Beckman Coulter - Allegra X-30 Series

Manufactured by  Beckman Coulter
Follow this Equipment

The Compact General Purpose Centrifuge

The Allegra X-30 Series Benchtop Centrifuges were designed with your needs in mind providing you with excellent performance and easy operation in a compact design that saves you valuable time and laboratory space.

  • Highest speed and g-force in its class
  • Simple and quick run setup
  • Flexible with extensive rotor library for multiple applications
  • Compact Design – Only 18" wide (46cm)
  • BioCertified* swinging-bucket and fixed-angle rotors
Active Questions & AnswersAsk a Question

Recent Questions & Answers

avatar placemark

Asked bywanda.seda5462

avatar placemark

Asked byBlueWolfen

avatar placemark

Asked bysyed8898

Centrifuge Service ProvidersView All (22)

Request Support
Features of Allegra X-30 Series

Three different ways to spin 1.5mL and PCR tubes

  • BioCertified* 24-place fixed-angle rotor – 29,756 x g
  • 30-place fixed-angle rotor – 28,672 x g
  • 24-place swinging-bucket rotor – 16,244 x g for flat pelleting

Spin 500 µL o 1.6Lwith the SX4400 Swinging Bucket Rotor

  • 4 x 400 mL maximum capacity

  • 4,700 rpm – 4,255 x g maximum capacity

  • 20 different adapters

  • Spins

    • 400mL bottles
    • 250 mL Bottles
    • 100 mL, 94 mL, 85 mL Bottles
    • 50 mL conical and round-bottom tubes
    • 15 mL conical and round-bottom tubes
    • 30 mL, 25 mL, 10 mL, 5mL tubes
    • 1.5 mL and 500 µL PCR tubes

S6096 Microplate Rotor

  • 2x3 microplates or 2x1 deep-well plates maximum capacity
  • Ambient 4700 rpm / 2721 x g maximum
  • Refrigerated 4700 rpm / 2721 x g maximum

F2402H Fixed Angle Rotor

  • BioCertified* 24 x 1.5 / 2ml micro tubes maximum capacity
  • Ambient 16000 rpm / 23511 x g maximum
  • Refrigerated 18000 rpm / 29756 x g maximum
  • Spins 1.5 mL and 500 µL PCR tubes
General Specifications

There are no General Specifications available.

Additional Specifications

Approximate Acceleration Time: 10 settings     
Approximate Deceleration Time: 10 settings     
Drive Type: Asynchronous three-phase direct-drive     
g Force: 23,511     
Maximum Heat Dissipation into Room under Steady-State Conditions: 0.48 kW     
Noise Level 0.91 meters (3 feet) in Front of Centrifuge: Less than 68 dBa     
Rotor ID: Yes     
Set Speed: Yes     
Set Temperature: No     
Set Time: Yes     
Speed Control: Yes

Series Modals

Beckman Coulter - Allegra X-30

[+] View Model Specifications

Beckman Coulter - Allegra X-30R

[+] View Model Specifications
NewsView All Articles

Looking for

Beckman Coulter - Allegra X-30 Series?

Shop on LabX.com