PerkinElmer LAMBDA 25/35/45

Share:

LAMBDA 25/35/45

PerkinElmer's LAMBDA 25/35/45 UV/Vis systems are easy to operate and deliver trustworthy results with the minimum of operator training. With over 12,000 units installed worldwide, our superior technology and proven build quality has proven itself under the toughest conditions. Our extensive suite of Instrument Performance Verification (IPV) tests confirms high quality performance over the lifetime of the system, and for regulated industries the Enhanced Security (ES) version of UV WinLab integrates seamless 21CFR part 11 technical compliance.    
    
For fast and reliable results time after time, choose the LAMBDA 25 for routine UV/Vis applications, pharmacopoeia and regulatory tests and liquids analysis. The comprehensive range of operating modes provides trustworthy results for a range of analyses including quantitative measurements and kinetics studies.    
    
Choose the LAMBDA 35 for measurements on liquids, solids, pastes and powder samples, also regulatory tests requiring variable resolution. The variable bandwidth operation allows sensitive measurements with accessories such as integrating spheres and fiber-optics probes, extending the range of samples that can be analyzed.    
    
Choose the LAMBDA 45 for measurements on liquids samples, regulatory tests requiring variable resolution, and highly light-scattering samples. The additional pre-monochromator reduces stray light by a factor of 2, providing optimum performance for turbid and light-scattering samples, such as some biological solutions and suspensions.

Models

LAMBDA 25
Attributes

This model was added by: WrenchAdmin2

Edit Model

Bandwidth 1 nm fixed
Light Source Deuterium and Tungsten prealigned sources with automatic switch-over
Optics Double Beam
Photometric Noise at 500 nm (RMS): Noise 500 nm/0 A RMS, Slit 1 nm: < 0.00005 A
Wavelength Range 190 to 1100 nm
Depth 22 in
Height 9 in
Width 25 in
Weight 57 lbs
Additional Specifications Stray light:
At 220 nm (NaI): < 0.01%T
At 340 nm (NaNO2): < 0.01%T
At 370 nm (NaNO2): < 0.01%T
At 200 nm (KCl): < 1%T
Wavelength accuracy:
At D2 peak (656.1 nm): ±0.1 nm
Wavelength reproducibility:
10 measurements at 656.1 nm: ±0.05 nm
Photometric accuracy:
At 1 A using NIST 930D filter: ±0.001 A
At 2 A using NIST 1930D filter: ±0.005 A
Potassium dichromate: ±0.010 A
Photometric reproducibility:
Maximum deviation of 10 measurements at 1 A: < 0.001 A
Photometric stability:
Stability at 1 A, at 500 nm with 2-sec. response time: < 0.00015 A/hour
Baseline flatness: Slit 1 nm: ±0.001 A
Construction: Solid CNC-machined aluminum chassis for thermal and vibration stability
Grating: Holographic, concave grating with 1053 lines per mm
LAMBDA 35
Attributes

This model was added by: WrenchAdmin2

Edit Model

Bandwidth 0.5, 1, 2, 4 nm variable
Light Source Deuterium and Tungsten prealigned sources with automatic switch-over
Optics Double Beam
Photometric Noise at 500 nm (RMS): Noise 500 nm/0 A RMS, Slit 1 nm: < 0.00005 A
Wavelength Range 190 to 1100 nm
Depth 22 in
Height 9 in
Width 25 in
Weight 57 lbs
Additional Specifications Stray light:
At 220 nm (NaI): < 0.01%T
At 340 nm (NaNO2): < 0.01%T
At 370 nm (NaNO2): < 0.01%T
At 200 nm (KCl): < 1%T
Wavelength accuracy:
At D2 peak (656.1 nm): ±0.1 nm
Wavelength reproducibility:
10 measurements at 656.1 nm: ±0.05 nm
Photometric accuracy:
At 1 A using NIST 930D filter: ±0.001 A
At 2 A using NIST 1930D filter: ±0.005 A
Potassium dichromate: ±0.010 A
Photometric reproducibility:
Maximum deviation of 10 measurements at 1 A: < 0.001 A
Photometric stability:
Stability at 1 A, at 500 nm with 2-sec. response time: < 0.00015 A/hour
Baseline flatness: Slit 1 nm: ±0.001 A
Construction: Solid CNC-machined aluminum chassis for thermal and vibration stability
Grating: Holographic, concave grating with 1053 lines per mm
LAMBDA 45
Attributes

This model was added by: WrenchAdmin2

Edit Model

Bandwidth 0.5, 1, 2, 4 nm variable
Light Source Deuterium and Tungsten prealigned sources with automatic switch-over
Optics Double Beam
Photometric Noise at 500 nm (RMS): Noise 500 nm/0 A RMS, Slit 1 nm: < 0.00005 A
Wavelength Range 190 to 1100 nm
Depth 22 in
Height 9 in
Width 25 in
Weight 57 lbs
Additional Specifications Stray light:
At 220 nm (NaI): < 0.05%T
At 340 nm (NaNO2): < 0.05%T
At 370 nm (NaNO2): < 0.05%T
At 200 nm (KCl): < 1%T
Wavelength accuracy:
At D2 peak (656.1 nm): ±0.1 nm
Wavelength reproducibility:
10 measurements at 656.1 nm: ±0.05 nm
Photometric accuracy:
At 1 A using NIST 930D filter: ±0.001 A
At 2 A using NIST 1930D filter: ±0.005 A
Potassium dichromate: ±0.010 A
Photometric reproducibility:
Maximum deviation of 10 measurements at 1 A: < 0.001 A
Photometric stability:
Stability at 1 A, at 500 nm with 2-sec. response time: < 0.00015 A/hour
Baseline flatness: Slit 1 nm: ±0.001 A
Construction: Solid CNC-machined aluminum chassis for thermal and vibration stability
Grating: Holographic, concave grating with 1053 lines per mm

Features

        
  • True double-beam operation    
  • High throughput, low stray-light optics    
  • Pre-aligned deuterium and tungsten-halogen lamps    
  • Wide range of accessories and consumables    
  • Choice of UV WinLab software    
    
Benefits    
        
  • Very high stability, high accuracy and reproducibility.    
  • Easily passes all pharmacopoeia and regulatory performance tests    
  • Quickly replaced for minimal downtime    
  • Perfect for any liquid sample    
  • Select the version that best matches your analysis needs and the skill level of your operators.    
    
Applications    
        
  • Routine UV/Vis testing    
  • Liquids analysis    
  • Pharmacopeia and regulatory tests (LAMBDA 25)    
  • Solids, pastes and powder samples (LAMBA 35/45)    
  • Regulatory tests requiring variable bandwidths (LAMBDA 35/45)    
  • Highly scattering samples (LAMBDA 45)    

Photos

Lambda 25

Lambda 25

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Picture of PerkinElmer LAMBDA 25/35/45
Improving human and environmental health is their focus. From earlier insights and more effective therapies to cleaner water and safer buildings where...

More about PerkinElmer

Visit PerkinElmer

Questions and Answers

Recent Question Activity

Ask a Question

lambda 35 uv vis spec filters

I need filters for lambda 35 and I dont know where to buy it. Please help

qualification of Lambda 20 and Lambda 25

How to  Base line noise test  and Photometric drift test at Lambda 20 and Lambda 25 Spectrophotometer? Please advice. thank you

lambda 20 software

       our  control computer crashed, and we need to re-install the software for the lambda 20.  Where can we get a copy?   Scott

See all 21 PerkinElmer LAMBDA 25/35/45 Questions and Answers There are 21 Threads

Reviews

Member Reviews

There are no threads in PerkinElmer LAMBDA 25/35/45 Reviews at this time.
Add a Review

Buy it Used!

Used PerkinElmer LAMBDA 25/35/45 Offerings on LabX

PERKIN ELMER LAMBDA 6 UV/VIS SPECTROMETER

Price: $250.00

Condition:

Configuration: As Shown

PERKIN ELMER LAMBDA2S LAMBDA 2S UV/VIS SPECTROMETER

Price: $520.00

Condition:

Configuration: As Shown

Perkin Elmer L6009015C Main Board for Perkin Elmer Lambda 25/35/45

Price: $950.00

Condition:

Configuration: As Shown

R146853 Perkin Elmer Lambda 35 UV/VIS Spectrometer w/ Many Accessories

Price: $3,000.00

Condition:

Configuration: As Shown

Perkin Elmer Lambda 35 UV-Visible Spectrometer

Price: $6,300.00

Condition:

Configuration: As Shown