A Case for Laboratory Automation

Problem: While laboratory instruments have become faster and more automated to increase productivity, sample preparation has continued to remain a bottleneck and source of variability for most labs. The complexity and variety of samples that typically pass through labs makes this area one of the most difficult to automate. The use of Automated sample Preparation equipment can impact:

Productivity: Automated sample preparation can save ½ hour or more of analyst time per shift which translates to ≈ 550 hours labor savings per year (0.5 hrs per shift x 3 shifts per day x 365 days per year).

Quality:
Precision of automated sample preparation exceeds the precision achieved by multiple analysts across shifts which improves the quality and reliability of results. The repetitive nature of automation is more consistent than manual preparation which reduces the risk of analyst errors. This in turn lowers laboratory costs by reducing rework and lowers the risk of price concessions for offspec product due to lab error for the client.

Read more about the benefits of Automated Sample Preparation equipment here.

 Product of Interest

Recirculating Chillers

JULABO recirculating chillers can handle virtually any cooling requirements in laboratories or industrial environments. Their efficiency makes them an environmentally-friendly and economical alternative to cooling with tap water.

The FL series offers a new generation of chillers for routine cooling applications from 0.3 kW to 20 kW and up to 60 l/min flow. The temperature stability of the PID control is ±0.5°C. All units can easily be cleaned and come with a splash water proof keypad with LED temperature indication.  
 
To read more about JULABO Recirculating Chillers visit their website.


Design Your Eclipse Steel Casework Online

The Eclipse™ series of casework provide the building blocks to easily and systematically furnish any modern lab. Now configure your casework online and obtain your quote via email. The Eclipse Online Configurator features drag & drop simplicity. Choose for dozens of drawer and cabinet configurations in both counter- or desk-height models. Fast and easy. Eclipse™ series brings versatility, ease of future expansion and reconfiguration, storage, mobility, strength and stability, with full accessibility to mechanical, plumbing and electrical components.

Whether you are building a new laboratory, renovating or upgrading an existing lab, the Eclipse™ Series of laboratory furnishing will fulfill your needs.   Learn more at the IAC Industries website.

 Help your Colleagues

Plenty of discussions are happening on LabWrench all the time. We have many questions come in daily from users that are seeking advice from fellow users and lab professionals on LabWrench. Can you help any of these users find the answers they are looking for?

Shimadzu SSI GC-2014 - ARA
My research is about the capability of associative N2-fixing bacteria to fix nitrogen and it will be observed by acetylene reduction assay. My laboratory has 3 column (Restex serial no. 935315, 937846, 939370).
1. Of the three column, which is suitable for the assay?
2. How to set up the GC for ARA, especially temperature (column, detector), flow rate (carrier gas), etc.  Thank you. Respond to this member.

O'ryan Fiberoptic light source (Microscopy Questions and Answers forum)
Need specs for the transformer in an O'Ryan LS-150 fiberoptic light source. The transformer in this unit has burned out - there are no identification markings on the transformer. Advise this member.

Eppendorf 5417c braking circuit malfunction
Hi guys, I have two 5417C benchtop c'fuges that are burning-up their brake resistors just sitting ON at idle.  I have replaced the main filter caps & several small transistors and such on the main PCB, but the symptom persists.  
Has anyone dealt with this issue?  The original resistors were blown-up and a couple of PCB traces were cooked and needed bypassing as well.  I'm at my limits without schematics, and Eppendorf says there are none because they don't do component-level repairs.  $2100 for a new board seems a bit steep to me. Provide feedback.

View all Questions and Discussions on LabWrench.

 Have a Question ??

 Company News Hot Off The Press

Aura® ductless chemical fume hoods.
Aura® ductless fume hoods provide state of the art construction and safety features.  Each Aura® ductless fume hood has advanced safety monitoring and controls.   EverSafe II™ microprocessor safety controller monitors and adjusts fume hood face velocity to the user preset value. Read more.


Starter Kit for SPE Sample Preparation.
The new starter kit offers all the advantages of SPE sample preparation in a convenient microplate format, capable of rapidly processing 96 samples in one run, repeatedly and precisely. All that is required for full operation is a suitable laboratory vacuum connection or pump.  The new starter kit offers all the advantages of SPE sample preparation in a convenient microplate format, capable of rapidly processing 96 samples in one run, repeatedly and precisely.  Read more.

Easy Concentration of Large Sample Volumes
SampleGenie 3 technology used in conjunction with the Genevac ROCKET Evaporator enables large sample volumes to be dried directly into vials, eliminating a number of time consuming sample handling steps and the attendant risk of errors. The new third generation SampleGenie enhances the exceptional capabilities of this unique sample concentration methodology through improved ease of use, enhanced evaporation performance and reduced operational costs. Read more.

View all news articles on LabWrench

 Sponsor of the Week

Thank you to Horizon Technology Inc for sponsoring the Sample Preparation category on LabWrench.

Horizon Technology is a leading manufacturer of automated sample preparation systems for the analysis of organic compounds in aqueous samples and Oil & Grease testing.

Labs who test for Semi-Volatile Organics, Oil & Grease, DROs, TPH, Pesticides, PAH's, Explosives, Pharmaceutical By-Products and Personal Care Products have found their, automated sample preparation systems for solid phase extraction, evaporation and drying increase productivity, improve the accuracy of their results and lower operating costs.

They are the experts in instruments, applications, consumables and technical support for solid phase extraction, solvent drying and concentration.   Visit their website to learn more about Horizon Technology Inc.

 Questions from the Vault

We have so many questions filling our forums that sometimes questions can be missed and go without answers. Can you help us provide answers for these users with unanswered questions?

Shandon Cytospin3 error code "="
Shandon Cytospin3.  When the cytospin reaches set rpm's  it will stop spinning.  An error code of "=" appears in the program display.  I called Thermo Shandon but the unit has been out of support since 2003.  Any help would be appreciated. Provide some feedback.

Error [15] Hach DR 2800™ Spectrophotometer?
DR 2800: on start up the error [15] appear.  Why??? How repair?.  Help this member.

MILLI-Q RO 4
Millipore has made the 12'acetate ro acetate filter obsolete - CDRCM25S1 Anyone know of an equivalent alternative that would be compatible? Help this member.

View all Questions and Discussions on LabWrench

 Upcoming FREE Webinar
When and How Should You Automate and Streamline Your Cell Culture?

Thursday October 17, 2013
12:00 p.m. - 1:30 p.m. Eastern Time

Register Now!

 Sponsored by:

 Contact Us

For editorial and sales inquiries for this newsletter email - info@labwrench.com or call 705-528-6888 x294

  | 


 

Follow LabWrench on Twitter

Like LabWrench on Facebook

Connect with LabWrench on LinkedIn


Refer a Colleague
to LabWrench