Advertisement

EPPENDORF 5424/5424R

Share:

5424/5424R

This highly advanced 24-place model is unbelievable quiet and equipped with a number of innovative features. The Centrifuge 5424 and Centrifuge 5424 R set new standards for silence, speed and simplicity – for others to follow! The micro centrifuge standard in your lab – refrigerated. It features all the benefits already combined in the Centrifuge 5424 and adds the patented cooling feature for temperature sensitive samples.

Models

5424R
Attributes

This model was added by: LabWrenchSiteAdmin

Edit Model

Centrifuge Type Microcentrifuge
Maximum Capacity 24 x 1.5/2.0 mL tubes
Maximum RCF 21130
Maximum Speed 15000 rpm
Noise Level < 54 dB
Orientation Benchtop
Refrigerated Yes_
Speed Range 100 to 15000 rpm
Depth 48 cm
Height 26 cm
Width 29 cm
Peak Power 350 W
Weight 46.3 lbs
Additional Specifications No. of rotors:          
4           
Acceleration time to max. speed:           
15s           
Braking time from max. speed:           
16s           
Temperature settings:           
-10°C to +40°C
5424
Attributes

This model was added by: LabWrenchSiteAdmin

Edit Model

Centrifuge Type Microcentrifuge
Maximum Capacity 24 x 1.5/2.0 mL tubes
Maximum RCF 21130
Maximum Speed 15000 rpm
Noise Level < 51 dB
Orientation Benchtop
Refrigerated No_
Speed Range 100 to 15000 rpm
Depth 32 cm
Height 23 cm
Width 24 cm
Power Requirements 120 V, 50/60 Hz
Peak Power 250 W
Weight 29.5 lbs
Additional Specifications No. of rotors:      
4      
Acceleration time to max. speed:      
15s      
Braking time from max. speed:     
16s      

Features

Product features of Centrifuge 5424 and 5424 R   
  • Very compact size   
  • Very silent operation, even without the rotor lid   
  • Low access height – for easy loading and unloading of the centrifuge   
  • Can be equipped with four different rotors:   
    - Standard 24-place rotor, aerosol-tight   
    - 24-place rotor, aerosol-tight, PTFE coated for increased chemical resistance   
    - 18-place Kit rotor for processing spin-columns with open tube lids   
    - 4 × 8 PCR strip rotor   
  • Two different operation panel   
  • Rotary knobs for fast and easy setting of parameters   
  • Foil version for easier cleaning of the front panel   
  • Automatic lid opening following centrifuge run – prevents sample warming (can be optionally deactivated (only 5424))   
  • Separate Short-spin button – for fast and short spins   
  • SOFT-brake to protect delicate samples   
       
    Additional cooling features of refrigerated Centrifuge 5424 R   
  • Patented compressor technology minimizes vibrations – protects your precious sample!   
  • Temperature range: –9 °C to +40 °C   
  • Small footprint and low access height of 26 cm, as refrigeration unit is at the rear of the unit   
  • Maintains constant 4 °C at max. speed   
  • Fast Temp for rapid pre-cooling of the centrifuge within 8 minutes from ambient temperature 23 °C   
  • Continuous cooling maintains temperature when centrifugation process is not active
  • Photos

    • 5424 Series
    • 5424R
    • 5424
    5424 Series

    5424 Series

    Manuals and Resources

    Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

    Instrument Documents

    Picture of EPPENDORF 5424/5424R
    You'll see Eppendorf products used in all types of life science research and clinical testing settings—from basic laboratory applications to highly specialized...

    More about EPPENDORF

    Visit EPPENDORF

    Questions and Answers

    Recent Question Activity

    Ask a Question

    Err 6 on my 5424R Eppendorf

    I'm having problems with my 5424 R and was hoping you could help me out here. The centrifuge runs smoothly as long as it is spinning up or running normally, but as soon as it tries to break, Err 6 appears on the screen. I've already...

    Eppendorf 5424 centrifuge

    I am getting the error message 16 and the users manual does not really help as it just says restart.  This does not help.  Can someone please tell me how to open the case.    Thanks

    Error Code 6 immediately after hitting start

    Hi I have a eppendorf 5424 that shows an error 6 right after hitting start.  I doubt its due to overheating since it doesn't get a chance to start up.  I'm wondering if there is a short or something preventing engagment of the...

    See all 10 EPPENDORF 5424/5424R Questions and Answers There are 10 Threads

    Reviews

    Member Reviews

    There are no threads in EPPENDORF 5424/5424R Reviews at this time.
    Add a Review

    Buy it Used!

    Used EPPENDORF 5424/5424R Offerings on LabX

    Eppendorf 5424R Refrigerated Microcentrifuge with Warranty

    Price: Call Lab World Group

    Condition:

    Configuration: Complete System

    Eppendorf FA-45-24-11 Rotor for 5424

    Price: In Stock - contact Marshall

    Eppendorf FA-45-24-11 Rotor for 5424

    Price: In Stock - contact Marshall

    Find more results for "EPPENDORF 5424/5424R" models on LabX
    Advertisement

    Videos

    See it in action

    Microcentrifuge Model 5424

    The variable 24 place Eppendorf microcentrifuge with its four rotors fits perfectly into every molecular and biological lab.