The Varian CP-3800 GC meets all your analytical requirements with practical solutions for simple and complex applications.
In a standard configuration, the CP-3800 accommodates up to three injectors and three detectors, all operating simultaneously. In addition, the CP-3800 is easily configured to perform on-line analyses for monitoring critical gas and liquid process streams.
The CP-3800’s flexible platform lets you start with a basic configuration and add a wide variety of options in the field. Options include additional channels, gas and liquid sampling valves, and external sampling devices. Future upgrades guarantee that you can meet changing requirements at a moment’s notice.
Unleash the full potential of the CP-3800 GC with the Galaxie Chromatography Data System. Galaxie dramatically improves daily workflow with intuitive, easy-to-use graphical interfaces for instrument control, data acquisition, processing, and standard and custom reporting. From a simple stand-alone GC system, to an automated Simulated Distillation package, the CP-3800 GC with Galaxie provides a powerful solution to all of your GC analytical needs.
The CP-3800 GC from Varian—unlimited possibilities!
CP-3800
Attributes
Programmable
Yes
Temperature Range
4
to
450
°C
Detector
Flame Ionization Detector (FID) • Thermal Conductivity Detector (TCD) • Electron Capture Detector (ECD) • Thermionic Specific Detector (TSD or NPD) • Pulsed Flame Photometric Detector (PFPD)
GC System Type
Modular
Humidity
5% to 95%
(relative)
Number of Detectors
3
Depth
56
cm
Height
53
cm
Width
66
cm
Power Requirements
101V, 120V, 230V
(±10% nominal)
Weight
43
kg
Features
Photos
CP 3800
Manuals and Resources
Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com
Changes have occurred to the Varian, Inc. product lines. On May 14, 2010, Agilent Technologies completed the acquisition of Varian, Inc. (Varian), a supplier...
Hi to all;
During the Running of the GC I got the message display on the screen (Initialization Error “Turn power off then back on” If problem persists, Call Varian Technical Support)
I restart the GC and it is working for 1-2...
Hi !
i am working with varian 3800 gc, on starting the instument its keep off equillibrating and showing not ready light(red). I have try check for leaks in the detector, column nuts and all alone the lines but it still continue.
can...
I always getting a high background for ECD graph, although,
1-the ECD is newly installed.
2-the gas purity is very good 99.9%
3-new humidity filter installed.
4-backed out done overnight for decontamination.
but still the...