Rotina 420 / 420R

The Rotina 420 centrifuge is a new, compact benchtop centrifuge conceived for high sample throughput as well as for high sample volumes. With a maximum capacity of 4 x 600 ml, 140 blood collection tubes or 16 microtitre plates are ideal for applications in clinical chemistry, in biotechnology and in life science research facilities.

Developed for large volumes, yet not overly large in size. High performance when it counts, yet cost-effective and fair to your budget. The ROTINA 420 centrifuges offer these benefits and more.

The new, compact benchtop centrifuges are conceived for high sample throughput as well as for high sample volumes. With a maximum capacity of 4 x 600 ml, 140 blood collection tubes or 16 microtitre plates are ideal for applications in clinical chemistry, in biotechnology and in life science research facilities.

Models

420
Attributes

This model was added by: WrenchAdmin2

Edit Model

Centrifuge Type General Purpose
Maximum Capacity 4 x 600 ml
Maximum RCF 24400 xg for reaction tubes
Maximum Speed 15000 rpm
Orientation Benchtop
Refrigerated No_
Depth 650 mm
Height 423 mm
Width 506 mm
Power Requirements 200 – 240 V 1, 50 – 60 Hz, 750 W consumption
Weight 74 kg
Additional Specifications Running time: 1 s – 999 min, infinite continuous run, short cycle mode
Maximum RCF: Up to 16,504 for 94 ml tubes, up to 12,007 for 250 ml bottles.
420R
Attributes

This model was added by: WrenchAdmin2

Edit Model

Centrifuge Type General Purpose
Maximum Capacity 4 x 600 ml
Maximum RCF 24400 xg for reaction tubes
Maximum Speed 15000 rpm
Orientation Benchtop
Refrigerated Yes_
Depth 654 mm
Height 423 mm
Width 713 mm
Power Requirements 200 – 240 V 1, 50 Hz, 1500 VA consumption
Weight 106.5 kg
Additional Specifications Running time: 1 s – 999 min, infinite continuous run, short cycle mode
Maximum RCF: Up to 16,504 for 94 ml tubes, up to 12,007 for 250 ml bottles.

Features

Performance
  • High capacity
  • High RCF

Design
  • Metal housing
  • Stainless steel centrifuging chamber
  • Viewing port in the lid

User-friendliness
  • Automatic lid locking
  • Ergonomic control and information panel
  • Easy rotor changing
  • 99 program storage spaces

Cooling (Rotina 420R)
  • Infinitely variable adjustment from - 20 °C to + 40 °C (or - 4 °F to + 104 °F)
  • Stand-by cooling

Safety
  • Lid locking and holding
  • Emergency lid lock release
  • Lid dropping protection
  • Automatic rotor recognition
  • Imbalance switch-off
  • Motor overheating protection
  • Chamber overheating protection (ROTINA 420 R)

Options (Rotina 320R)
  • with connection for nitrogen rinsing for centrifugation of reactive substances or
    substances which are unstable in aerial oxygen. As required, a monitoring control system should be available to measure oxygen concentration.
  • as heating/cooling version up to + 90 °C (or + 194 °F) for applications calling for
    temperatures over + 40 °C.

Photos

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Picture of Hettich Rotina 420 / 420R
Andreas Hettich GmbH & Co.KG (Hettich), located in Tuttlingen, Germany, is recognized as one of the top clinical & research centrifuge manufacturers in...

More about Hettich

Visit Hettich

Questions and Answers

Recent Question Activity

Be the first to Ask a Question

Reviews

Member Reviews

There are no threads in Hettich Rotina 420 / 420R Reviews at this time.
Add a Review