge Gas System
  • Field-proven, horizontal purge gas system
  • Dual digital mass flow controllers and gas switching capability
  • Inconel® reactive gas inlet
  • Easily interfaced to a MS or FTIR
  • Better baselines with minimum buoyancy effects

Photos

  • Q600 Front
  • Q600 Rear
Q600 Front

Q600 Front

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Picture of TA Instruments Q600
TA Instruments reputation for high technology products, quality manufacturing and unbeatable after sales support is why more customers recommend TA products...

More about TA Instruments

Visit TA Instruments

Questions and Answers

Recent Question Activity

Ask a Question

Power supply furnace impedance error

Has anyone seen this message?

TA Q600 SDT PROBLEM

sir our ta q600 sdt has a problem.when we sample run instroment show the massage temperature limit exceeded and run terminated.sir how we remove this problem. 

Negative Heat Flow DSC

why the heat flow values are negative for all my curves (different heat rate and particle size)obtained by this instrument, can anyone help me how to correct or subtract the baseline, thanks at advance

See all 11 TA Instruments Q600 Questions and Answers There are 11 Threads

Reviews

Member Reviews

There are no threads in TA Instruments Q600 Reviews at this time.
Add a Review

Buy it Used!

Used TA Instruments Q600 Offerings on LabX

Gently used Q600 TGA

Price: Please Email

Condition:

Configuration: As Shown

TA Instruments Q600 TGA/DTA

Price: NEGOTIABLE

Condition:

Configuration: As Shown

Advertisement