Teledyne Technologies, Inc. Z-2000 Series

Share:

Z-2000 Series

Easier Operation, More Reliable Analyses and Higher Sensitivity. This is the concept of Z-series polarized Zeeman AAS. Three models are available to meet your specific needs.  
High Quality: Excellent Sensitivity using Zeeman Method and Dual Detector.  
Compact: Installation Space is Reduced (Z-2300/2700)  
Useful Design: Slim design with built-in Graphite Furnace Autosampler  
  
New optics and improved graphite furnace power supply circuit enhance sensitivity. Using common hollow cathode lamps, Z-2000 Series spectrophotometer is capable of analyzing As, Se and Sb in tap water and environmental water, which previously have only been measurable by using EDL (high-intensity) lamps in conventional graphite furnace analyses.

Models

Z-2000
Attributes

Edit Model

Graphite Furnace Yes
Lamps 8 Lamps(turret), 2 Lamps simultaneous lighting
Optical System Double-beam method (Polarized Zeeman method)
Zeeman Yes
Wavelength Range 190 to 900 nm Automatic spectral peak setting
Depth 63 cm
Height 70 cm
Width 110 cm
Power Requirements 220/230/240 V, 50/60 Hz
Peak Power 6000 VA
Weight 189 kg
Additional Specifications Analytical method: Flame/Graphite furnace
Measurement mode: Atomic absorption and flame phtometry
Background correction: Polarized Zeeman method

Monochromator
Mount/diffraction grating: Czerny-Turner mount, 1800 Lines/mm, Blazed at 200 nm
Focal length, reciprocal dispersion: 400 mm, 1.3 nm/mm
Slit width: 4 steps( 0.2, 0.4, 1.3, 2.6 nm)

Light source
Lamp position control: Automatic position setting, fine adjustment function

Flame part:
Zeeman-effect magnet: 0.9 Tesla permanent magnet
Burner: Pre-mixed fish-tail type
Ignition method: Pilot flame automatic ignition
Combustion condition setting: Automatic flow rate setting of combustion gas
Safety monitoring function: Optical flame monitoring, flame sensor error detection, fuel/auxiliary gas pressure monitoring, drain liquid level monitoring, cooling water flow monitoring, flash-back shock absorption, safety flame extinguishing at power failure (buffer tank method), N2O select safety mechanism, etc.

Graphite furnace part
Zeeman-effect magnet: 1.0 Tesla permanent magnet
Temperature control: 50 to 2,800, over current protection
Heating current control: Optical temperature control, constant current control
Gas flow rate control:
Sheath gas: Ar gas; 3 L/min.
Carrier gas: Ar gas; 0, 10, 30, 200 mL/min.(4 steps)
Safety monitoring control: Ar gas pressure monitoring,
cooling water flow monitoring, furnace temperature monitoring

Graphite furnace autosampler
Number of sample containers: 60 pcs (1.5 mL container), 96-well micro plate [option]
Modifier container: 5 pcs(25 mL container)
Sample injection volume: 1 to 100µL
Sample injection reproducibility: RSD 1% or less (5 to 100µL)
Sample injection speed: Selectable in 5 steps
Rinse solution discharge: 1 mL
Applicable solvents: Aqueous solution, ethanol, methanol, acetone, MIBK
Carry-over: 10^-5 or less (for standard aqueous solution sample)
Heating injection function: Yes
Number of nozzle washing: 5 times
Sample condensation (in furnace): 1 to 25 times
Sample dilution (in furnace): 1 to 10 times
Z-2300
Attributes

Edit Model

Graphite Furnace No
Lamps 8 Lamps(turret), 2 Lamps simultaneous lighting
Optical System 8 Lamps(turret), 2 Lamps simultaneous lighting (Polarized Zeeman method)
Zeeman Yes
Wavelength Range 190 to 900 nm Automatic spectral peak setting
Depth 63 cm
Height 70 cm
Width 75 cm
Power Requirements 115/220/230/240 V, 50/60 Hz
Peak Power 200 VA
Weight 106 kg
Additional Specifications Analytical method: Flame
Measurement mode: Atomic absorption and flame phtometry
Background correction: Polarized Zeeman method

Monochromator
Mount/diffraction grating: Czerny-Turner mount, 1800 Lines/mm, Blazed at 200 nm
Focal length, reciprocal dispersion: 400 mm, 1.3 nm/mm
Slit width: 4 steps( 0.2, 0.4, 1.3, 2.6 nm)

Light source
Lamp position control: Automatic position setting, fine adjustment function

Flame part:
Zeeman-effect magnet: 0.9 Tesla permanent magnet
Burner: Pre-mixed fish-tail type
Ignition method: Pilot flame automatic ignition
Combustion condition setting: Automatic flow rate setting of combustion gas
Safety monitoring function: Optical flame monitoring, flame sensor error detection, fuel/auxiliary gas pressure monitoring, drain liquid level monitoring, cooling water flow monitoring, flash-back shock absorption, safety flame extinguishing at power failure (buffer tank method), N2O select safety mechanism, etc.
Z-2700
Attributes

Edit Model

Graphite Furnace Yes
Lamps 8 Lamps(turret), 2 Lamps simultaneous lighting
Optical System Double-beam method (Polarized Zeeman method)
Zeeman Yes
Wavelength Range 190 to 900 nm Automatic spectral peak setting
Depth 63 cm
Height 70 cm
Width 75 cm
Power Requirements 220/230/240 V, 50/60 Hz
Peak Power 6000 VA
Weight 139 kg
Additional Specifications Analytical method: Graphite furnace
Measurement mode: Atomic absorption spectrometry
Background correction: Polarized Zeeman method

Monochromator
Mount/diffraction grating: Czerny-Turner mount, 1800 Lines/mm, Blazed at 200 nm
Focal length, reciprocal dispersion: 400 mm, 1.3 nm/mm
Slit width: 4 steps( 0.2, 0.4, 1.3, 2.6 nm)

Light source
Lamp position control: Automatic position setting, fine adjustment function

Graphite furnace part
Zeeman-effect magnet: 1.0 Tesla permanent magnet
Temperature control: 50 to 2,800, over current protection
Heating current control: Optical temperature control, constant current control
Gas flow rate control:
Sheath gas: Ar gas; 3 L/min.
Carrier gas: Ar gas; 0, 10, 30, 200 mL/min.(4 steps)
Safety monitoring control: Ar gas pressure monitoring,
cooling water flow monitoring, furnace temperature monitoring

Graphite furnace autosampler
Number of sample containers: 60 pcs (1.5 mL container), 96-well micro plate [option]
Modifier container: 5 pcs(25 mL container)
Sample injection volume: 1 to 100µL
Sample injection reproducibility: RSD 1% or less (5 to 100µL)
Sample injection speed: Selectable in 5 steps
Rinse solution discharge: 1 mL
Applicable solvents: Aqueous solution, ethanol, methanol, acetone, MIBK
Carry-over: 10^-5 or less (for standard aqueous solution sample)
Heating injection function: Yes
Number of nozzle washing: 5 times
Sample condensation (in furnace): 1 to 25 times
Sample dilution (in furnace): 1 to 10 times

Features

Model Z-2000  
TANDEM TYPE ATOMIC ABSORPTION SPECTROPHOTOMETER  
      
  • The polarized Zeeman method featuring low noise and high stability is adopted for both flame and graphite furnace methods.  
  • Highly accurate analysis is achievable with no need for moving sample compartment or adjusting optics.  
  
Model Z-2300  
FLAME ATOMIC ABSORPTION SPECTROPHOTOMETER  
      
  • The polarized Zeeman method featuring low noise, high stability and high throughput is adopted for the flame method.  
  • Easy operation is supported by Analysis Assist, Real-time QC and Easy Start functions.  
  
Model Z-2700  
GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROPHOTOMETER  
      
  • Highly accurate background correction is possible by Direct Current (DC) polarized Zeeman method.  
  • Integrated design with autosampler and dustproof cover.  

Photos

  • Z-2000 Series
  • Z-2300
  • Z-2700
Z-2000 Series

Z-2000 Series

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Questions and Answers

Recent Question Activity

Ask a Question

Syrup dosage form for metal contamination

Is there a method for determining metal and other impurities in pharma syrup dosage formats using Hitachi Z2000 AAS? 

AAS Fuel pressure

Hi..Need help..Why flame for Hg analysis cant ignite?My AAS hitachi z2000.. And the command appears is select fuel pressure lower?Thank you

Enquiry Ref. No. 1402

Ref. KIPL/10-11/1402 March 28, 2011 Dear Sir, Re :- Our Requirement as under. ======================= Kindly quote for the following. Requirement :- Spares of Atomic Absorption Spectrophotometer Model : Z-5000 series Make ...

There are 3 Threads

Reviews

Member Reviews

There are no threads in Teledyne Technologies, Inc. Z-2000 Series Reviews at this time.
Add a Review

Advertisement