Leica CM1950 cryostat design is the result of extensive customer consultations. 
 
The Leica CM1950 is a highly adaptable platform that can be tailor-made for each laboratory. By starting with the standard instrument and choosing from a range of options, every laboratory can have THE clinical cryostat for their individual needs. 
 
Innovation and human-oriented features provide a cryostat with a new level of performance.
CM1950
Attributes
Max. Specimen Size 50 x 80mm
Microtome Type Rotary (Encapsulated)
Sectioning Speed .3 to .9 mm/s
Thickness Setting 1 to 100 µm
Depth 850 mm
Height 1215 mm
Width 835 mm (with handwheel)
Weight 145 kg (w/o specimen head cool.)
Part Number 14047743909 (120V/60Hz -UVV), 14047742465 (120V/60Hz - OUVV), 14047742467 (120V/60Hz - OUVVM)
Additional Specifications Operating temperature range: 18 °C to 35 °C 
Total specimen feed: 25mm + 1mm 
Vertical stroke: 59mm ±0.5mm 
Specimen retraction: 20Μm (can be deactivated)

Features

UVC disinfection 
UVC disinfection minimizes risk of contamination by infectious material. 
 
AgProtect 
AgProtect, an antimicrobial, nanosilver coating on all outside surfaces also minimizes contamination risk. 
 
Optional section waste 
Optional section waste removal system provides a safer environment using a concealed primary filter system for solid waste and a bacterial (HEPA) filter for air. 
 
Optional vacuum 
Optional vacuum assisted sectioning makes sectioning easier. 
 
Disposable blade holder 
New disposable blade holder with dovetail mounting plate and knife holder base provides larger clamping surface and working distance and supports reproducible section quality

Photos

Leica CM1950

Leica CM1950

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Picture of Leica Biosystems CM1950
Leica Biosystems creates worldwide centers of excellence to ensure we build the highest quality manufacturing facilities and the most innovative development...

More about Leica Biosystems

Visit Leica Biosystems

Questions and Answers

Recent Question Activity

Ask a Question

Chamber Temp Warm

I've been involved in troubleshooting a CM1950 where the chamber temperature will warm up to about +9C (set for -18C). The compressor and the evaporator fan will be running at that time as well. If I power the unit down for just 3 minutes and...

ERROR F1.13 on LEICA cryostat CM1950

hI I HAVE AN ERROR F1.13 ON A LEICA CRYOSTAT CM1950 AND THERE IS NO DISPLAY FOR OBJECT TEMPERATURE.THANKS YOU , PAUL VAN BELLINGEN vbellingen@yahoo.fr

PM light wont turn off

Does anyone know how to clear wrench icon which basically is alerting PM is due?