Agilent Technologies 6890N

Share:

6890N

The Agilent 6890N is a state-of-theart gas chromatograph that provides superior performance for all applications. Key to its performance is the use of advanced electronic pneumatic control (EPC) modules and high performance temperature control. Each EPC unit is optimized for its intended use with a specific inlet and detector option. Temperature control of the 6890N oven allows for fast and precise temperature ramping. Overall thermal performance provides optimal chromatography including peak symmetry, retention time repeatability, and retention index accuracy. The combination of precise pneumatic control and accurate temperature control leads to outstanding retention time repeatability, the basis for all chromatographic measurement. A full array of traditional gas sampling and column switching valves are available. A new highperformance inert pneumatic switching manifold is available for a number of advanced chromatographic applications (2-D heart cutting, detector splitting, etc). Agilent GC systems are known for their reliability, ruggedness, and long life. The Agilent 10-year use guarantee provides greater assurance for a low-cost of ownership throughout its life.      
      
Discontinued      
      
The Agilent 6890N GC has been obsoleted. This includes the G1530N, G1530N-EU, G1540N, and G1942N mainframes and all associated options. Agilent will provide guaranteed support for these products through July 31, 2015. Accessories for your 6890N GC can still be ordered.      
      
The 7890A GC system is the latest gas chromatograph from Agilent and is the replacement product for the 6890N.
6890N
Attributes
Programmable Yes
Detector Flame ionization detector, Thermal conductivity detector (All detectors include EPC)
GC System Type Modular
Humidity 5% to 95% Ambient operating
Number of Detectors 2
Depth 21.6 in
Height 19.7 in
Width 22.8 in with EPC inlet and detectors
Weight 108 lbs

Features

System Capabilities      
          
  • Dual channel design supports two inlets and two detectors.      
  • Full range digital data output enables the smallest and largest peaks to be quantitated in a single run.       
  • Full EPC is available for all inlets and detectors. Control range and resolution are optimized for the specific inlet or detector module.       
  • EPC with capillary columns provides four column flow control modes: constant pressure, ramped pressure (3 ramps), constant flow, or ramped flow (3 ramps). Column average linear velocity is calculated.       
  • Atmospheric pressure and temperature compensation is standard, so results do not change, even when the laboratory environment does.       
  • Automatic Liquid Sampling is fully integrated into mainframe control.       
  • Set point and automation control can be done from the local keyboard or via a networked data system. Clock-time programming can be initiated from the front panel to initiate events (on/off, method start, etc) at a future date and time.       
  • A run time deviation log is created for each analysis to ensure that all method parameters were achieved and maintained.       
  • Display of all GC and automatic liquid sampler (ALS) set points at the GC or data system. Agilent supports open connectivity by providing communication protocols to other vendors.      

Photos

PHOTO_1

PHOTO_1

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Link to more information

Picture of Agilent Technologies 6890N
Agilent is a global leader in life science, diagnostics and analytical laboratory technologies. Leveraging more than 50 years of expertise, we create...

More about Agilent Technologies

Visit Agilent Technologies

Questions and Answers

Recent Question Activity

Ask a Question

Reg: GC 6890N Error Message

On injecting the sample and pressing Start key, the Error message is: Start key disabled

PEAKS NOT LABELLED

After running the gasoline sample with the DHA Analyzer 6890n.The peaks are not labelled and the print out show empty.Please helpsoftware version AC DHA version 06.04

ERROR ON GC 6890N INVALID SERIAL NUMBER

plese help me resolve the invalid serial number displayed on my gc 6890n thanks

See all 11 Agilent Technologies 6890N Questions and Answers There are 11 Threads

Reviews

Member Reviews

There are no threads in Agilent Technologies 6890N Reviews at this time.
Add a Review

Buy it Used!

Used Agilent Technologies 6890N Offerings on LabX

Agilent- Certified Pre-Owned 6890N GC with 5973 Mass Spec

Price: Please Email

Condition:

Configuration: As Shown

Agilent 5973 inert MSD with 6890N GC & G1888 Headspace

Price: Call GenTech

Condition:

Configuration: As Shown

Agilent GC 6890N Fully Refurbished 180 Day Warranty

Price: 17,999

Condition:

Configuration: Complete System

Agilent 6890N Network GC System

Price: 9,999

Condition:

Configuration: As Shown

Agilent 5973i MSD with 6890N GC - 2 Year Warranty

Price: Call GenTech

Condition:

Configuration: As Shown

Agilent/HP 6890N GC with FID & 7683 AS - 2 Year Warranty

Price: Call GenTech

Condition:

Configuration: Complete System

Find more results for "Agilent Technologies 6890N" on LabX