| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Dispensing Volume Range | .1 to 1 µL |
| Increment | .001 µL |
| Maximum Dispensing Volume | 1 µL |
| Pipette Accuracy | ±2% |
| Pipette Precision | ±1.2% |
| Pipette Type | Electronic Air Displacement |
| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Dispensing Volume Range | .5 to 10 µL |
| Increment | .01 µL |
| Maximum Dispensing Volume | 10 µL |
| Pipette Accuracy | ±1% |
| Pipette Precision | 0.5% |
| Pipette Type | Electronic Air Displacement |
| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Dispensing Volume Range | 2 to 20 µL |
| Increment | .02 µL |
| Maximum Dispensing Volume | 20 µL |
| Pipette Accuracy | ±0.8% |
| Pipette Precision | 0.4% |
| Pipette Type | Electronic Air Displacement |
| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Dispensing Volume Range | 10 to 100 µL |
| Increment | .1 µL |
| Maximum Dispensing Volume | 100 µL |
| Pipette Accuracy | ±0.6% |
| Pipette Precision | 0.2% |
| Pipette Type | Electronic Air Displacement |
| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Dispensing Volume Range | 100 to 1000 µL |
| Increment | 1 µL |
| Maximum Dispensing Volume | 1000 µL |
| Pipette Accuracy | ±0.6% |
| Pipette Precision | 0.2% |
| Pipette Type | Electronic Air Displacement |
| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Dispensing Volume Range | 500 to 5000 µL |
| Increment | 5 µL |
| Maximum Dispensing Volume | 5000 µL |
| Pipette Accuracy | ±0.6% |
| Pipette Precision | 0.2% |
| Pipette Type | Electronic Air Displacement |
| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Dispensing Volume Range | 1000 to 10000 µL |
| Increment | 10 µL |
| Maximum Dispensing Volume | 10000 µL |
| Pipette Accuracy | ±0.6% |
| Pipette Precision | 0.2% |
| Pipette Type | Electronic Air Displacement |
| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Maximum Dispensing Volume | 10 µL |
| Pipette Accuracy | ±1% |
| Pipette Precision | 0.5% |
| Pipette Type | Electronic Air Displacement |
| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Maximum Dispensing Volume | 20 µL |
| Pipette Accuracy | ±0.8% |
| Pipette Precision | 0.4% |
| Pipette Type | Electronic Air Displacement |
| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Maximum Dispensing Volume | 25 µL |
| Pipette Accuracy | ±0.8% |
| Pipette Precision | 0.4% |
| Pipette Type | Electronic Air Displacement |
| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Maximum Dispensing Volume | 50 µL |
| Pipette Accuracy | ±0.8% |
| Pipette Precision | 0.4% |
| Pipette Type | Electronic Air Displacement |
| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Maximum Dispensing Volume | 100 µL |
| Pipette Accuracy | ±0.6% |
| Pipette Precision | 0.2% |
| Pipette Type | Electronic Air Displacement |
| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Maximum Dispensing Volume | 200 µL |
| Pipette Accuracy | ±0.6% |
| Pipette Precision | 0.2% |
| Pipette Type | Electronic Air Displacement |
| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Maximum Dispensing Volume | 500 µL |
| Pipette Accuracy | ±0.6% |
| Pipette Precision | 0.2% |
| Pipette Type | Electronic Air Displacement |
| Attributes | |
|---|---|
|
This model was added by: WrenchAdmin2 |
|
| Channel(s) | 1 |
| Maximum Dispensing Volume | 1000 µL |
| Pipette Accuracy | ±0.6% |
| Pipette Precision | 0.2% |
| Pipette Type | Electronic Air Displacement |