Advertisement

Chemyx Fusion Touch

Share:

Fusion Touch

Precision laboratory fluid delivery with wide flow ranges and high delivery accuracy.           
           
Set any parameter through a familiar "windows" like environment and change settings from syringe ID, flow rate, volume, and delay time. Syringe dimensions can also be loaded from an internal syringe library stored on the pump. Dual entry modes allow users to wear gloves and still operate the system.     
high-precision fluid dosing

Models

Fusion 100
Attributes

Edit Model

Depth 165 mm
Height 114 mm
Width 241 mm
Weight 3 kg
Additional Specifications Mode Infuse Only 
Accuracy ± < 0.35% 
Reproducibility ± < 0.05% 
Syringe Size (Min/Max) 0.5µL to 60mL 
Syringe Flow Rates See Syringe Library for Min & Max Flow Rates 
Minimum Flow Rate 0.001 ΜL/min (with 0.5ΜL syringe) 
Maximum Flow Rate 102 mL/min (with 60mL syringe) 
Linear Force 35lb (15.9kg) 
Display4.3 inch LCD Touch Screen 
ConnectivityUSB-B, RS232 and TTL Ports 
System Dimensions 9.5 x 6.8 x 4.4 inches (24 x 17 x 11 cm) 
Power 110/220 VAC 
Motor Drive0.9? Stepper Motor with Micro-stepping 
Step Resolution 0.098 µm/step 
Operating Temperature 4°C to 40°C (40°F to 104°F) 
Storage Temperature-10°C to 70°C (14°F to 158°F) 
Humidity 20% to 80% RH, non-condensing 
Classification Class 1 
Installation Category II 
Regulatory ComplianceCE, RoHS, REACH, FCC, IC
Fusion 200
Attributes

Edit Model

Depth 6.5 in
Height 4.5 in
Width 9.5 in
Weight 3 kg
Additional Specifications Mode Infuse/Withdraw 
Accuracy ± < 0.35% 
Reproducibility ± < 0.05% 
Syringe Size (Min/Max) 0.5µL to 60mL 
Syringe Flow Rates See Syringe Library for Min & Max Flow Rates 
Minimum Flow Rate 0.001 ΜL/min (with 0.5ΜL syringe) 
Maximum Flow Rate 102 mL/min (with 60mL syringe) 
Linear Force 50lb (23kg) 
Display 4.3 inch LCD Touch Screen 
Connectivity USB-B, RS232 and TTL Ports 
System Dimensions9.5 x 6.8 x 4.7 inches (24 x 17 x 12 cm) 
Power 110/220 VAC 
Motor Drive0.9? Stepper Motor with Micro-stepping 
Step Resolution 0.046 µm/step 
Operating Temperature 4°C to 40°C (40°F to 104°F) 
Storage Temperature -10°C to 70°C (14°F to 158°F) 
Humidity 20% to 80% RH, non-condensing 
Classification Class 1 
Installation Category II 
Regulatory ComplianceCE, RoHS, REACH, FCC, IC
Fusion 400
Attributes

Edit Model

Depth 6.5 in
Height 4.5 in
Width 9.5 in
Weight 3 kg
Additional Specifications Infusion-only with high volumetric accuracy for microfluidics and microdialysis use.   
Flow Rate:  
Minimum (0.5 Μl syringe): 2 pl/min  
Maximum (10 ml syringe): 10 ml/min  
Linear Force:   
50 lbs with variable force selection  
Step Resolution:   
0.016 microns

Features

  • high-precision fluid dosing           
  • wide flow ranges           
  • syringe manufacturer independent           
  • constant and variable flow           
  • USB, RS232, TTL for PC control
  • Photos

    Manuals and Resources

    Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

    Picture of Chemyx Fusion Touch
    Chemyx is a precision syringe pump manufacturer and a scientific instrumentation OEM integration partner for companies in the life sciences, chemicals,...

    More about Chemyx

    Visit Chemyx

    Questions and Answers

    Recent Question Activity

    Be the first to Ask a Question

    Reviews

    Member Reviews

    There are no threads in Chemyx Fusion Touch Reviews at this time.