Advertisement

Gilson Automated GX-271 GPC Clean-up System

Share:

Automated GX-271 GPC Clean-up System

The Automated GX-271 GPC Clean-up System provides an affordable solution for laboratories performing residue analysis of complex matrices such as fatty foods, soils, sludge, animal and plant tissue.     
     
Automate post-extraction clean-up of interfering substances from environmental samples, food products, and animal tissue by Gel Permeation Chromatography (GPC) prior to analysis by GC, GC/MS, HPLC, or LC/MS. Failure to remove these interfering compounds can cause poor analytical results, shorten column life, and increase analytical downtime.
Automated GX-271 GPC Clean-up System
Attributes
Additional Specifications Pump:      
Reciprocating pump with single-piston interchangeable head, constant stroke and fast refill motion, internal pulse dampener and pressure feedback     
Accuracy:      
< ± 1%     
Repeatability:     
< 1%     
Flow Rate:     
10 uL/min to 10 mL/min     
Dimensions (w x d x h):      
33 x 33 x 15 cm (13 x 13 x 6 in)     
Maximum Pressure:      
4000 psi (276 bar)     
Injection Volume:      
GX-271 Liquid Handler/Injector: 20 uL to 5 mL (5 mL standard)     
Vertical Punch Strength:      
3.2 kg (7 lb) for septum piercing     
Syringe Pump:      
402 Single Syringe Pump with 10 mL syringe     
Sample Rack Capacity Options:      
13 x 100 mm tubes, 16 x 100 mm tubes and other options available upon request     
Collection Rack Capacity Options:      
25 x 200 mm tubes, 38 x 200 mm tubes, 125 mL or 250 mL Boston Round Bottles, Caliper TurboVap™ Evaporation Tubes (50 and 200 mL, Labconco RapidVap Evaporation Vessels (100 mL flat, 450 mL flat or with stem), 125 mL and 250 mL flasks for rotary evaporation and other options available upon request.     
UV Detector:      
Wavelengths at 254nm or 280 nm with 40 uL Flow Cell (10 mm path length)     
Software Control:      
Computer control via Ethernet communication and TRILUTION® LC Software     
GPC Clean-up Columns:     
Compatible with various GPC Clean-up columns from low pressure glass to high pressure stainless steel     
Optional GPC System Organizer Dimensions (w x d x h):     
39.2 x 37.9 x 93.7 cm (15.5 x 14.9 x 36.9 in)     
Environmental Conditions:      
For indoor use only     
Altitude: 2000 m     
Temperature: 5ºC - 40ºC     
Air pressure: 75 - 105 kPa     
Pollution degree: 1 or 2, in accordance with IEC 66     
Humidity: Maximum relative humidity 80% for temperatures up to 31º C, decreasing linearly to 50% relative humidity at 40ºC     
Manufacturing Standards:      
Meets applicable safety and EMC certification standards; UL and CE certified     
Fuse:     
5 x 20 mm “T” type 2.50A     
One for 100 - 120V; two for 220 - 240V     
Power Requirement:      
Frequency: 50 - 60 Hz     
Voltage: 100 - 240V (universal input)     
Current rating: 2.0A for 100 - 120V or 1.0A for 220 - 240V     
Dimensions (w x d x h):      
59.7 x 54.1 x 57.1 cm (23.5 x 21.3 x 22.5 in)

Features

  • The system features a Direct Injection Module and a fraction collection valve located on the Z-arm, increasing efficiency by reducing sample carryover and post valve dead volume.     
  • The Automated GPC system is controlled with TRILUTION® LC Software, a user-friendly, easy-to-use, flexible program that was specifically designed to meet the laboratory needs. The software features pre-programmed methods specific to GPC post-extraction clean-up processes.     
  • Gilson GPC Clean-up Systems meet clean-up guidelines set forth by the USEPA, USFDA, USDA, USGS, ISO, CFIA, AOAC International and European Union (EN 1528, EN 12393, S19) requirements.
  • Photos

    Automated GX-271 GPC Clean-up System

    Automated GX-271 GPC Clean-up System

    Manuals and Resources

    Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

    Picture of Gilson Automated GX-271 GPC Clean-up System
    From the original PIPETMAN®, Gilson enables scientists to reproducibly simplify and advance sample preparation for biomolecule, environmental and...