The electronic pipettes Eppendorf Xplorer and Eppendorf Xplorer plus were specially designed for high professional standards to provide optimal support for you in your work, with a new intuitive operating concept and design based on the proven Eppendorf PhysioCare® Concept. These features set new standards for simplicity, precision and reproducibility, which mean no more delays due to complicated programming or inflexible processes. Instead, you get precisely adjustable parameters, maximally reproducible results, fatigue-free work and full control over the pipetting processes.   
   
Xplorer plus   
With the additional intelligent applications, adjustable fixed-volumes and individual programming tasks are performed much faster and easier. The Xplorer plus also includes a history function that automatically saves the last parameters for faster handling! A password can be entered to guarantee the highest degree of protection for your programming and settings. On an integrated information display, you can see if your test series is correct or check when the next service is due. The Xplorer plus can remind you of its next service – after a specific period of time or depending on frequency of use as selected. The extended version of the Eppendorf Xplorer is the perfect choice for all users who simply need a little extra – more safety and speed every day!

Models

1-ch, 0.5-10 µL
Attributes

Edit Model

Channel(s) 1
Dispensing Volume Range .5 to 10 μL
Maximum Dispensing Volume 10 μL
Pipette Accuracy ±2.5% 1 ?L, ±1.5% 5 ?L, ±1.0% 10 ?L
Pipette Precision 1.8% 1 ?L, 0.8% 5 ?L, 0.4% 10 ?L
Pipette Type Electronic Air Displacement
Pipette Volume Type Variable
Additional Specifications Colour: Medium gray
1-ch, 5-100 µL
Attributes

Edit Model

Channel(s) 1
Dispensing Volume Range 5 to 100 μL
Maximum Dispensing Volume 100 μL
Pipette Accuracy ±2.0% 10 ?L, ±1.0% 50 ?L, ±0.8% 100 ?L
Pipette Precision 1.0% 10 ?L, 0.3% 50 ?L, 0.2% 100 ?L
Pipette Type Electronic Air Displacement
Pipette Volume Type Variable
Additional Specifications Colour: Yellow
1-ch, 15-300 µL
Attributes

Edit Model

Channel(s) 1
Dispensing Volume Range 15 to 300 μL
Maximum Dispensing Volume 300 μL
Pipette Accuracy ±2.0=5% 30 ?L, ±1.0% 150 ?L, ±0.6% 300 ?L
Pipette Precision 0.7% 30 ?L, 0.3% 150 ?L, 0.2% 300 ?L
Pipette Type Electronic Air Displacement
Pipette Volume Type Variable
Additional Specifications Colour: Orange
1-ch, 50-1,000 µL
Attributes

Edit Model

Channel(s) 1
Dispensing Volume Range 50 to 1000 μL
Maximum Dispensing Volume 1000 μL
Pipette Accuracy ±3.0% 100 ?L, ±1.0% 500 ?L, ±0.6% 1,000 ?L
Pipette Precision 0.6% 100 ?L, 0.2% 500 ?L, 0.2% 1,000 ?L
Pipette Type Electronic Air Displacement
Pipette Volume Type Variable
Additional Specifications Colour: Blue
1-ch, 0.25-5 mL
Attributes

Edit Model

Channel(s) 1
Dispensing Volume Range .25 to 5 ml
Maximum Dispensing Volume 5 ml
Pipette Accuracy ±3.0% 500 ?L, ±1.2% 2,500 ?L, ±0.6% 5,000 ?L
Pipette Precision 0.6% 500 ?L, 0.3% 2,500 ?L, 0.15% 5,000 ?L
Pipette Type Electronic Air Displacement
Pipette Volume Type Variable
Additional Specifications Colour: Violet
1-ch, 0.5-10 mL
Attributes

Edit Model

Channel(s) 1
Dispensing Volume Range .5 to 10 ml
Maximum Dispensing Volume 10 ml
Pipette Accuracy ±3.0% 1,000 ?L, ±0.8% 5,000 ?L, ±0.6% 10,000 ?L
Pipette Precision 0.6% 1,000 ?L, 0.2% 5,000 ?L, 0.15% 10,000 ?L
Pipette Type Electronic Air Displacement
Pipette Volume Type Variable
Additional Specifications Colour: Turquoise
8-ch, 0.5-10 µL
Attributes

Edit Model

Channel(s) 8
Dispensing Volume Range .5 to 10 μL
Maximum Dispensing Volume 10 μL
Pipette Accuracy ±5.0% 1 ?L, ±1.5% 5 ?L, ±1.0% 10 ?L
Pipette Precision 3.0% 1 ?L, 0.8% 5 ?L, 0.4% 10 ?L
Pipette Type Electronic Air Displacement
Additional Specifications Colour: Medium gray
8-ch, 5-100 µL
Attributes

Edit Model

Channel(s) 8
Dispensing Volume Range 5 to 100 μL
Maximum Dispensing Volume 100 μL
Pipette Accuracy ±2.0% 10 μL, ±1.0% 50 μL, ±0.8% 100 μL
Pipette Precision 2.0% 10 μL, 0.8% 50 μL, 0.25% 100 μL
Pipette Type Electronic Air Displacement
Additional Specifications Colour: Yellow
8-ch, 15-300 µL
Attributes

Edit Model

Channel(s) 8
Dispensing Volume Range 15 to 300 μL
Maximum Dispensing Volume 300 μL
Pipette Accuracy ±2.5% 30 μL, ±1.0% 150 μL, ±0.6% 300 μL
Pipette Precision 1.0% 30 μL, 0.5% 150 μL, 0.25% 300 μL
Pipette Type Electronic Air Displacement
Additional Specifications Colour: Orange
8-ch, 50-1,200 µL
Attributes

Edit Model

Channel(s) 8
Dispensing Volume Range 50 to 1200 μL
Maximum Dispensing Volume 1200 μL
Pipette Accuracy ±6.0 % 120 μL, ±2.7% 600 μL, ±1.2% 1,200 μL
Pipette Precision 0.9% 120 μL, 0.4% 600 μL, 0.3% 1,200 μL
Pipette Type Electronic Air Displacement
Additional Specifications Colour: Green
12-ch, 0.5-10 µL
Attributes

Edit Model

Channel(s) 12
Dispensing Volume Range .5 to 10 μL
Maximum Dispensing Volume 10 μL
Pipette Accuracy ±5.0% 1 μL, ±1.5% 5 μL, ±1.0% 10 μL
Pipette Precision 3.0% 1 μL, 0.8% 5 μL, 0.4% 10 μL
Pipette Type Electronic Air Displacement
Additional Specifications Colour: Medium gray
12-ch, 5-100 µL
Attributes

Edit Model

Channel(s) 12
Dispensing Volume Range 5 to 100 μL
Maximum Dispensing Volume 100 μL
Pipette Accuracy ±2.0% 10 μL, ±1.0% 50 μL, ±0.8% 100 μL
Pipette Precision 2.0% 10 μL, 0.8% 50 μL, 0.25% 100 μL
Pipette Type Electronic Air Displacement
Additional Specifications Colour: Yellow
12-ch, 15-300 µL
Attributes

Edit Model

Channel(s) 12
Dispensing Volume Range 15 to 300 μL
Maximum Dispensing Volume 300 μL
Pipette Accuracy ±2.5% 30 μL, ±1.0% 150 μL, ±0.6% 300 μL
Pipette Precision 1.0% 30 μL, 0.5% 150 μL, 0.25% 300 μL
Pipette Type Electronic Air Displacement
Additional Specifications Colour: Orange

Features

  • Multifunctional rocker: "UP is up and down is down" principle        
  • Easy selection of all functions with the practical selection dial        
  • Operate in the language of your choice        
  • Clearly arranged color display        
  • No sub-menues        
  • Help function        
  • Innovative rocker: When the tip is ejected, the piston automatically returns to zero position        
           
    PhysioCare Concept         
  • Reduced weight        
  • Improved ergonomics        
  • Perfect balance        
  • Optimally angled pipette head        
  • Improved view & high resolution display        
  • Spring-loaded tip cone provides maximum tightness        
     
    Reliably reproducible results        
  • Tips always rest in the same position        
  • Volume & speed precisely und reproducibly adjustable        
  • Adjustable to your work environment and requirements        
     
    Pipetting modes 
     
    Autodispense 
    Dispense 
    Pipetting 
    Pipetting and mixing 
    Manual pipetting  
    Multi-aspirate (Xplorer plus only) 
    Dilution (Xplorer plus only) 
    Sequential pipetting (Xplorer plus only) 
    Sequential dispensing (Xplorer plus only) 
    Reverse pipetting (Xplorer plus only)
  • Photos

    Xplorer

    Xplorer

    Manuals and Resources

    Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

    Instrument Documents

    Picture of EPPENDORF Explorer/Xplorer plus
    You'll see Eppendorf products used in all types of life science research and clinical testing settings—from basic laboratory applications to highly specialized...

    More about EPPENDORF

    Visit EPPENDORF