Wilson Hardness - Tukon 1002 Series
Manufactured by Wilson Hardness
Offers a versatile and user friendly solution for a wide range of micro-hardness scale testing.
The Tukon 1102 & 1202 Knoop/ Vickers Series Hardness Testers offer a versatile and user friendly solution for a wide range of micro-hardness scale testing. For single scale micro-hardness testing, the Tukon 1102 Tester is equipped with a three position turret which includes one indenter position as well as a 10x and 50x objective. For more demanding applications, the Tukon 1202 Tester is equipped with a six position turret, including two indenter positions as well as a 5x, 10x and 50x long working distance objectives. Both units include USB output, eight dial selectable test forces and an innovative touch panel user interface for rapid test method handling and data collection.
Active Questions & AnswersAsk a Question
There are no current Discussions
Hardness Testers Service ProvidersView All (2)
Documents & Manuals
There are no Documents or Manuals available.
Features
There are no Features available.
General Specifications
There are no General Specifications available.
Series Modals
Wilson Hardness - Tukon 1102
[+] View Model SpecificationsDepth | 520 mm |
Height | 520 mm |
Width | 230 mm |
Power Requirements | 110 - 220V AC, 60/50Hz |
Weight | 40 kg |
Additional Model Specifications | Hardness Scales: Knoop & Vickers Test Load (gf): 10, 25, 50, 100, 200, 300, 500, 1000 (2000) Test Load Selection: Dial with electronic feedback Standards Compliant: EN-ISO 6507, ASTM E384 & E92, and JIS Test Cycle: Automatic (loading/ dwell/ unloading) Dwell Time: 5 - 99 seconds Automatic Turret: 3 position: 1 indenter, max. 2 objectives Turret Speed: 120° per second Statistics: Number, Mean, Standard Deviation, Minimum, Maximum and Range Eyepiece Magnification: 10x Digital Encoder Resolution: 0.1Μm Total Magnification: 100x, 500x Standard Objectives: 10x, 50x (SWD) Optional Objectives: 5x, 10x, 20x, 50x, 100x (LWD) Measuring Range: 200Μm at 10x Optical Path: Dual, eyepiece or optional camera Camera (Optional): 1.3 MP integrated in pedestal Specimen Illumination: LED Display: 5.7 in (144.8 mm) SMART-UI touch screen display with tab interface Diagonal Length: 4-digit (d1, d2) Data Output: USB memory stick (csv format), RS232 Conversions: Brinell, Vickers, Rockwell and Tensile Strength according to ASTM E140, ISO 18625 and GB Vertical testing capacity: without anvil 130 mm (4.7 in) / with XY-stage 95 mm (3.7 in) Depth from Center line: 130 mm (5.1 in) XY-Stage (Optional): Size: 100 × 100 mm (3.9 × 3.9 in) Travel Range: 25 × 25 mm (1.0 × 1.0 in) Operating Temperature Range: 10° to 38° C (50° to 100° F) Humidity: 10% - 90% non-condensing |
Wilson Hardness - Tukon 1202
[+] View Model SpecificationsDepth | 520 mm |
Height | 520 mm |
Width | 230 mm |
Power Requirements | 110 - 220V AC, 60/50Hz |
Weight | 40 kg |
Additional Model Specifications | Hardness Scales: Knoop & Vickers Test Load (gf): 10, 25, 50, 100, 200, 300, 500, 1000 (2000) Test Load Selection: Dial with electronic feedback Standards Compliant: EN-ISO 6507, ASTM E384 & E92, and JIS Test Cycle: Automatic (loading/ dwell/ unloading) Dwell Time: 5 - 99 seconds Automatic Turret: 6 position: 2 indenter, max. 4 objectives Turret Speed: 120° per second Statistics: Number, Mean, Standard Deviation, Minimum, Maximum and Range Eyepiece Magnification: 10x Digital Encoder Resolution: 0.1Μm Total Magnification: 50x, 100x, 500x Standard Objectives: 5x, 10x, 50x (LWD) Optional Objectives: 5x, 10x, 20x, 50x, 100x (LWD) Measuring Range: 200Μm at 10x Optical Path: Dual, eyepiece or optional camera Camera (Optional): 1.3 MP integrated in pedestal Specimen Illumination: LED Display: 5.7 in (144.8 mm) SMART-UI touch screen display with tab interface Diagonal Length: 4-digit (d1, d2) Data Output: USB memory stick (csv format), RS232 Conversions: Brinell, Vickers, Rockwell and Tensile Strength according to ASTM E140, ISO 18625 and GB Vertical testing capacity: without anvil 130 mm (4.7 in) / with XY-stage 95 mm (3.7 in) Depth from Center line: 130 mm (5.1 in) XY-Stage (Optional): Size: 100 × 100 mm (3.9 × 3.9 in) Travel Range: 25 × 25 mm (1.0 × 1.0 in) Operating Temperature Range: 10° to 38° C (50° to 100° F) Humidity: 10% - 90% non-condensing |