DSC131 evo: for testing, QC and academic thermal analysis laboratories. An instrument designed from the ground up to be robust, high performance and above all user friendly featuring market leading intuitive CALISTO software and low operating costs.
DSC131 evo
Attributes
Cooling Rate .01 to 100 °C/min
Temperature Range 28 to 700 °C
DSC Type Heat Flux DSC
Heating Rate .01 to 100 °C/min
Depth 22.8 in
Height 15.7 in
Width 20.9 in
Power Requirements 230 V - 50/60 Hz.
Weight 82.5 lbs
Additional Specifications Temperature range:     
Ambient to 700 °C    
With cooling accessories:     
-170 °C to 500 °C (Liquid Nitrogen Accessory)    
-70 °C to 400 °C (Cryothermostat)    
Programmable temperature scanning rate(heating and cooling):     
0.01 to 100 °C.min-1    
Cooling time:     
12 min (500 °C to 100 °C) Air    
5 min (100 °C to 0 °C) Cryothermostat    
6 min (200 °C to 25 °C) Liquid Nitrogen Accessory    
12 min (25 °C to -100 °C) Liquid Nitrogen Accessory    
RMS Noise (200°C):     
1.5 µW    
Resolution:     
0.8 µW    
Time constant:     
3 s    
Gases:     
included gas switch from gas A to gas B    
Crucibles:     
30 µl, 100 µl    
aluminum, alumina, incoloy, etc.    
Pressure (non controlled):     
High pressure crucible (up to 500 bars / 7255 psi at 600 °C)

Features

Robustness: the DSC131 evo features a highly robust sensor that, if needed, can readily be changed by the user in less than 30 minutes. No other DSC offers such flexibility.    
    
Ease of operation: dedicated market leading CALISTO software that is not only intuitive but powerful enough to perform every typical experiment and data treatment.    
    
Flexible and powerful: from -170 to 700 °C, with rapid heating and cooling performance.    
    
Large range of crucibles: in addition to the regular 30 µl crucibles, crucibles with a capacity of 100 µl are used for analyzing heterogeneous samples and for optimizing Cp (heat capacity) measurements.    
    
High Pressure Crucibles: The High Pressure crucibles deliver unmatched High Pressure resistance (up to 500 bars / 7 250 psi, 600 °C) while the DSC sensor itself remains at atmospheric pressure.

Photos

DSC131 evo

DSC131 evo

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Picture of Setaram Instrumentation DSC131 evo
For fifty years, Setaram Instrumentation (Caluire, France) has been the global supplier of solutions in thermal analysis and calorimetry, a domain of...

More about Setaram Instrumentation

Visit Setaram Instrumentation

Questions and Answers

Recent Question Activity

Ask a Question

Dr

I have a DSC 131 evo but when i carry out a experiment have a message " the apparatus DSC 131 evo- No option is not connected"; and when i click in the  apparatus connection appear the new menssage " connection error: '2...

maintenance

Is it possible to find a maintenance manual for this product somewhere?

There are 2 Threads

Reviews

Member Reviews

There are no threads in Setaram Instrumentation DSC131 evo Reviews at this time.
Add a Review

Buy it Used!

Used Setaram Instrumentation DSC131 evo Offerings on LabX

Used Labsys EVO Removed from Local Lab in Working Condition

Price: $45,000.00

Condition:

Configuration: As Shown

Advertisement