Advertisement

Tosoh Bioscience TSKgel H Series

Share:

TSKgel H Series

TSKgel H series columns are recommended for the analysis of organic-soluble polymers and are packed with spherical particles composed of polystyrene cross-linked with divinylbenzene (PS-DVB). The TSKgel HT columns are for high temperature applications (<140ºC), while the TSKgel HT2 columns are used in ultra-high temperature (up to 220ºC) applications.     
     
Please note: the "GM" prefix denotes a column packed with particles of different pore sizes blended to provide an extended linear calibration curve.

Models

High Temp GPC Columns (HT)
Attributes

Edit Model

Additional Specifications TSKgel column
1) GMHhr-H(S) HT
2) G2000Hhr-HT
3) GMHhr-H(20) HT
4) GMHhr-H(30) HT
5) GMHhr-H HT
6) GMHxl-HT

Particle size
1) 13 µm
2) 20 µm
3) 20 µm
4) 30 µm
5) 5 µm
6) 13 µm

Pore size
1) mixed pore sizes
2) 2nm
3) mixed pore sizes
4) mixed pore sizes
5) 2nm
6) mixed pore sizes

Exclusion limit
1) 4.0 × 108 Da
2) 4.0 × 104 Da
3) 4.0 × 108 Da
4) 4.0 × 108 Da
5) 4.0 × 108 Da
6) 4.0 × 108 Da
High-Temp Gel Permeation - HT2
Attributes

Edit Model

Additional Specifications TSKgel column 
1) GMHhr-H(20) 
2) GMHhr-H(30) HT2 
3) GMHhr-H(S) HT2 
4) G2000Hhr-HT2  
 
Particle size 
1) 20 µm 
2) 30 µm 
3) 13 µm 
4) 20 µm 
 
Pore size 
1) mixed pore sizes 
2) mixed pore sizes 
3) mixed pore sizes 
4) 2nm 
 
Exclusion limit 
1) 4.0 × 108 Da 
2) 4.0 × 108 Da 
3) 4.0 × 108 Da 
4) 1.0 × 1048 Da 

Features

TSKgel High Temperature columns are for the analysis of organic-soluble polymers. These columns are for applications up to 140°C and are shipped in o-dichlorobenzene (ODCB), which can be exchanged for 1-chloronaphthalene and trichlorobenzene.     
     
TSKgel Ultra-High Temperature columns are for the analysis of organic-soluble polymers at extremely elevated temperatures. These columns are for applications up to 220°C and are shipped in o-dichlorobenzene (ODCB), which can be exchanged for 1-chloronaphthalene and trichlorobenzene.      
     
The TSKgel mixed bed columns are packed with particles of different pore sizes that are blended to provide an extended linear calibration curve. Mixed bed columns are used when a broad range of polymer molar masses is expected in the sample.     
     
The issue of shearing that occurs with the analysis of ultra-high molar mass polymers is overcome by the TSKgel GMHhr-H(S) HT column. The (S) is a reference to this shearing effect.

Photos

TSKgel

TSKgel

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Picture of Tosoh Bioscience TSKgel H Series
 
Tosoh Bioscience continues to be a leader in the field of bioseparations ever since it was established in 1987 as TosoHaas. In 2000 we became a wholly-owned...

More about Tosoh Bioscience

Visit Tosoh Bioscience

Questions and Answers

Recent Question Activity

Be the first to Ask a Question

Reviews

Member Reviews

There are no threads in Tosoh Bioscience TSKgel H Series Reviews at this time.
Add a Review

Tosoh Bioscience TSKgel H Series Articles

Helpful Resources, Articles, and Information

Tosoh Bioscience LLC is proud to announce the introduction of our newest gel permeation chromatography/size exclusion chromatography (GPC/SEC)...

See All Related Articles