Advertisement

METTLER TOLEDO T70

Share:

T70

Fexibility with a clear concept  
  
Besides the many advantages of the Titration Excellence line such as One Click Titration™, Plug & Play and method database, the T70 offers a number of other important features:
T70
Attributes
mV Range 0 to 2000 Ipol / Upol: 0 … 200 µA
mV Resolution 0.1 mV Upol: 0.1 µA
Titrator Type Potentiometric +KF
Depth 246 mm
Height 250 mm
Width 210 mm
Weight 4.3 kg
Additional Specifications Potentiometric sensor inputs  
Measurement range: ± 2000 mV  
Error limit: 0.2 mV  
Polarized Sensor input  
Error limit Ipol / Upol: 2.0 mV / 0.2 µA  
Current source range Ipol / Upol: 0 – 24 µA AC / 0 – 2000 mV AC  
Current source resolution Ipol / Upol: 0.1µA / 0.1mV  
Temperature sensor input PT1000  
Measuring range: -20...130°C  
Resolution: 0.1 °C  
Error limit: 0.2 °C  
Burette drive  
Burette resolution (for 10-mL burette): 0.5 µL (1/20’000 of the burette volume)  
Error limit: 0.2% of the burette volume  
Resolver resolution: 0.0625% of burette volume  
Filling time and discharge time: 20 s at 100% filling rate

Features

      
  • Extended method flexibility  
  • Upgradeability to T90  
  • Expandable to perform conductivity measurements  
  • Task List  

Photos

T70 Titrator

T70 Titrator

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Picture of METTLER TOLEDO T70
METTLER TOLEDO instruments are used in research, scientific and quality control labs, amongst many others in the pharmaceutical, chemical, food and cosmetics...

More about METTLER TOLEDO

Visit METTLER TOLEDO

Questions and Answers

Recent Question Activity

Ask a Question

Connecting RS-P26 printer

We have the RS-P26 printer and are trying to get it to comunicate with the T70 titrator. I have configureded all settings to match printer with titrator. Keep getting no connection message on printer. What should I try?

Does the T70 titrator have the capability to connect to a PC?

Does the T70 titrator have the capability to connect to a PC?

Dosing unit freezing

We have experienced our dosing units squealing and then freezing. It only happens on one of our titrators and we've had to replace the dosing unit 3 times in the last few years. It is the dosing unit that is used the most but the titrator...

See all 19 METTLER TOLEDO T70 Questions and Answers There are 19 Threads

Reviews

Member Reviews

There are no threads in METTLER TOLEDO T70 Reviews at this time.
Add a Review

Buy it Used!

Used METTLER TOLEDO T70 Offerings on LabX

Mettler Toledo T70 Titrator with 10 mL Burette, Stirrer, Electrodes, Tested

Price: $6,000.00

Condition:

Configuration: As Shown

Mettler Toledo T70 Titrator with 10 mL Burette, Stirrer, Electrodes, Tested

Price: $5,600.00

Condition:

Configuration: As Shown

Mettler Toledo T70 Tirator with Optional Dosing Unit and Burette

Price: $10,900.00

Condition:

Configuration: As Shown