Advertisement

Varian SpectrAA 220FS

Share:

SpectrAA 220FS

A fully automated double beam system with Fast Sequential operation for improved productivity. Enhanced capabilities, including full PC control and automated operation as standard. The SpectrAA 220 optics feature four lamp positions with automated wavelength and slit selection, and high intensity deuterium background correction as standard. Lamps are mounted in fixed positions, and a rotating mirror is used to select the operating lamp, eliminating the need for a conventional turret. For maximum stability in an automated sequence, a software controlled next-lamp warm up facility is provided. 
 
Conventional AA systems still determine one element at a time, repeating all samples for each element in turn. SpectrAA-220 FS provides complete results for each sample in minutes. Includes computer #31940 with Varian AA software version v3.10 installed. 
See attached brochure for more details.
SpectrAA 220FS
Attributes
Depth 79 in
Height 28 in
Width 33 in
Weight 450 lbs (estimated shipping weight)

Features

Photos

SpectrAA 220FS

SpectrAA 220FS

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Picture of Varian SpectrAA 220FS
Changes have occurred to the Varian, Inc. product lines. On May 14, 2010, Agilent Technologies completed the acquisition of Varian, Inc. (Varian), a supplier...

More about Varian

Questions and Answers

Recent Question Activity

Ask a Question

Air compressor pressure

Hi - I've just had to replace the air compressor regulators as they weren't reading correctly. Could anyone advise what the correct air pressure (in bar or psi) I should set the compressor to?  Thanks!

Maintenance cleaning guidance

Hello, I changed my acetylene gas cylinder as pressure was below 100psi. My flame will still not ignite and I assume that there might be something clogged in the spray chamber and/or nebuliser. I have not performed cleaning to an AAS...

Instrumenal Zero

I Can't put zero instrumental, somebody can tell me if I need something to resolve the? Thanks  

See all 14 Varian SpectrAA 220FS Questions and Answers There are 14 Threads

Reviews

Member Reviews

Add a Review

SpectrAA software

Overall Satisfaction Rating: 3 out of 5
Reliability Rating: 3 out of 5
Ease Of Use Rating: 3 out of 5

Could someone provide any details of software for SpectrAA 220. 

Software

Overall Satisfaction Rating: 3 out of 5
Reliability Rating: 3 out of 5
Ease Of Use Rating: 3 out of 5

Could someone provide any details to get a new version of a software for SpectrAA 220. Thanks 

There are 2 Threads

Buy it Used!

Used Varian SpectrAA 220FS Offerings on LabX