Advertisement

EPPENDORF epMotion 5070

Share:

epMotion 5070

The epMotion 5070 is the most compact solution for accurate and reproducible automated pipetting. With four deck positions, it can hold tips, reagent reservoirs, single tubes, tube racks, micro-plates, or PCR plates with up to 384 wells.    
    
This makes the epMotion 5070 a perfect match for any routine application such as serial dilutions, reagent distribution, sample transfer from tubes to plates, and sample normalization. Due to its excellent accuracy, the epMotion 5070 sets the standard for automated pipetting and real-time PCR set-up. The epMotion 5070 enables set-ups with less reagent volume and excellent reproducibility – within and even across experiments!

Models

5075 LH
Attributes

This model was added by: WrenchAdmin2

Edit Model

Dispensing Type Integrated Workstation
Workstation Type Multi-function
Depth 25 in (61 cm) device
Height 27 in (67 cm) device
Width 43 in (107 cm) device
Power Requirements 100-130 or 200-240 V, 50/60 Hz, 700 W
Weight 188 lbs (85 kg); control panel: 3 lbs (1.2 kg)
Additional Specifications Labspace 
System: 
Width: 140 cm/56 in. 
Depth: 75 cm/30 in. 
 
Dimensions 
Control Panel: 
Width: 25 cm/10 in. 
Depth: 15 cm/6 in. 
Height: 11 cm/4.4 in. 
 
Detector 
Optical confocal infrared detector: contact-free detection of liquid level, tools used, labware worktables, tip types and quantities 
Optical sensor: liquid surface must be 90 +/- 3° to the vertical plane of the optical sensor 
 
Temperature Unit (optional) 
Setting range: 0 to 110°C 
Heating time of the heating-cooling plate: from 25 to 95°C in 8 minutes 
Cooling time of the heating-cooling plate: 25 to 4°C in 5 minutes 
 
Software 
Operating software: MotionManager V 1.6 or higher; Firmware: MotionInstrument V 1.6 or higher; Labware 0.5 or higher
5075 VAC
Attributes

This model was added by: WrenchAdmin2

Edit Model

Dispensing Type Integrated Workstation
Workstation Type SPE / LLE
Depth 25 in (61 cm) device
Height 27 in (67 cm) device
Width 43 in (107 cm) device
Power Requirements 100-130 or 200-240 V, 50/60 Hz, 700 W
Weight 90 kg (199 lbs) device; control panel: 1.2 kg (3 lbs)
Additional Specifications Labspace 
System: 
Width: 140 cm/56 in. 
Depth: 75 cm/30 in. 
 
Dimensions 
Control Panel: 
Width: 25 cm/10 in. 
Depth: 15 cm/6 in. 
Height: 11 cm/4.4 in. 
 
Detector 
Optical confocal infrared detector: contact-free detection of liquid level, tools used, labware worktables, tip types and quantities 
Optical sensor: liquid surface must be 90 +/- 3° to the vertical plane of the optical sensor 
 
Vacuum Unit 
Max. output: 35 L/min feed 
Suction range: 0.1 to 0.85 +/-0.05 hPa 
Suction time: 1-99 minutes 
 
Temperature Unit (optional) 
Setting range: 0 to 110°C 
Heating time of the heating-cooling plate: from 25 to 95°C in 8 minutes 
Cooling time of the heating-cooling plate: 25 to 4°C in 5 minutes 
 
Software 
Operating software: MotionManager V 1.6 or higher; Firmware: MotionInstrument V 1.6 or higher; Labware 0.5 or higher
5075 MC
Attributes

This model was added by: WrenchAdmin2

Edit Model

Dispensing Type Integrated Workstation
Workstation Type Nucleic Acid Prep / PCR
Depth 25 in (61 cm) device
Height 27 in (67 cm) device
Width 43 in (107 cm) device
Power Requirements 100-130 or 200-240 V, 50/60 Hz, 700 W
Weight 225 lbs (102 kg) device; control panel: 3 lbs (1.2 kg)
Additional Specifications Labspace 
System: 
Width: 140 cm/56 in. 
Depth: 75 cm/30 in. 
 
Dimensions 
Control Panel: 
Width: 25 cm/10 in. 
Depth: 15 cm/6 in. 
Height: 11 cm/4.4 in. 
 
Detector 
Optical confocal infrared detector: contact-free detection of liquid level, tools used, labware worktables, tip types and quantities 
Optical sensor: liquid surface must be 90 +/- 3° to the vertical plane of the optical sensor 
 
Cycler Unit 
Heating-cooling unit: 96 Al, 96 Ag, 385 Al 
 
Temperature Unit (optional) 
Setting range: 0 to 110°C 
Heating time of the heating-cooling plate: from 25 to 95°C in 8 minutes 
Cooling time of the heating-cooling plate: 25 to 4°C in 5 minutes 
 
Software 
Operating software: MotionManager V 1.6 or higher; Firmware: MotionInstrument V 1.6 or higher; Labware 0.5 or higher
5075 TMX
Attributes

This model was added by: WrenchAdmin2

Edit Model

Depth 25 in (61 cm) device
Height 27 in (67 cm) device
Width 43 in (107 cm) device
Power Requirements 100-130 or 200-240 V, 50/60 Hz, 1,000 W
Weight 188 lbs (85 kg) device; control panel: 3 lbs (1.2 kg)
Additional Specifications Labspace
System:
Width: 140 cm/56 in.
Depth: 75 cm/30 in.

Dimensions
Control Panel:
Width: 25 cm/10 in.
Depth: 15 cm/6 in.
Height: 11 cm/4.4 in.

Detector
Optical confocal infrared detector: contact-free detection of liquid level, tools used, labware worktables, tip types and quantities
Optical sensor: liquid surface must be 90 +/- 3° to the vertical plane of the optical sensor

Temperature Unit (optional)
Setting range: 0 to 110°C
Heating time of the heating-cooling plate: from 25 to 95°C in 8 minutes
Cooling time of the heating-cooling plate: 25 to 4°C in 5 minutes

Software
Operating software: MotionManager V 1.6 or higher; Firmware: MotionInstrument V 1.6 or higher; Labware 0.5 or higher
5070
Attributes

This model was added by: WrenchAdmin2

Edit Model

Depth 20 in (48 cm) device
Height 26 in (63 cm) device
Width 26 in (65 cm) device
Power Requirements 100-130 or 200-240 V, 50/60 Hz, 150 W
Weight 99 lbs (45 kg) device; control panel: 3 lbs (1.2 kg)
Additional Specifications Labspace
System:
Width: 140 cm/56 in.
Depth: 75 cm/30 in.

Dimensions
Control Panel:
Width: 25 cm/10 in.
Depth: 15 cm/6 in.
Height: 11 cm/4.4 in.

Detector
Optical confocal infrared detector: contact-free detection of liquid level, tools used, labware worktables, tip types and quantities
Optical sensor: liquid surface must be 90 +/- 3° to the vertical plane of the optical sensor

Software
Operating software: MotionManager V 1.6 or higher; Firmware: MotionInstrument V 1.6 or higher; Labware 0.5 or higher

Features

       
  • 4 labware positions, plus three virtual spaces    
  • Pipetting range from 1 µL to 1,000 µL   
  • Compatible with micro- and PCR plates    
  • Compatible with plates up to 384 wells   
  • Compatible with tubes from 0.2 mL to 50 mL   
  • Liquid level detection without conductive tips   
  • Optical sensor* checks the loaded deck   
  • Safety hood with monitored front door   
  • Easily exchangeable pipetting tool   
  • Innovative control panel   
  • PC editor software available   
  • Optional PC control version   

Photos

  • epMotion 5070
  • epMotion 5070
epMotion 5070

epMotion 5070

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Picture of EPPENDORF epMotion 5070
You'll see Eppendorf products used in all types of life science research and clinical testing settings—from basic laboratory applications to highly specialized...

More about EPPENDORF

Visit EPPENDORF

Questions and Answers

Recent Question Activity

Be the first to Ask a Question

Reviews

Member Reviews

There are no threads in EPPENDORF epMotion 5070 Reviews at this time.
Add a Review

Buy it Used!

Used EPPENDORF epMotion 5070 Offerings on LabX

Eppendorf epMotion 5075 Liquid Handler

Price: Contact Biodirect

Eppendorf epMotion 5075 Liquid Handler

Price: Contact Biodirect