Bruker Optics Diffusion

Share:

Diffusion

The Diff30 and Diff50 probes are made for standard bore and wide bore magnets respectively. They consist of a probe body, a plug on gradient system and exchangeable rf-coils. The rf-coils can be single or double tuned with diameters between of 5, 8 and 10 mm.     
     
The z-gradient diffusion probes Diff30 and Diff50 and the xyz triple axis Micro5 micro-imaging probe differ only by the plug on gradient system. This enables an easy switch between micro-imaging and diffusion experiments, just by mounting the required gradient system on the same probe body. The exchangeable rf-coils are compatible between the probes.

Models

Diff30
Attributes

Edit Model

Additional Specifications Diff30 Gradient properties
Name: Diff30
Gradient system part number: M81113
Type: Diffusion probe
Compatibility with magnet systems: SB/WB/SWB
Gradient Direction: z
Theoretical gradient sensitivity: 30 G/cm/A, 300 mT/m/A, 0.3 T/m/A
Typical gradient strength @ 40 A: > 1140 G/cm, > 11400 mT/m, > 11.4 T/m
Typical gradient strength @ 60 A: > 1710 G/cm, > 17100 mT/m, > 17.1 T/m
ID/OD: 19/40 mm
Peak-peak deviation from constant gradient in a cylinder of 5 mm diameter and 14 mm length: < 2.5 %
Inductance: ? 180 ΜH
Resistance: ? 1.04 Ω
Rise time 10 - 90 % of 40 A, 120V using a GREAT40 amplifier: ? 300 Μs
Cooling: water
Maximum current tested: 60 A
Maximum pulse length at maximum current: 5 ms
Maximum dc current, at different cooling water temperatures, flow rate ? 0.5 l/min: 6.2 A @ 12 °C, 5.3 A @ 25 °C, 4.0 A @ 40 °C
Duty cycles with water cooling at 25° C, averaged over 1s.: 1.3 % @ 40 A, 0.57 % @ 60 A

Diff30 RF properties
Exchangeable coils:
Single frequency coils, sample diameters 5, 8, 10 mm: 1H or 19F or 1H to 19F tuneable or X nuclei above 40 MHz4
Double frequency coils, sample diameters 5, 8 mm, can be built in direct or inverse detection mode:
  • 1H channel: 1H or 19F or 1H to 19F tuneable
  • X channel: X nuclei above 40 MHz2

    Diff30 Temperature properties
    Standard coils, sample diameter = 5 mm
    Specified temperature range: -40 °C – 80 °C, 233 K – 353 K
    Safety limit: -100 °C – 80 °C, 173 K – 353 K
    Standard coils, sample diameter >5 mm
    Specified temperature range: Ambient temperature, i.e. gradient water cooling temperature
    Safety limit: -100 °C – 60 °C, 173 K – 333 K
    Note: Safety limits are only valid, while the cooling water is running at a water temperature between 5 °C and 50 °C
  • Diff50
    Attributes

    Edit Model

    Additional Specifications Diff50 Gradient properties
    Name: Diff50
    Gradient system part number: W122305
    Type: Diffusion probe
    Compatibility with magnet systems: WB/SWB
    Gradient Direction: z
    Theoretical gradient sensitivity: 50 G/cm/A, 500 mT/m/A, 0.5 T/m/A
    Typical gradient strength @ 40 A: > 1900 G/cm, > 19000 mT/m/m, > 19 T/m
    Typical gradient strength @ 60 A: > 2850 G/cm, > 28500 mT/m, > 28.5 T/m
    ID/OD: 19/72 mm
    Peak-peak deviation from constant gradient in a cylinder of 5 mm diameter and 14 mm length: < 5 %
    Inductance: ? 540 ΜH
    Resistance: ? 830 mΩ
    Rise time 10 - 90 % of 40 A, 120V using a GREAT40 amplifier: ? 500 Μs
    Cooling: water
    Maximum current tested: 60 A
    Maximum pulse length at maximum current: 5 ms
    Maximum dc current, at different cooling water temperatures, flow rate ? 0.5 l/min: 6 A @ 12 °C, 5.1 A @ 25 °C, 3.8 A @ 40 °C
    Duty cycles with water cooling at 25° C, averaged over 1s.: 1.1 % @ 40 A, 0.52 % @ 60 A

    Diff50 RF properties
    Exchangeable coils:
    Single frequency coils, sample diameters 5, 8, 10 mm: 1H or 19F or 1H to 19F tuneable or X nuclei above 40 MHz4
    Double frequency coils, sample diameters 5, 8 mm, can be built in direct or inverse detection mode:
  • 1H channel: 1H or 19F or 1H to 19F tuneable
  • X channel: X nuclei above 40 MHz2

    Diff50 Temperature properties
    Standard coils, sample diameter = 5 mm
    Specified temperature range: -40 °C – 80 °C, 233 K – 353 K
    Safety limit: -100 °C – 80 °C, 173 K – 353 K
    Standard coils, sample diameter: >5 mm
    Specified temperature range: Ambient temperature, i.e. gradient water cooling temperature
    Safety limit: -100 °C – 60 °C, 173 K – 333 K
    Note: Safety limits are only valid, while the cooling water is running at a water temperature between 5 °C and 50 °C
  • Features

    Photos

    Manuals and Resources

    Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

    Picture of Bruker Optics Diffusion
    Bruker Optics, part of the Bruker Corporation is the leading manufacturer and worldwide supplier of Fourier Transform Infrared, Near Infrared and Raman...

    More about Bruker Optics

    Visit Bruker Optics

    Questions and Answers

    Recent Question Activity

    Be the first to Ask a Question

    Reviews

    Member Reviews

    There are no threads in Bruker Optics Diffusion Reviews at this time.
    Add a Review

    Advertisement