Gradient Capability Yes
Row Uniformity ± .5 °C well-to-well (within row) within 30 sec of reaching target temperature
Gradient Accuracy ± .5 °C of programmed target at end rows, NIST-traceable
Gradient Range 30 to 99 °C
Temp. Differential Range 1 to 25 °C
Temperature Accuracy ± .5 °C of programmed target at 90°C, NIST-traceable
Temperature Uniformity ± .5 °C well-to-well within 30 sec of arrival at 90°C
Depth 17.5 in
Height 8 in
Width 9 in
Weight 22 lbs
Additional Specifications Sample capacity: 96 x 0.2 ml tubes or 96-well PCR plate  
Speed of ramping: Up to 2.5°C/sec  
Input power: 100–150 VAC, 50–60 Hz; 220–240 VAC, 50–60 Hz; 670 W maximum  
Display: 12 cm (4.7") high-resolution 1/4 VGA  
Ports: 1 USB  
Memory: 99 typical programs

Features

      
  • A 96-well reaction module designed for use with 0.2 ml tubes or plates  
  • Intuitive programming of temperatures, times, and protocol options  
  • A user-programmable sleep mode that saves power when the instrument is not in use  
  • Status and history of each run recorded in run and validation reports  
  • A self-adjusting heated lid that accommodates standard 0.2 ml thin-wall PCR tubes, strips, and plates  
  • Optional thermal gradient feature  

Photos

MyCycler™ Personal Thermal Cycler

MyCycler™ Personal Thermal Cycler

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Picture of Bio-Rad MyCycler Personal Thermal Cycler
Bio-Rad Laboratories has played a leading role in the advancement of scientific discovery for over 50 years by providing a broad range of innovative tools...

More about Bio-Rad

Visit Bio-Rad

Questions and Answers

Recent Question Activity

Ask a Question

Not turning on, have incoming power and fuses are good please help.

Hello,  One of the labs I work for came to me and asked me to help them diagnose their MyCycler Thermal Cycler because it was not turning on.  I checked the incoming power and that checked out fine.  I checked all the fuses, and...

Start failure

Message on the screen: Version....1.2A ready to update....

There are 2 Threads

Reviews

Member Reviews

There are no threads in Bio-Rad MyCycler Personal Thermal Cycler Reviews at this time.
Add a Review