Sievers 500 RLe

The Sievers 500 RLe On-Line TOC Analyzer represents the latest advancement in the science of ultra low-level TOC measurement in microelectronic applications. The 500 RLe replaces the Sievers Model PPT as the industry’s only on-line, reagentless TOC analyzer capable of accurately detecting problematic compounds such as urea, trimethylamine, organic acids and bases.  
  
The 500 RLe uses GE Analytical Instrument's membrane conductometric technology, delivering ultra low-level accuracy and reliability by eliminating false positive and false negative readings associated with other simplified TOC technologies.
Sievers 500 RLe
Attributes
Measurement Range .03 to 2500 ppb
NDIR No
On-Line Monitoring Yes
Portable No
Depth 10.8 in
Height 16.5 in
Width 19 in
Power Requirements 100–240 ± 10% VAC, 50/60 Hz
Peak Power 50 W
Weight 37.2 lbs
Additional Specifications Total Organic Carbon  
Measurement Range: 0.03 to 2500 ppb  
Accuracy: ± 0.1 ppb or ±5% of measurement, whichever is greater  
Precision: < 1% RSD or 0.03 ppb as C, whichever is greater  
pH Range: 5.5 to 8.0 in order to meet accuracy specification  
Maximum Sample Conductivity: 25 µS/cm at neutral pH  
Analysis Modes: On-line, on-line averaged, on-line timed  
Analysis Time: Continuous mode: 6 minutes  
Average and timed modes: 0.5, 1, 4, 8, or 24 hours  
External Flow Rate: Minimum 50 mL/min  
Sample Temperature: 1–95 °C (34–203 °F)  
Sample Pressure: Up to 100 psig  
Interferences: Insensitive to organic heteroatoms  
Calibration Stability: Typically 12 months  
Display Readout: 3 significant digits  
  
Instrument  
Normal Operating Environment: Intended for indoor use only  
Ambient Temperature: 10–40°C (50–104°F)  
Maximum Relative Humidity: Up to 95%, noncondensing  
Maximum Altitude: 2,300 m (7,546 ft)  
Inputs: One isolated binary input  
Outputs: Three isolated 20mA outputs, one Serial RS-232 output, one USB port, one parallel printer port, and four alarm outputs  
Installation/Overvoltage: Category II (protects against transients present in Category II power)  
Safety Certifications: ETL, CE  
Pollution Degree: 2 (normally only non-conductive pollution)  
Display: Backlit Quarter-VGA touchscreen display  
IP Rating: Environmental Enclosure: IP-45  
  
Consumables  
UV Lamp: 6 months  
Pump Tubing: (with pump heads) 12 months  
DI Water Cartridge: Typically 24 months (depends on water quality)  
Inline Filter: Replace as needed (depends on water quality)  
DI Water Level Refill: As needed (check when replacing other items)

Features

Economical Designs  
The 500 RLe comes in two models to meet your needs:  
      
  • The 500 RLe with Standard iOS (Integrated On-Line Sampling System) utilizes the familiar Sievers sample inlet device, allowing for on-site calibration, running of standards and grab samples.  
  • The 500 RLe Base Model utilizes a simplified sample inlet block, facilitating continuous on-line operation. On-site calibration may be performed using an optional iOS accessory. The 500 RLe Base Model is cost-competitive with even the simplest TOC sensors while still providing superior analytical performance and optional on-site calibration.  
  
Master TOC Calibration  
The 500 RLe has a manual TOC offset adjustment, so any 500 RLe can be calibrated to a reference TOC analyzer.   
  
Higher Conductivity Limits  
The 500 RLe incorporates design elements from the Sievers 800 and 900 Series that enable reagentless TOC measurement in waters up to 25 ΜS/cm. Equally as important, this design enhancement means that fluctuations in UPW system conductivity or plant transients do not affect analytical performance.  
  
Sensitivity, Accuracy and Stability  
With microelectronic TOC limits being driven ever lower, it is critical that TOC analyzers operate accurately and reliably at sub-ppb levels. The 500 RLe achieves the lowest detection limit of any TOC analyzer on the market — 0.03 ppb — and provides the confidence that all organics are being fully recovered regardless of chemical composition. The combination of analytical robustness and stable sub-ppb performance provides confidence that critical UPW processes are protected and that even the most subtle trends can be closely monitored.

Photos

Sievers 500 RLe

Sievers 500 RLe

Manuals and Resources

Note: We appreciate the support of individuals and companies making their documents and resources available to our community. If you find a document or resource that does not belong please let us know by emailing info@labwrench.com

Instrument Documents

Picture of GE Analytical Instruments Sievers 500 RLe
Part of GE Power & Water, GE Water & Process Technologies GE Analytical Instruments designs and manufactures state-of-the-art instruments...

More about GE Analytical Instruments

Visit GE Analytical Instruments

Questions and Answers

Recent Question Activity

Be the first to Ask a Question

Reviews

Member Reviews

There are no threads in GE Analytical Instruments Sievers 500 RLe Reviews at this time.
Add a Review