Advertisement

Rudolph Research Analytical Autopol VII

Share:

Autopol VII

High Accuracy Polarimeter with Industry Leading Automated Sample Loading 
The Industry Standard Polarimeter 
The Autopol® VII combines a pharmaceutical level Polarimeter with fully automated sample loading capability, a perfect answer for high throughput labs that demand accuracy and, reproducibility, combined with versatile sample loading, cell cleaning, rinsing, and drying. 
 
The Autopol® VII has the validation tools, features, and reputation to satisfy today’s global pharmaceutical companies, including: instrument level 21CFR Part 11 compliance, NIST traceable validation and a global list of satisfied customers who praise the Autopol’s® quality, accuracy and reproducibility. 
 
The Autopol® VII offers Automated NIST Traceable 3 point validation combined with fully Automatic TempTrolTM Temperature Control 
The Autopol® VII has built-in NIST Traceable Quartz plates to automatically perform a 3 rotation validation on the Autopol VII. To validate the instrument simply press a button to begin the validation routine. Using the on-board quartz plate standards the instrument will perform and record the results of a full 3 point calibration at all wavelengths at the correct temperature.
Autopol VII
Attributes
Additional Specifications Measuring Mode:  
Optical Rotation, Specific Rotation, Concentration & User-defined Scales 
Measuring Scale: 
Degrees Arc, % Concentration 
Measuring Range:  
±89.9° Arc Optical Rotation, ±999.99° Arc Specific Rotation and 0-99.9% Concentration 
Resolution:  
0.001° Arc Optical Rotation, 0.001% Concentration, 0.001° Specific Rotation 
Reproducibility:  
0.002° Arc 
Standard Model Accuracy:  
0.002° up to 1°, 0.2% up to 5°, 0.01° above 5° 
AP Model Accuracy:  
(546nm and 589nm): ±0.002° Arc over ±89.9°?Arc. Accuracy for other wavelengths is the same as the standard model. 
Prism:  
Glan Thompson calcite quartz 
Optical Wavelengths:  
365nm, 405nm, 436nm, 546nm, 589nm, 633nm (other wavelengths available) 
Wavelength Selection:  
Automatic by push-button 
TempTrol™ Range:  
Automatic Electronic Heating & Cooling 15°-35°C 
TempTrol™ Accuracy:  
±0.2°C 
Temp. Probe Range:  
10°-40°C 
Temp. Probe Accuracy:  
±0.1°C 
Acid Resistance:  
Hastelloy™ measurement cell and Silco Steel™ sample chamber (optional) 
Measurement Time:  
4°/sec. slew rate and 5 sec. nominal settling time 
Light Source:  
Tungsten-halogen 6V, 20W, avg. 2,000 hour life 
Sample Chamber:  
Accepts sample tubes up to 200mm 
Data Storage/Internal Memory:  
Multimedia Card and/or Secure Digital Card 
Communication Interface:  
Two RS232 serial ports, one parallel printer port and one auxiliary port 
Calibration:  
Automatic calibration by push-button 
Display:  
7.5cm x 10cm graphics LCD, 320 x 240 dots cold fluorescent back lit 
User Interface:  
Touchscreen 
Automatic Sensitivity Control:  
Measures samples with transmittance as low as 0.01% (up to O.D. 4.0) 
Input Power:  
100-240VAC, 50/60 Hz 
Operating Dimensions:  
35”W x 10.5”H x 17”D 890mm W x 267mm H x 432mm D 
Shipping Dimensions:  
43”W x 26”H x 23”D 1,025mm W x 625mm H x 625mm D 
Operating Weight:  
85 lbs. (39kg) 
Shipping Weight:  
115 lbs. (52kg)

Features

Automated filling, cleaning, and rinsing 
 
The Autopol VII with integrated sample loading 
can be configured to automate a wide range of sample viscosities. Perfect for high throughput laboratories looking to increase productivity. By automating sample loading user time is saved. The method ensures samples are loaded properly and the correct cleaning and rinsing sequence is performed. The Autopol® VII with integrated automated sample loading is ideal for busy Pharmaceutical laboratories where sample 
handling is discouraged. 
 
Sample Viscosity: 
 
• Samples up to 36,000 mPa-s (cP) 
 
• Sample Volume Requirements: 3.5ml typical, optional to 1.5ml 
 
Rack Sample Capacity: 
 
• 50 – 16 x 100mm Test tubes. 70 – 13 x 100 mm, or  
optionally dozens of sample vial configurations and 
capacities. 
 
Cleaning Cycle: 
 
• 1:45 minutes nominal – Time varies by application 
 
• Full Measurement and Cleaning Cycle: 2:30 minutes nominal – Time varies by application

Photos

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Picture of Rudolph Research Analytical Autopol VII
For over fifty years Rudolph has dedicated itself to manufacturing quality instruments and providing superior technical and service support. With over...

More about Rudolph Research Analytical

Visit Rudolph Research Analytical

Questions and Answers

Recent Question Activity

Be the first to Ask a Question

Reviews

Member Reviews

There are no threads in Rudolph Research Analytical Autopol VII Reviews at this time.
Add a Review

Buy it Used!

Used Rudolph Research Analytical Autopol VII Offerings on LabX

Rudolph Research Analytical Autopol IV Automatic Polarimeter Model APIV/6W

Price: $3,395.00

Condition:

Configuration: As Shown

Advertisement