Advertisement

Malvern Panalytical Kinexus

Share:

Kinexus

Kinexus is a unique rheometer designed for tomorrow's rheology needs across all industries and application areas. Designed from the ground up, the Kinexus rheology platform is the result of more than four years intensive product development. Kinexus enables you to precisely analyze the rheology, or flow and deformation properties of your materials

Models

Kinexus lab+
Attributes

This model was added by: LabWrenchSiteAdmin

Edit Model

Depth 485 mm
Height 680 mm
Width 490 mm
Weight 47 kg
Additional Specifications Torque range - viscometry 0.05µNm to 200mNm (continuous)
Torque range - oscillation 0.05µNm to 200mNm (continuous)
Torque resolution 0.1nNm
Position resolution<10nrad
Angular velocity range 10nrad/s to 500rad/s
Step change in strain <10ms
Frequency range 6.28µrad/s to 942rad/s (1µHz to 150Hz)
Motor inertia 13 µN.m.s
Normal force range 0.001N to 20N (50N optional)
Normal force response time <10ms
Vertical lift speed 0.1 µm/s to 35mm/s
Vertical lift range (measurable) 230mm
Gap resolution (over full range) 0.1 µm
Fully configurable vertical profiles By speed and normal force
Raw instrument variables 5kHz constant streaming data
Complete sample history Data available from loading to unloading
USB2 instrument interface Plug & play
Quick connect geometries Plug & play; auto-configuration
Cartridge environmental controllers Plug & play; auto-configuration
Plate environmental controller -40 to 200 ° C (0.01 ° C resolution)
Interchangeable lower plates Varying diameters & surface finishes
Cylinder environmental controller -30 to 200 ° C (0.01 ° C resolution)
Open frame and open base design Maximum space for accessory integration
Kinexus pro+
Attributes

This model was added by: LabWrenchSiteAdmin

Edit Model

Depth 485 mm
Height 680 mm
Width 490 mm
Power Requirements 110 V or 220V.
Weight 47 kg
Additional Specifications Standard operating modes: 
Direct strain control. 
Shear rate control. 
Shear stress control. 
Torque range (Viscometry - Controlled Rate and Controlled Stress): 
10nNm to 200mNm. 
Torque range (Oscillation - Controlled Strain and Controlled Stress): 
2nNm to 200mNm. 
Torque resolution: 
0.1nNm. 
Position resolution: 
<10nrad. 
Angular velocity range: 
10nrads-1 to 500rads-1 
Step change in strain: 
<10ms. 
Frequency range: 
6.28µrads-1 to 942rads-1 (1µHz to 150Hz). 
Motor inertia: 
13µN.m.s2. 
Normal Force range: 
0.001N to 20N (50N optional). 
Normal Force resolution: 
0.5mN. 
Normal Force response time: 
<10ms. 
Vertical lift speed: 
0.1µms-1 to 35mms-1 
Vertical lift range (measurable): 
230mm. 
Gap resolution (over full vertical lift range): 
0.1µm 
Fully configurable vertical profiles: 
By speed and by Normal Force. 
Raw instrument variables: 
5kHz constant streaming data. 
Complete sample history: 
Data available from loading to unloading as standard. 
Instrument interface: 
USB2 – plug and play. 
Temperature control range: 
-40°C to 200°C (Peltier plate and active hood cartridges). 
-30°C to 200°C (Peltier cylinder cartridge) 
Temperature resolution: 
0.01°C.
Kinexus ultra+
Attributes

This model was added by: LabWrenchSiteAdmin

Edit Model

Depth 485 mm
Height 680 mm
Width 490 mm
Power Requirements 110 V or 220V.
Weight 47 kg
Additional Specifications Standard operating modes:
Direct strain control.
Shear rate control.
Shear stress control.
Torque range (Viscometry - Controlled Rate and Controlled Stress):
5nNm to 250mNm.
Torque range (Oscillation - Controlled Strain and Controlled Stress):
0.5nNm to 250mNm.
Torque resolution:
0.05nNm.
Position resolution:
<10nrad.
Angular velocity range:
10nrads-1 to 500rads-1.
Step change in strain:
<10ms.
Frequency range:
6.28µrads-1 to 942rads-1 (1µHz to 150Hz).
Motor inertia:
13µN.m.s2.
Normal Force range:
0.001N to 20N (50N optional.)
Normal Force resolution:
0.5mN
Normal Force response time:
<10ms.
Vertical lift speed:
0.1µms-1 to 35mms-1.
Vertical lift range (measurable):
230mm.
Gap resolution (over full vertical lift range):
0.1µm
Fully configurable vertical profiles:
By speed and by Normal Force.
Raw instrument variables:
5kHz constant streaming data.
Complete sample history:
Data available from loading to unloading as standard.
Instrument interface:
USB2 – plug and play.
Quick-connect geometries:
Auto-identification and auto-configuration – plug and play.
Interchangeable lower plates:
Varying pedestal diameters and surface finishes.
Cartridge environmental controllers:
Auto-identification and auto-configuration – plug and play.
Temperature control range:
-40°C to 200°C (Peltier plate and active hood cartridges).
-30°C to 200°C (Peltier cylinder cartridge).
Temperature resolution:
0.01°C.

Features

Kinexus enables you to precisely analyze the rheology, or flow and deformation properties of your materials:  
      
  • from liquids to solids.  
  • from processability to product performance.  
  • from temperature to time dependence.  
  • from simple viscosity to complex viscoelastic parameters.  
      

Photos

  • Kinexus
  • Kinexus pro+
  • Kinexus ultra+
Kinexus

Kinexus

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Picture of Malvern Panalytical Kinexus
Malvern Panalytical provides materials and biophysical characterization technology and expertise.

Malvern Panalytical was formed by the merger of...

More about Malvern Panalytical

Visit Malvern Panalytical

Questions and Answers

Recent Question Activity

Ask a Question

Problems with Newtonian linear fit

Hello all, We recently received a new Kinexus pro. Now, we are running the software and everything works well. However, when I try to analyze the post-results. Of a test, having a shear ramp at constant Temp. The software does not gives me...

There are 1 Threads

Reviews

Member Reviews

There are no threads in Malvern Panalytical Kinexus Reviews at this time.
Add a Review