Thermo Fisher Scientific Dionex IonPac AS11-HC-4µm

Share:

Dionex IonPac AS11-HC-4µm

Achieve the optimal combination of chromatographic speed and resolution using the new Thermo Scientific Dionex IonPac AS11-HC-4µm anion-exchange column. This high-capacity, high-efficiency capillary column provides excellent resolution of a large number of organic acids and inorganic anions in complex sample matrices. Compared to the previous Dionex IonPac™ AS11-HC column, the new ion-exchange column uses smaller resin particles for more efficient separations resulting in more accurate peak integration and more reliable results. It has similar selectivity and increased peak efficiencies compared to the Dionex IonPac AS11-HC and was specifically designed to resolve a large number of inorganic anions and organic acids in a single run using a hydroxide gradient. Applications run on the Dionex IonPac AS11-HC column can be easily transferred to the Dionex IonPac AS11-HC-4µm column with the benefit of increased peak resolution, which provides more consistent results. The Dionex IonPac AS11-HC-4µm column is available in capillary format, 0.4 × 250 mm. The capillary format provides reduced eluent consumption, which helps reduce operating costs.
Dionex IonPac AS11-HC-4µm
Attributes
Pore Size 1500 Å
Depth 250 mm
Width .4 mm
Additional Specifications Maximum Operating Pressure 5000 psi (34 MPa)       
Mobile-Phase Compatibility pH 0–14; 0–100% HPLC solvents       
Bead Diameter: 4.0 µm supermacroporous resin          
Functional Group: Alkanol quaternary ammonium ion       
Latex Cross-Linking: 6%       
Latex Diameter: 70 nm       
Capacity: 2.9 µeq (0.4 × 250 mm capillary column), 0.07 µeq (0.4 × 50 mm capillary guard column)

Features

           
  • Increase chromatographic resolution and quality of results.       
  • Use for organic acids and inorganic anions in complex sample matrices or uncharacterized samples.       
  • Recommended for monovalent and divalent organic acids.       
  • Use the Dionex IonPac AS11 column for fast analysis of organic acids and anions in well-characterized samples.       
  • Use the Dionex IonPac ICE-AS1 or ICE-AS6 columns for organic acids in high-ionic-strength samples.       
  • High-pressure capillary Thermo Scientific Dionex ICS-5000 HPIC or ICS-4000 HPIC system is required to run at standard capillary flow rates.       

Photos

Thermo Scientific Dionex IonPac AS11-HC-4µm

Thermo Scientific Dionex IonPac AS11-HC-4µm

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Picture of Thermo Fisher Scientific Dionex IonPac AS11-HC-4µm
Thermo Fisher Scientific Inc. (NYSE: TMO) is the world leader in serving science, enabling our customers to make the world healthier, cleaner and safer....

More about Thermo Fisher Scientific

Visit Thermo Fisher Scientific