New Compact Microspectrometer Design Achieves High Resolution & Wide Bandwidth

A new microspectrometer architecture that uses compact disc-shaped resonators could address the challenges of integrated lab-on-chip sensing systems that now require a large off-chip spectrometer to achieve high resolution.

Spectrometers have conventionally been expensive and bulky bench-top instruments used to detect and identify the molecules inside a sample by shining light on it and measuring different wavelengths of the emitted or absorbed light. Previous efforts toward miniaturizing spectrometers have reduced their size and cost, but these reductions have typically resulted in lower-resolution instruments.

“For spectrometers, it is better to be small and cheap than big and bulky -- provided that the optical performance targets are met,” said Ali Adibi, a professor in the School of Electrical and Computer Engineering at the Georgia Institute of Technology. “We were able to achieve high resolution and wide bandwidth with a compact single-mode on-chip spectrometer through the use of an array of microdonut resonators, each with an outer radius of two microns.”

Read more about developments in Microspectrometer design by clicking here.

DURAN® GLS 80 laboratory bottle, wide mouth with GLS 80 thread

With an 80 mm wide outer diameter bottle neck, this bottle is ideal for filling, pouring, shipping and sampling granulated material, powders and viscous substances.  Complete with blue quick release closure (PP, integral lip seal) and pouring ring (PP) for drip-free pouring, this bottle has an easy-to-read scale and large labelling field for easy marking.

Visit the SCHOTT website to view all of their glass products.

 Refurbished Lab Equipment

Pace Analytical Services, Inc. is a privately held, industry-leading sampling and analytical testing firm. Pace provides analytical lab solutions for testing, staffing and equipment, with a wide scope of services.

  • Dissolution
  • GC/MS
  • Gas Chromatograph
  • General Lab Equipment
  • Inorganic (ICP, ICP-MS, Accessories)
  • LC/MS

Visit Pace Analytical to see a full list of the refurbished Lab Equipment they have for sale.

Plenty of discussions are happening on LabWrench all the time. We have many questions come in daily from users that are seeking advice from fellow users and lab professionals on LabWrench. Can you help any of these users find the answers they are looking for?

How do I set up kinetic mode in Analytik Jena SPECORD® Plus 210 plus
I would like to determine urea in serum sample using urease-GLDH enzymatic UV method (DiaSys test kit). How do I set up the protocol for the test? After we mixed the sample and reagent, then OD1 should be measured; then again in 50 second OD2 will be measured (2 point kinetic measure). I need the value of OD1-OD2 (the difference) then multiplied by the fixed factor. This might be easy to measure using the protocol that is already available in the SPECORD Plus 210, but I would like to know how to set up protocol for a kinetic test. Help this member.

Cobalt and Iron interference in Spectroscopy
I want to know if there is an analytical method to quantitatively separate about 100 microgram per litre of Cobalt from about 50miligram per litre of Iron in the same liquid sample before analysis in an XRF spectrometry. Without separation, the K (beta) lines of Fe overlap the K (alpha) lines of Co hence the recovery of Co is only about 60%. I am interested in the Cobalt not the Iron. Help this member.

Atomic Absorption Spectroscopy - Thermo Fischer Scientific iCE 3000
We have used above mentioned instrument for metal Detection. We are facing problem while using Nitrous oxide and Acetylene gas combination. In Chromium and Silicon was tested we are using these gases. In this case we are not getting Absorbance while using the standard solution. We are checking the standard solution in other instruments it is ok - other parts like Nebulizer and Gas inlet areas are good. But still we are not getting absorbance. We consulted with our service person, and they said the Acetylene and Nitrous oxide combination the flame should be Red cone formation in without sample. But we are only getting Blue with mixed yellow color in without sample. Only red cone formation while the sample was injected. Sample also not getting absorbance. We are not getting correct solution. Help this member.

View all Questions and Discussions on LabWrench.

Thank you CRAIC Technologies for sponsoring the Microspectrometer category on LabWrench.

CRAIC Technologies develops optical microanalysis solutions for many fields and industries.  These include instruments that offer the ability to measure UV-visible-NIR transmission, reflectance, fluorescence, polarization and Raman spectra of microscopic sample areas.  These same instruments are also able to capture microscopic images throughout the ultraviolet, visible and near infrared regions.  Additional features also include microspot thin film thickness measurements, colorimetry, NIST traceable standards, automation and more.  By building modular systems, all or some of these capabilities can be offered on the same instrument.  

Visit the CRAIC Technologies website  to view their full line of products.

New Asia Tube Cooler from Syrris enables extra low temperature flow reactions

Syrris, a world leader in flow chemistry product innovation, is pleased to announce the launch of the Asia Tube Cooler, the latest addition to the Company’s range of advanced flow chemistry products.  Read more.

Compact Solution for Parallel Blending & Formulation Experiments

Asynt has developed a new adaption of its Vortex overhead stirrer, called the Vortex Blend, specifically to cater for the requirement of scientists who need to test new formulations and blends in parallel.  Read More.

Rigaku Launch The Smart Sample Loading System for Their Primus WDXRF Spectrometers
Rigaku Corporation is pleased to announce the introduction of the new Smart Sample Loading System for use on its ZSX Primus wavelength dispersive X-ray fluorescence (WDXRF) spectrometers.  The Smart Sample Loading System has been developed in response to market needs for higher unattended throughput and improved accuracy of data transmission to reduce or eliminate sample tracking errors. Read more.

 Click here to view all news articles on LabWrench.

Handling Gas: Cylinder vs. Gas Generator

Thur. April 17, 2014
12:00 - 1:30 PM EDT

 Register Now!

Sponsored by

We have so many questions filling our forums that sometimes questions can be missed and go without answers. Can you help us provide answers for these users with unanswered questions?

Jasco 530 Spectrophotometer error
I have a Jasco 530 Spectrophotometer and the screen displays an error after the completion of the initialization process (error detected in next part, Deuterium lamp).  I changed the lamp with a new one but the problem is still not solved. Advise this member.

Agilent Technologies 5975C Series GC/MSD
In GC-MSD 5975C, C stands for what? And what is a triple axis detector?  Share your knowledge.

Is a diffuse reflectance accessory available for the Varian Cary Bio50?
I would like one that is similar to the Perkin Elmer Lamda 950 UV-Vis-NIR Spectrophotometer with a 150 mm integrating sphere (Lamda 950, Perkin Elmer).  I need to take measurements on membranes and solar cell plates in the range 200-800nm. Provide an answer.

Click here to view all Questions and Discussions on LabWrench.