Advertisement

Waters Prep SFC 100

Share:

Prep SFC 100

Purification scientists around the globe are excited by the latest advancements in supercritical fluid chromatography, or SFC, that are now backed by the powerful support of Waters. Since SFC uses CO2 as its main solvent, it is a critically important solution for purification laboratories that want to be more green. And SFC means much less time and money spent on both. Which is good for science, and good for the world we live in.  
  
Offering seamless, mass-triggered purification, the SFC/MS Prep 100 mass-directed purification system is the automated way to improve laboratory efficiency and turn-around times by virtually eliminating solvent disposal and clean-up.  
  
The SFC Prep 100 system utilizes high pressure CO2 as the primary mobile phase resulting in faster equilibration, lower pressure drops, solvent reduction and lower cost per sample. The process is gentle on the stationary phase, reproducible, and applicable to a wide range of compounds. The system can also be configured for UV-directed purification.

Features

      
  • Faster turnaround times  
  • Acetonitrile-free chromatography  
  • Uses MS or UV to trigger fraction collection  
  • Scalable from analytical to preparative  
  • New patent-pending flow splitter and gas/liquid separator  
  • Automated sample handling and column switching  
  • MassLynx Software and FractionLynx Application Manager combined with the power of AutoPurify further streamlines the isolation and purification process  
  
UV-Directed Purification with SFC  
  
When fraction collection is based on UV absorbance, multiple fractions may result, requiring further analysis to determine the fraction of interest. With the SFC 100 System, run samples around the clock with unprecedented versatility and consistency. Upgrading the capability of the UV-directed system to mass-directed is available for enhanced selectivity and capability.  
  
embeded Image: http://www.waters.com/webassets/cms/category/media/detail_page_images/AutoPur_UV-Diagram.jpg  
  
MS-Directed Purification with SFC  
  
When fraction collection is triggered by mass detection, fewer fractions result since you collect only the peak containing the mass of interest. The SFC/MS 100 System provides you with the flexibility of using high-throughput selective mass-directed fraction collection from hundreds of samples.  
  
Built around the 3100 Mass Detector, a compact, single quadrupole, atmospheric pressure ionization mass detector, the SFC/MS 100 System is designed for everyday mass-directed purification applications. The system's fluidics layout, enhanced software features, and hardware capabilities combine with OBD Column Technology for simplified operation.  
  
For those carrying out purification in an open access environment, the Fractionlynx Application Manager combined with AutoPurify further streamlines the isolation and purification process. AutoPurify allows laboratories to automate the purification process by linking the analytical pre–screen, (performed on a separate analytical SFC system), purification, and fraction analysis (performed on a separate analytical SFC system). By using the analytical pre–screen information, the system can optimize the purification run to reduce the run time, reduce the solvent usage, and enhance the quality of the collected fraction.  
  
embeded Image: http://www.waters.com/webassets/cms/category/media/detail_page_images/AutoPurif_MS-Systems_det3.jpg

Photos

Prep SFC 100

Prep SFC 100

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Picture of Waters Prep SFC 100
For more than 50 years, Waters Corporation has created business advantages for laboratory-dependent organizations by delivering practical and sustainable...

More about Waters

Visit Waters

Questions and Answers

Recent Question Activity

Ask a Question

consumption of compressed air

how much cubic per minute of compressed air does SFC-100 need ?

There are 1 Threads

Reviews

Member Reviews

There are no threads in Waters Prep SFC 100 Reviews at this time.
Add a Review

Buy it Used!

Used Waters Prep SFC 100 Offerings on LabX

MTA WATER CHILLER MODEL TAE EVO M03 - PARTS (#3134)

Price: $500.00

Condition:

Configuration: As Shown

Agilent 1100 Series Preparative Prep HPLC System -G2260A, G1361A, G1364B, G1315A

Price: $26,997.97

Condition:

Configuration: As Shown

Varian ProStar 330 Prep Scale PDA Detector Photodiode Array Detector

Price: $999.00

Condition:

Configuration: As Shown

WATERS CAPLC AUTOSAMPLER / MICROMASS CAPLC PUMP (#3027)

Price: $2,500.00

Condition:

Configuration: As Shown

Thermo Separation Products UV3000

Price: $2,200.00

Condition:

Configuration: As Shown

Forma Scientific CO2 Water Jacketed Incubator MODEL #3130 (#2821)

Price: $400.00

Condition:

Configuration: As Shown

Find more results for "Waters Prep SFC 100" on LabX