Advertisement

EXSTAR TG/DTA7000 Series

Share:

TG/DTA7000 Series

Newly developed simultaneous thermogravimetry and differential thermal analysis (TG/DTA, TGA/DTA) with high performances. µg level weight changes can be detected and precisely measured with high sensitivity horizontal balance systems. The base line performance is improved by adopting newest digital technology.

Models

7200,7220
Attributes

Edit Model

Additional Specifications Temperature Range:  
Ambient to 1100°C 
(When using TG/DTA7220 Sample Observation Option from ambient to 500ºC) 
Balance Type:  
Horizontal Differential Type 
TG Measurement Range:  
±400mg 
TG Sensitivity:  
0.2µg 
DTA Measurement Range:  
±1000µV 
Scan Rate:  
0.01 to 150°C/min 
Purge Gas Flow Rate:  
0 to 1000ml/min 
Cooling Time:  
1000 to 50°C Within 12min
TG/DTA7300
Attributes

Edit Model

Additional Specifications Temperature Range:  
Ambient to 1500°C
Balance Type:  
Horizontal Differential Type 
TG Measurement Range:  
±400mg 
TG Sensitivity:  
0.2µg 
DTA Measurement Range:  
±1000µV 
Scan Rate:  
0.01 to 100°C/min 
Purge Gas Flow Rate:  
0 to 1000ml/min 
Cooling Time:  
1000 to 50°C Within 12min
Auto Sampler Unit
Attributes

Edit Model

Additional Specifications Number of Samples:
Max. 50nos

Features

New Balance Control Technology   
The newly-developed “Horizontal Digital Dual Beam System” guarantees the highest baseline stability and the lowest noise levels ever seen in TG/DTA (TGA/DTA) analysis.   
   
New Temperature Control Functions   
Temperature precise, accuracy and cooling performances are improved with newly designed FRONT STREAM temperature control technology and low heat capacity furnace technology.   
High Cooling Rate   
   
High Throughput Measurement with Full Line-Up Options
   
Newly developed Auto-sampler system and MASS flow control technology can satisfy variety application requirements.   
   
"Real View TG/DTA" Sample Observation Option
   
TG/DTA7220 can easily switch to a real view measurement. Real View TG/DTA displays and saves the changes of samples during a measurement by linked images. After the measurement, you smoothly display and analyze by loading the saved image using analysis software and linking to temperature and each signal. More highly reliable information is obtained for evaluating thermal analysis behavior.

Photos

EXSTAR TG/DTA7000 Series

EXSTAR TG/DTA7000 Series

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Questions and Answers

Recent Question Activity

Be the first to Ask a Question

Reviews

Member Reviews

There are no threads in EXSTAR TG/DTA7000 Series Reviews at this time.
Add a Review

Advertisement