PerkinElmer AxION 2 TOF MS

Share:

AxION 2 TOF MS

PerkinElmer's AxION 2 TOF MS is at the core of our new LCMS platform, which includes a suite of hardware, software and services that offer superior uptime, exceptional ease of use, and uncompromising performance.     
     
The AxION 2 TOF MS instrument is available with a choice of patented ion sources including dual probe Ultraspray™ 2 ESI or Field-Free Atmospheric Pressure Chemical Ionization (APCI). With its exact mass capabilities, AxION 2 TOF MS is the ideal tool for identification of unexpected compounds in your samples, providing a high level of resolution and mass accuracy -- consistently, day after day. The wide dynamic range allows accurate isotopic ratio and quantitation capabilities over a wide range of concentrations.
AxION 2 TOF MS
Attributes
Power Requirements 220-240 V (50-60 Hz) For a
Additional Specifications Performance     
Mass Range: 18-12,000 m/z     
Mass Measurement Accuracy: =2 ppm at 1,000 m/z with internal mass calibration     
Max Acquisition Rate: =20,000 spectra/sec. Acquired spectra are summed to generate a mass spectrum saved to disk at =70 spectra/sec     
Resolution: =12,000 FWHM at 922 m/z     
Linear Dynamic Range: 105     
     
Sensitivity     
ESI(+): S/N=40:1 1 pg/Μl reserpine @ 400 Μl/min MeOH/H2O     
ESI(–): S/N=50:1 2 pg/Μl p-nitrophenol @ 400 Μl/min MeOH/H2O     
     
Ion Sources     
Ultraspray ESI: 0.004-1.4 ml/min     
Ultraspray2 ESI: 0.004-1.4 ml/min     
Field-Free APCI: 0.05-1.5 ml/min     
     
Operation/Other     
Vacuum Stages: 5 stages     
Turbo Pump: 10/30/200/400 L/sec     
Roughing Pump: Edwards® E2M28     
Operating Temperature: 16 ºC-26 ºC     
Footprint: 40.6 x 76.8 x 152.4 cm (16 x 30 x 60 in) with ion source extending 7.6 cm (3 in) from front panel

Features

         
  • Exact mass capability and wide dynamic range facilitate compound identification and quantitation     
  • Adjustable dual-probe ion source can be fine-tuned to optimize sensitivity and delivers simultaneous spray for advanced internal calibration     
  • Proprietary Trap and Pulse technology increases sensitivity 3-5x     
  • V-shaped flight path maximizes ion transmission for superior sensitivity     
  • High acquisition speed allows for fast chromatography     
  • Choice of software packages tailored to specific applications and workflows     

Photos

AxION ™ 2 TOF MS.

AxION ™ 2 TOF MS.

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Picture of PerkinElmer AxION  2 TOF MS
Improving human and environmental health is their focus. From earlier insights and more effective therapies to cleaner water and safer buildings where...

More about PerkinElmer

Visit PerkinElmer

Questions and Answers

Recent Question Activity

Ask a Question

NO SPRAY MIST FROM ESI NEEDLE WHEN CARRYING OUT AN AUTOTUNE

I am trying to execute an autotune using the syringe pump. However, there is no mist spray from the needle. I have checked for blockage in the line, and I can confirm there is none. Can anyone offer advice on what I could do. I allowed the equipment...

Troubleshooting: Source door says

Hello, I am a graduate student who is having a random issue with the AxION 2 TOF MS source door. I have never had this problem before and no one in my lab knows what to do. The source door is closed, however, under status in TOF MS Driver, in...

There are 2 Threads

Reviews

Member Reviews

There are no threads in PerkinElmer AxION 2 TOF MS Reviews at this time.
Add a Review

Buy it Used!

Used PerkinElmer AxION 2 TOF MS Offerings on LabX