The Super Aquarius instruments offer all the features of the Cecil Aquarius double beam instrument with additional optical sophistication,enhanced performance and added power.

Super Aquarius is the choice for versatility, ultimate performance and the measurement of diverse and difficult samples.

Models

CE 9200
Attributes

This model was added by: WrenchAdmin2

Edit Model

Bandwidth 1.8 nm
Optics Double Beam
Photodetector Photomultiplier
Photometric Noise 0.00003A (500nm, 2s response, 0A) RMS
Scanning Speed 1-4000 nm/second
Stray Light Less than 0.01% at 220nm and 340nm. As Pharmacopeia using KCl: Absorbance greater than 2A at 200nm
Wavelength Range 190 to 800 nm
Wavelength Resolution 1.8 nm selectable 0.5, 1, 2 and 4 nm
Depth 410 mm
Height 196 mm
Width 805 mm
Power Requirements 110-250V, 50/60Hz, 180W
Weight 37 kg
Additional Specifications Wavelength Accuracy: 900nm R option and CE 9500 : 0.5nm
Wavelength Accuracy: 0.1nm at deuterium 656.1nm peak
Wavelength Reproducibility: 0.1nm
Photometric Reproducibility: Better than 0.0001A, 500nm
Baseline Flatness: 0.001A
Stability: Better than 0.0001A/hour, 500nm
Display Screen LCD: Displays menus, spectra, curves, data etc.
Screen Display Scrolling: 550mm viewing width for spectra, plots etc.
Overlayed Spectra: Up to 8 spectra with or without offsets
Dynamic Scan Recall: The 8 most recent scans are held for recall
Photometric Readout: -0.3-3A; 0-200%T; 0-9999C
Photometric Accuracy: 0.004A at 1A
Derivative Spectra: 1st - 4th derivatives (1st - 6th CE 9500)
Kinetics, Single and Multi-Cell: Calculation of rate, with plot for up to 6 cells
Method and Data Storage: For 100 methods with data
Spectral Reprocessing: Spectral scans may be expanded, transformed or derivatised and replotted over any wavelength range
Quantitative Curve Fitting: Linear, quadratic or cubic to 30 standards
Cell and Wavelength programming: 8 cells and 10 wavelengths in any combination
Assay Program: Program computation of user entered formulae
Storage With Password Security: 100 spectra, time plots and reaction curves
Alpha Numeric Text Entry: For annotation and formula entry
Sample Temperature Control: Single or multi-cell, water or thermoelectric
Micro Sipette Sampling: Under MPU control, with or without sample return
Real Time Clock: Timed and dated reports for GLP
Computer and Printer Interfaces: Bi-directional serial RS232c and parallel ports
CE 9500
Attributes

This model was added by: WrenchAdmin2

Edit Model

Bandwidth 0.5, 1, 2 and 4 nm CE 9500 selectable 0.5, 1, 2 and 4 nm
Optics Double Beam
Photodetector Photomultiplier
Photometric Noise 0.00003A (500nm, 2s response, 0A) RMS
Scanning Speed 1-4000 nm/second
Stray Light Less than 0.01% at 220nm and 340nm. As Pharmacopeia using KCl: Absorbance greater than 2A at 200nm
Wavelength Range 190 to 900 nm
Wavelength Resolution 1.8 nm
Depth 410 mm
Height 196 mm
Width 805 mm
Power Requirements 110-250V, 50/60Hz, 180W
Weight 37.5 kg
Additional Specifications Baseline: Full baseline for each bandwidth in safe memory
Derivative Spectra: 1st to 6th derivatives
Turbid Sampling Optical System: Fitted standard, turbid sample holder provided
Precision Low Noise Measurement: Absorbance measurements with 0.1mA precision
Spectrofluorescence Measurements: Fluorescence accessory; Excitation wavelength scanning
Gel Scanning: Accessory available for 100mm gels
Wavelength Accuracy: 900nm R option and CE 9500 : 0.5nm
Wavelength Accuracy: 0.1nm at deuterium 656.1nm peak
Wavelength Reproducibility: 0.1nm
Photometric Reproducibility: Better than 0.0001A, 500nm
Baseline Flatness: 0.001A
Stability: Better than 0.0001A/hour, 500nm
Display Screen LCD: Displays menus, spectra, curves, data etc.
Screen Display Scrolling: 550mm viewing width for spectra, plots etc.
Overlayed Spectra: Up to 8 spectra with or without offsets
Dynamic Scan Recall: The 8 most recent scans are held for recall
Photometric Readout: -0.3-3A; 0-200%T; 0-9999C
Photometric Accuracy: 0.004A at 1A
Derivative Spectra: 1st - 4th derivatives (1st - 6th CE 9500)
Kinetics, Single and Multi-Cell: Calculation of rate, with plot for up to 6 cells
Method and Data Storage: For 100 methods with data
Spectral Reprocessing: Spectral scans may be expanded, transformed or derivatised and replotted over any wavelength range
Quantitative Curve Fitting: Linear, quadratic or cubic to 30 standards
Cell and Wavelength programming: 8 cells and 10 wavelengths in any combination
Assay Program: Program computation of user entered formulae
Storage With Password Security: 100 spectra, time plots and reaction curves
Alpha Numeric Text Entry: For annotation and formula entry
Sample Temperature Control: Single or multi-cell, water or thermoelectric
Micro Sipette Sampling: Under MPU control, with or without sample return
Real Time Clock: Timed and dated reports for GLP
Computer and Printer Interfaces: Bi-directional serial RS232c and parallel ports
CE 9260 & CE 9560
Attributes

This model was added by: WrenchAdmin2

Edit Model

Optics Double Beam
Photodetector Photomultiplier
Photometric Noise 0.00003A (500nm, 2s response, 0A) RMS
Scanning Speed 1-4000 nm/second
Stray Light Less than 0.01% at 220nm and 340nm. As Pharmacopeia using KCl:[/b] Absorbance greater than 2A at 200nm
Wavelength Range 190 to 800 nm
Wavelength Resolution 1.8 nm selectable 0.5, 1, 2 and 4 nm
Depth 410 mm
Height 196 mm
Width 805 mm
Power Requirements 110-250V, 50/60Hz, 180W
Weight 37.5 kg
Additional Specifications Comes with Cecil TD Software and six or eight cell changer.
Baseline: Full baseline for each bandwidth in safe memory
Derivative Spectra: 1st to 6th derivatives
Turbid Sampling Optical System: Fitted standard, turbid sample holder provided
Precision Low Noise Measurement: Absorbance measurements with 0.1mA precision
Spectrofluorescence Measurements: Fluorescence accessory; Excitation wavelength scanning
Gel Scanning: Accessory available for 100mm gels
Wavelength Accuracy: 900nm R option and CE 9500 : 0.5nm
Wavelength Accuracy: 0.1nm at deuterium 656.1nm peak
Wavelength Reproducibility: 0.1nm
Photometric Reproducibility: Better than 0.0001A, 500nm
Baseline Flatness: 0.001A
Stability: Better than 0.0001A/hour, 500nm
Display Screen LCD: Displays menus, spectra, curves, data etc.
Screen Display Scrolling: 550mm viewing width for spectra, plots etc.
Overlayed Spectra: Up to 8 spectra with or without offsets
Dynamic Scan Recall: The 8 most recent scans are held for recall
Photometric Readout: -0.3-3A; 0-200%T; 0-9999C
Photometric Accuracy: 0.004A at 1A
Derivative Spectra: 1st - 4th derivatives (1st - 6th CE 9500)
Kinetics, Single and Multi-Cell: Calculation of rate, with plot for up to 6 cells
Method and Data Storage: For 100 methods with data
Spectral Reprocessing: Spectral scans may be expanded, transformed or derivatised and replotted over any wavelength range
Quantitative Curve Fitting: Linear, quadratic or cubic to 30 standards
Cell and Wavelength programming: 8 cells and 10 wavelengths in any combination
Assay Program: Program computation of user entered formulae
Storage With Password Security: 100 spectra, time plots and reaction curves
Alpha Numeric Text Entry: For annotation and formula entry
Sample Temperature Control: Single or multi-cell, water or thermoelectric
Micro Sipette Sampling: Under MPU control, with or without sample return
Real Time Clock: Timed and dated reports for GLP
Computer and Printer Interfaces: Bi-directional serial RS232c and parallel ports

Features

  • Variable Optical Bandwidth
  • Powerful Integral Control
  • Top Performance Optical System
  • Turbid Sampling Optics
  • Display Scrolling for Wide View
  • Integral Data Storage

Variable Optical Bandwidth

The top of the range CE 9500, offers four optical resolutions, 0.5, 1, 2 and 4nm. For samples with narrow absorption bands such as vapours and gases, the narrow 0.5nm bandwidth is extremely valuable. When high energy is helpful, for instance in measuring difficult turbid samples or fluorescence measurements, the 4nm bandwidth provides increased sensitivity and accuracy of measurement.

Powerful Integral Control

The rapid operating system of the Super Aquarius instruments includes a mass of powerful software including complete instrument programming, band area correction and computation, spectral differencing and stripping etc. The software may be expanded by E-SEF - Encoded Software Enhancement Facility. Codes are available by telephone, fax or E-mail with no delay. A large built in memory stores 100 scans, plots, curves and methods all password protected.

Top Performance Optical System

A high performance end on photomultiplier is used in a fully symmetrical optical system to provide the best possible measuring accuracy, with low noise, even when making difficult low energy measurements. Baseline stability is at least 10 times better than for single beam instruments.

Turbid Sampling Optics

Strongly scattering samples display very high absorbance when measured normally. These may be measured accurately with the turbid sample optical system in Super Aquarius instruments.

Display Scrolling for Wide View

Long scans, time plots and data tables may all be viewed by scrolling the screen display. Six screen widths - 550mm - of display may be viewed, not just one screen of information as is normal with other instruments.

Integral Data Storage

Up to 100 each of wavelength scans, time plots, Kinetic plots or calibration curves may all be stored in memory, for future use, protected by the operators personal security codes.

Dissolution

Special version of each of the instruments suitable for tablet dissolution applications using Cecil TD software and a six or eight cell changer.

Photos

PHOTO_1

PHOTO_1

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Picture of Cecil Instruments Super Aquarius Series
Cecil Instruments are leading designers and manufacturers of HPLC systems, Ion Chromatography systems and UV / Visible Spectrophotometers. Cecil Instruments’...

More about Cecil Instruments

Visit Cecil Instruments

Questions and Answers

Recent Question Activity

Be the first to Ask a Question

Reviews

Member Reviews

There are no threads in Cecil Instruments Super Aquarius Series Reviews at this time.
Add a Review