The ultra-high heating and cooling rates add a new dimension to the study of thermally induced physical transitions and chemical processes, for example, the crystallization and reorganization of polymers. The revolutionary Flash DSC 1 enables you to investigate effects that were previously impossible to measure.
Flash DSC 1
Attributes
DSC Type Power Compensated DSC
Cooling Rate -6 to -240000 K/min
Heating Rate 30 to 2400000 K/min
Additional Specifications Temperature range:     
Air cooling (Room temperature + 5 K) … 500 °C    
IntraCooler (1-stage):     
-35 °C … 450 °C    
IntraCooler (2-stage):     
-95 °C … 420 °C    
Cooling rates (typical):     
-6 K/min. (-0.1 K/s) … -240 000 K/min (-4 000 K/s)    
Heating rates (typical):     
30 K/min. (0.5 K/s) … 2 400 000 K/min (40 000 K/s)    
Sensor material:     
Ceramic    
Thermocouples:     
16    
Sample size:     
10 ng … 1 Μg    
Sampling rate:     
Max. 10 kHz (10 000 points per second)

Features

Ultra-high cooling rates – allow materials with defined structural properties to be prepared    
    
Ultra-high heating rates – reduce measurement times and suppress reorganization processes    
    
Fast response sensor – enables the kinetics of extremely fast reactions or crystallization processes to be studied    
    
High sensitivity – low heating rates can also be used; scan rates overlap with those of conventional DSC    
    
Wide temperature range – measurements can be performed in the range -95 to 450 °C    
    
User-friendly ergonomics and functionality – sample preparation is quick and easy

Photos

Flash DSC 1 - Flash Differential Scanning Calorimeter

Flash DSC 1 - Flash Differential Scanning Calorimeter

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Picture of METTLER TOLEDO Flash DSC 1
METTLER TOLEDO instruments are used in research, scientific and quality control labs, amongst many others in the pharmaceutical, chemical, food and cosmetics...

More about METTLER TOLEDO

Visit METTLER TOLEDO

Questions and Answers

Recent Question Activity

Ask a Question

Composition chip

Hi! I would be interested in knowing the chemical composition of the standard chip used in the Flash DSC 1. In particular the part in direct contact with the sample. Thanks in advance for the reply.

Measurements on polymer thin films

We are involved in calorimetric investigation on polymer thin films. We are encountering some problems in placing correctly the film in the chip. The solutions we are trying are the following: 1) We prepare externally the film and transfer...

There are 2 Threads

Reviews

Member Reviews

There are no threads in METTLER TOLEDO Flash DSC 1 Reviews at this time.
Add a Review

Buy it Used!

Used METTLER TOLEDO Flash DSC 1 Offerings on LabX

Mettler Toledo Cryogenics Tank

Price: $47.04

Condition:

Configuration: As Shown

METTLER TOLEDO 8603 SEVENEASY PH DIGITAL METER

Price: $199.00

Condition:

Configuration: As Shown

METTLER TOLEDO 8603 SEVENEASY PH DIGITAL METER

Price: $199.00

Condition:

Configuration: As Shown

Mettler DSC 823e

Price: €€10,900.00

Advertisement

Videos

See it in action

Flash DSC 1

Flash Differential Scanning Calorimetry