Advertisement

Beckman Coulter ProteomeLab™ XL-A/XL-I

Share:

ProteomeLab™ XL-A/XL-I

Beckman Coulter pioneered the field of analytical ultracentrifugation and continues to design and produce powerful, reliable, and durable instrumentation to enable academic and industrial research around the world. 
 
By measuring proteins as interacting elements, ProteomeLab XL-A and XL-I systems accelerate the development of diagnostic markers and therapeutic targets for efficient and reliable protein characterization in solution. 
 
Each ProteomeLab system is designed to put actionable information in your hands quickly and easily. 
 
Native-condition characterization for better lead optimization, better drug candidate evaluation, better method validation....better science. The ProteomeLab XL-A/XL-I in-solution characterization of proteins, oligomers, aggregates, particles, colloids, and small structures delivers accurate results you can rely on time and again. In-solution characterization allows for testing in native conditions, meaning you determine the sample testing environment that best suits your needs. The unique column-free separating technique of the ProteomeLab XL-A/XL-I measures the relative change in the distribution of molecular weights, providing an efficient way to measure heterogeneity, stoichiometry and self-associating systems. And, because the measurements are based on the first principles of thermodynamics and hydrodynamics, no standards or calibrations are required. As a result, you spend less time on setup and more time on discovery.
ProteomeLab™ XL-A/XL-I
Attributes
Centrifuge Type Analytical
Orientation Floor Standing
Depth 26.5 in
Height 47.5 in
Width 37 in
Weight 1025 lbs

Features

Multiple Detection Systems      
The ProteomeLab XL-A is configured with a scanning UV/Vis detection system that provides sensitivity for low-concentration work and selectivity for optimizing detection based on the sample's maximum absorbance. The addition of Rayleigh Interference Optics provides the capability to measure the change in refractive index resulting from changes in sample concentration. This delivers increased accuracy and the ability to examine a greater concentration range with a wider selection of samples. The XL-I can collect data from both detection systems sequentially, to provide the broadest spectrum of data for protein characterization in solution.      
      
Easy Sample Preparation      
For easy sample preparation, inject as little as 15µL to 120µL of sample and reference solutions into opposing positions in the cell assembly, and place the assembly into the system. Up to 28 different sample/reference pairs can be studied in a single run, with each having a different set of solute/solvent conditions (pH, ionic strength, concentration). This provides data for accurate analysis in as little as three hours. Your sample can be retrieved for additional analysis.      
      
Flow-Through Centerpiece Assembly      
A pre-assembled cell features a flow-through centerpiece that saves you time. Sample and reference solutions can be directly injected in the cell and retrieved for additional analysis without assembling or disassembling the cell. A second hole above each channel allows the cell to be cleaned and rinsed (with tubing and syringe) and ready for the next run.

Photos

  • ProteomeLab™ XL-A/XL-I Protein Characterization System

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Picture of Beckman Coulter ProteomeLab™ XL-A/XL-I

Beckman Coulter

Beckman Coulter, Inc. is a leading manufacturer of biomedical testing instrument systems, tests and supplies that simplify and automate laboratory processes....

More about Beckman Coulter

Visit Beckman Coulter

Questions and Answers

Recent Question Activity

Ask a Question

Persistent DIAG 63 Drive error

Dear all I am trying to bring back to life a Beckman Optima XL-I AUC. I am getting DIAG 63 errors that wont clear. After pressing CE it comes back within a second. Due to having measured 13 volt from a 12 v regulator (U3) I was advised to change the...

can't accelerate to 42000 rpm

DIAG:33 :BAD UNKNOW? OVERSPEED DISK CHECK DISK AND REPLACE IF NEEDED