At the start of a run there's a S7 system error that appears.
Read Post
- Forum: Beckman Coulter Avanti® J Series Questions and Answers
- Last Post: January 29th, 2013
| Attributes | |
|---|---|
|
This model was added by: WrenchHelp last edited by: LabWrenchEditor |
|
| Centrifuge Type | Ultraspeed |
| Maximum Capacity | 4 liters (Single tube Volume Range 1.5 - 1,000 mL) |
| Maximum RCF | 110500 xg |
| Maximum Speed | 30000 rpm |
| Noise Level | < 57 dB |
| Orientation | Floor Standing |
| Refrigerated | Yes CFC-Free non-ozone depleting refrigerant |
| Speed Range | E-1 to 30000 rpm 0 to 6,000 rpm for elutriation |
| Depth | 34.5 in |
| Height | 34.1 in |
| Width | 28 in |
| Weight | 680 lbs |
| Additional Specifications | Approximate Acceleration Time: Maximum, slow, or timed (1 to 10 min from 0 to 500 rpm) Approximate Deceleration Time: Maximum, slow, timed (1 to 10 min from 500 to 0 rpm), or off Friction Reduction System (FRS): A mechanical rotary vane pump reduces chamber pressure dependent on rotor and run speed Maximum Heat Dissipation into Room under Steady-State Conditions: 2.0 kW (6,900 Btu/hr) Set Speed: Actual rotor speed ± 10 rpm from 10,000 to 30,000 rpm or equivalent RCF Set Time: 1 min to 99 hr 59 min or continuous (hold) Temperature Control: ± 2°C of set temperature (after equilibration) Ambient Temperature Range: 16 to 38°C Clearances Required: 7.6 cm (3.0 in) sides; 16.0 cm (6.25 in) rear Door: 5.4-cm (2.1-in) thick structural foam with steel plate Humidity Restrictions: < 95% (noncondensing) Pollution Degree: 2 Rotor Chamber Diameter: 40.6 cm (16 in) Time -- Actual Display: Indicates run time remaining (timed run) or elapsed time (hold run) |
| Attributes | |
|---|---|
|
This model was added by: WrenchHelp last edited by: LabWrenchEditor |
|
| Centrifuge Type | Ultraspeed |
| Maximum Capacity | 6 liters (single tube volume range: 1.5 - 1,000 mL) |
| Maximum RCF | 82000 xg |
| Maximum Speed | 26000 rpm |
| Noise Level | < 57 dB |
| Orientation | Floor Standing |
| Refrigerated | Yes CFC-Free non-ozone depleting refrigerant |
| Speed Range | 100 to 26000 rpm or equivalent RCF |
| Depth | 34.5 in |
| Height | 34.1 in |
| Width | 28 in |
| Weight | 640 lbs |
| Additional Specifications | Approximate Acceleration Time: Maximum, slow, or timed (1 to 10 min from 0 to 500 rpm) Approximate Deceleration Time: Maximum, slow, timed (1 to 10 min from 500 to 0 rpm), or off Drive Cooling: Air Cooled Drive Type: SR* Drive Friction Reduction System (FRS): A mechanical rotary vane pump reduces chamber pressure to 0.25 ATM (190 mm [7.5 in] Hg) Maximum Heat Dissipation into Room under Steady-State Conditions: 2.0 kW (6,900 Btu/hr) Rotor ID: Auto Set Speed: Actual rotor speed ± 10 rpm from 10,000 to 26,000 rpm or equivalent RCF Set Time: 1 min to 99 hr 59 min, 2t, or continuous (hold) Speed Control: ± rpm of set speed or 0.1%, whichever is greater Speed Range: 0 to 5,000 rpm for elutriation Temperature Control: ± 2°C of set temperature (after equilibration) Zonal Capability: Yes Ambient Temperature Range: 15 to 40°C |
| Attributes | |
|---|---|
|
This model was added by: WrenchHelp last edited by: LabWrenchEditor |
|
| Centrifuge Type | Ultraspeed |
| Maximum Capacity | 6 liters (single tube volume range: 1.5 - 1,000 mL) |
| Maximum RCF | 82000 xg |
| Maximum Speed | 26000 rpm |
| Noise Level | < 57 dB |
| Orientation | Floor Standing |
| Refrigerated | Yes CFC-Free non-ozone depleting refrigerant |
| Depth | 34.5 in |
| Height | 34.1 in |
| Width | 28 in |
| Weight | 340 lbs |
| Additional Specifications | Accel/Decel Rates 12/13 Temp Control + 2° of set temperature Speed Control + 10 rpm of set speed or 0.1%, whichever is greater Ambient Temp Range 16° to 38°C Drive Type Cooling SRDrive / Air Cooled Power Usage / Heat Output 2.0 kW / 6900 Btu/hr |
| Attributes | |
|---|---|
|
This model was added by: WrenchHelp last edited by: LabWrenchEditor |
|
| Centrifuge Type | Ultraspeed |
| Maximum Capacity | 4 liters (single tube volume range: 1.5 - 1,000 mL) |
| Maximum RCF | 53000 xg |
| Maximum Speed | 21000 rpm |
| Noise Level | < 64 dB |
| Orientation | Floor Standing |
| Refrigerated | Yes CFC-Free non-ozone depleting refrigerant |
| Speed Range | 300 to 21000 rpm |
| Depth | 31.5 in |
| Height | 36 in |
| Width | 25 in |
| Power Requirements | 50 Hz, 180 to 253 VAC, 24 A; 60 Hz, 187to229/216to264 VAC, 24 A |
| Weight | 589 lbs |
| Additional Specifications | Approximate Acceleration Time: Two profiles--MAX (full acceleration to set speed) and SLOW Approximate Deceleration Time: Three profiles--MAX, SLOW, and OFF (coast) Friction Reduction System (FRS): 190 mm (7.5 in) Hg Maximum Heat Dissipation into Room under Steady-State Conditions: 2.0 kW (6,900 Btu/hr) Set Speed: Actual rotor speed ± 50 rpm of set speed Set Time: to 99 hr 59 min or continuous (hold) Temperature Control: ± 2° C of set temperature (after equilibration) Ambient Temperature Range: 15° C to 35° C Clearances Required: 7.6 cm (3.0 in) sides; 16.0 cm (6.25 in) rear Humidity Restrictions: < 95% (noncondensing) Pollution Degree: 2 Time -- Actual Display: Indicates run time remaining/displays elapsed time Finish Control panel: silicone elastomer. Top surface: urethane paint. Other surfaces: general purpose paint. |
Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

At the start of a run there's a S7 system error that appears.
Read Post
REQUIRED FSR LEVEL NOT REACHED
Read Post
REQUIRED FSR LEVEL NOT REACHED
Read Post
BECKMAN COULTER service and repair facilities worldwide as soon as possible. Assurance and professional. ... Read More
There are no threads in Beckman Coulter Avanti® J Series Preventative Maintenance at this time - be the first to Add Preventative Maintenance Post
Press releases and Articles
University of Uppsala Professor Honored for Lifetime of Innovation Professor Wilhelm Einar Stellan Hjertén of the Institute of...
Speed and Precision Increased in Biological, Chemical and Industrial Applications DelsaMax particle analyzers measure the size and...
Labeled and Unlabeled Monoclonals Offer Specificity, Convenience, Flexibility Beckman Coulter Life Sciences is expanding their flow...
There are no threads in Beckman Coulter Avanti® J Series Reviews at this time - be the first to Add a Review