Thermo Scientific - MAT 253

Manufactured by  Thermo Scientific
Follow this Equipment

Stable Isotope Ratio Mass Spectrometer

Thermo Scientific* MAT 253 Stable Isotope Ratio Mass Spectrometer System delivers the highest sensitivity and precision for the determination of isotope ratios.   
   
Provides a flexible and open platform for the connection of inlet systems and preparation devices.
Active Questions & AnswersAsk a Question

Recent Questions & Answers

avatar placemark

Asked byKPietro

avatar placemark

Asked byShail

avatar placemark

Asked bybio-leaders

Other MS Service ProvidersView All (41)

Request Support
Features of MAT 253
  • Computer switchable amplifier gain   
  • Hydrogen continuous flow capability   
  • Highest sensitivity and linearity   
  • "Fast bellows" system   
  • Computer-controlled ion source potentials and parameters   
  • Up to eight simultaneous acquisition channels   
  • "Plug and measure" peripheral recognition   
  • Small footprint and proven robustness   
  • Easy set up, tuning and fully automatic operation   
  • Ion source with variable conductivity   
  • All-metal sealed ion source and analyzer   
  • Monolithic all-metal valves with gold gaskets   
  • 100% analyzer transmission   
  • Mass resolution 200 (C,N,O,S)   
  • Only system for e.g. SF6, SiF4, Xe   
  • Isodat Script Language (ISL) provides access to all processes and allows modification of supplied scripts as well as development of entirely new measurement and evaluation protocols   

The Thermo Scientific MAT 253 stable isotope ratio mass spectrometer system delivers the highest precision for the determination of H/D, 13C/12C, 15N/14N, 18O/16O, 34S/32S (from SO2 and SF6), 28Si/29Si as well as Ar, Kr and Xe isotope ratios.

General Specifications

There are no General Specifications available.

Additional Specifications

Mass Range:    
1 to 150 dalton at 10kV   
Resolution:    
CNOS: m/delta m = 200 (10% valley), HD: m/delta m = 25 (10% valley)   
Peak Top Flatness:    
Better than 2 x 10e-4   
Sensitivity (absolute):    
600 molecules CO2 per mass 44 ion at the collector (600 molecules/ion)   
Abundance Sensitivity:    
The contribution of the mass 44 intensity to the intensity of mass 45 is less than 2 x 10e-6   
Sample Consumption:    
0.031nmol/s for 1.5V signal (5nA) at mass 44 in the Dual Inlet mode 0.047nmol/s for 1.5V signal (5nA) at mass 44 in the Continuous Flow Mode   
Ion Source Linearity:    
0.02%/nA ion current (mass 44) at a sensitivity corresponding to 900 molecules/ion   
H3+ Factor:    
Smaller than 10ppm/nA