Advertisement

GE Healthcare AKTA Explorer

Share:

AKTA Explorer

ÄKTAexplorer™ chromotography systems are designed for fast development and optimization of any biomolecular purification, using one working platform for all techniques and samples. The method wizard and optimized system configurations, allow rapid media screening, method scouting, method optimization, and scale-up experiments. Standard system configurations are available to suit most purification needs, but are easily modified if required. Systems can be used at flow rates up to 100 ml/min (pressure 10 MPa) to ensure minimized run times at maximum flow rates or at 10 ml/min (pressure 25 MPa) for applications routinely using columns that generate higher backpressures. Preparation times are minimized while accuracy and reproducibility of results are assured. 
 
ÄKTAexplorer has been discontinued and is replaced with ÄKTA avant.

Features

Photos

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Picture of GE Healthcare AKTA Explorer
GE Healthcare provides transformational medical technologies and services that are shaping a new age of patient care. Our broad expertise in medical imaging...

More about GE Healthcare

Visit GE Healthcare

Questions and Answers

Recent Question Activity

Ask a Question

change lamp but message warning low light

hello I changed the lamp on our akta explorer but I still have the warning low light message. I want to go to the mode service but I can't find where to put the code. to reset the lamp hours thank you for your help best...

change lamp but warning low light message.

Hello I changed the lamp on our akta explorer but I still have the warning low light message. I want to go to the mode service but I can't find where to put the code. to reset the lamp hours thank you for your help   Best...

Aekta Explorer P-900 Synchronization

Hi; When I start up the equipment, the pump request synchronization. As result of the process I receive an error message and a request to restart the pump, which brings me to the same result, namely an error, What can I do? Any suggestions?

See all 4 GE Healthcare AKTA Explorer Questions and Answers There are 4 Threads

Reviews

Member Reviews

There are no threads in GE Healthcare AKTA Explorer Reviews at this time.
Add a Review

Buy it Used!

Used GE Healthcare AKTA Explorer Offerings on LabX

AKTA FPLC Amersham Biosciences w/Computer & Software

Price: $9,625.00

Condition:

Configuration: As Shown

AKTA FPLC Amersham Biosciences w/Computer & Software

Price: $9,625.00

Condition:

Configuration: As Shown

R160998 GE AKTA Avant FPLC ELM-005 Electrode

Price: $50.00

Condition:

Configuration: As Shown

GE HEALTHCARE LIFE SCIENCE A-905 A 905 AUTOSAMPLER FOR AKTA MICRO

Price: $650.00

Condition:

Configuration: As Shown

GE AKTA FPLC Explorer 10 System

Price: $20,595.00

Condition:

Configuration: Complete System

GE AKTA FPLC Explorer Air 100 System

Price: $23,295.00

Condition:

Configuration: Complete System

Find more results for "GE Healthcare AKTA Explorer" on LabX