Advertisement

Beckman Coulter Avanti J-E

Share:

Avanti J-E

Compact High Performance Centrifuge that fits directly in your lab  
  
Whether your application is related to Cellomics, Genomics, or Proteomics, Avanti J-E with speeds up to 21,000 rpm (53,300 x g) coupled with powerful *SR drive technology provides you with fast separations.  
  
A comprehensive line of labware, with up to twenty-four 96-well microtiter plate processing, 4 x 1L bottles, and disposable HarvestLine System Liners extend the versatility of this centrifuge. For clinical research applications, conical tubes and bottles for swinging bucket rotors spin volumes of 15, 50, 250, and 500 mL for effective blood component isolation with a variety of gradient kits.  
  
The J-E is energy efficient for low heat output plus the quiet operation ensures a comfortable, productive work environment.
Avanti J-E
Attributes
Centrifuge Type High Speed
Maximum Capacity 4 L
Maximum RCF 53300 xg
Maximum Speed 21000 rpm
Noise Level < 64 dB
Orientation Floor Standing
Refrigerated Yes CFC-Free non-ozone depleting refrigerant
Speed Range 300 to 21000 rpm
Depth 31.5 in
Height 36 in
Width 25 in
Power Requirements 50 Hz, 180 to 253 VAC, 24 A; 60 Hz, 187to229/216to264 VAC, 24 A
Weight 589 lbs
Additional Specifications Ambient Temp Range: 15° to 35°C  
Drive Type / Cooling: SRDrive / Air Cooled  
Power Usage / Heat Output: 2.0 kW / 6900 Btu/hr  
Accel/Decel: 2/3  
Approximate Acceleration Time: Two profiles--MAX (full acceleration to set speed)and SLOW   
Approximate Deceleration Time: Three profiles--MAX, SLOW, and OFF (coast)   
Friction Reduction System (FRS): 190 mm (7.5 in) Hg   
Maximum Heat Dissipation into Room under Steady-State Conditions: 2.0 kW (6,900 Btu/hr)   
Set Time: to 99 hr 59 min or continuous (hold)   
Temperature Control: ± 2° C of set temperature (after equilibration)   
Clearances Required: 7.6 cm (3.0 in) sides; 16.0 cm (6.25 in) rear   
Humidity Restrictions: < 95% (noncondensing)   
Pollution Degree: 2   
Time -- Actual Display: Indicates run time remaining/displays elapsed time   
Finish: Control panel: silicone elastomer. Top surface: urethane paint. Other surfaces: general purpose paint.  
Speed Control: 25 rpm of set speed or 0.1%, whichever is greater

Features

Quick on the job  
      
  • Shorter run times mean more discovery for you. Avanti J-E's high torque switched reluctance (SR) drive gives you more time at speed and less time getting there.  
Shares lab space with others  
      
  • The Avanti J-E is about the size of a portable dishwasher. The small footprint gives you the freedom to place it right in your lab, so it's where you need it, when you need it.   
Conservative and Resourceful  
      
  • Avanti J-E uses a maintenance free vacuum to reduce friction on the rotor, allowing for a smaller motor and compressor that generates less heat, and less energy usage. These energy efficient components not only prolong the life of the centrifuge, but also increase savings when amortized over time.  
Widely respected in rotors  
      
  • For Volume requirements ranging from microplates to 1-liter bottles, Avanti J-E's extensive rotor library maximizes capacity and optimizes g-force. The library includes: general purpose, high capacity (4 liter), and biosafe certified rotors with patented dual locking lids for safe sample transportation  

Photos

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Picture of Beckman Coulter Avanti J-E
Beckman Coulter, Inc. is a leading manufacturer of biomedical testing instrument systems, tests and supplies that simplify and automate laboratory processes....

More about Beckman Coulter

Visit Beckman Coulter

Questions and Answers

Recent Question Activity

Ask a Question

D-6 / D-15 drive errors

Hi - After swapping out rotors a few times, we seem to be stuck on a D-6 and D-15 drive error.  It has happened in the past and was cleared out with an "enter-4-1-1-CE" code and it resumed use.  This time it will not clear out...

mismatch rotor display with the right rotor

Hi, we used the right rotor for J-E with right set in the system. However, the screen later displayed mismatch rotor. Can we continue to use it? Or what to do?

Beckman J6-m1 JE-5.0 Elutriation System

All,  I have an old Beckman J6-m1 Centrifuge that runs a JE-5.0 elutriation System. My Strobe lamp has quit working. I am told by Beckman that the Lamp has been dis-continued; they do not have a replacemrnt. Doe anyone have any ideas where...

See all 14 Beckman Coulter Avanti J-E Questions and Answers There are 14 Threads

Reviews

Member Reviews

There are no threads in Beckman Coulter Avanti J-E Reviews at this time.
Add a Review

Buy it Used!

Used Beckman Coulter Avanti J-E Offerings on LabX

Beckman Coulter JLA-9.1000 Rotor and Cups

Price: 9,900.00

Condition:

Configuration: Complete System

Beckman Coulter JLA-16.250 Rotor

Price: $1,650.00

Condition:

Configuration: As Shown

Beckman Coulter Avanti J-HC Centrifuge with JS-5.0 Rotor

Price: $19,900.00

Condition:

Configuration: As Shown

Beckman - Avanti J-25I

Price: $10,500.00

Condition:

Configuration: As Shown

Beckman Coulter - Centrifuge Rotor JA-14 14,000RPM

Price: $1,200.00

Condition:

Configuration: As Shown

Beckman - JA-14 14,000 RPM

Price: $1,850.00

Condition:

Configuration: As Shown

Find more results for "Beckman Coulter Avanti J-E" on LabX