PerkinElmer - Clarus SQ 8
Sensitivity. Stability. Versatility.
The revolutionary Clarus SQ 8 GC/MS is engineered around the industry’s most sensitive, yet durable Clarifi™ detector and a unique SMARTsource™ (Simplified Maintenance And Removal Technology) that is easy to remove and clean – without tools. The Clarifi detector provides you with the flexibility to choose your ideal level of sensitivity and dynamic range, eliminates background noise and maximizes analyte signals. SMARTsource enables you to virtually reconfigure between EI and CI – simply and quickly.
Clarus SQ 8 GC/MS features the fastest conventional GC oven available – heating up or cooling down more rapidly than other competitive ovens. Plus, the system is driven by our sample-centric TurboMass™ software for ease-of-use from data collection to evaluation and reporting. Combine the Clarus SQ 8 GC/MS with our market-leading TurboMatrix™ sample handling, user-friendly software and world-class service for an integrated, complete analytical solution from a single source.
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Asked byfmiard
GC-Single Quad/MSD Service ProvidersView All (1)
Documents & ManualsView All Documents
Features of Clarus SQ 8
- World’s most sensitive detector delivers exceptional sensitivity
- Easiest source to access and maintain (EI and CI)
- Universal Programmable Split/Splitless (PSS) Injector
- Headspace and Thermal Desorption Sample Introduction Systems
- Marathon™ Filament delivers long life even under the most difficult chromatography conditions
- TurboMass GC/MS software delivers easy environmental compliance
- Fastest heat-up and cool-down oven in conventional GC
- Choose from: Clarus SQ 8 S, Clarus SQ 8 T, Clarus SQ 8 C
General Specifications
| Depth | 32 in Clarus SQ 8 T GC/MS (with Autosampler) |
| Detector | ClarifiTM detector—long-life high sensitivity electron multiplier detector |
| Height | 33 in Clarus SQ 8 T GC/MS (with Autosampler) |
| Temperature Range | 10 to 30 °C |
| Mass Range | 1 to 1200 |
| Width | 39 in Clarus SQ 8 T GC/MS (with Autosampler) |
| Power Requirements | 120 VAC +– 10% @ 50/60 Hz +– 1% 1,000 VA, 230 VAC +– 10% @ 50/60 Hz +– 1% 1,000 VA |
Additional Specifications
[u]Hardware[/u]
Ion Source: PerkinElmer SMARTsourceTM—Simplified Maintenance and Removal Technology (EI and CI compatible)
Filament: MarathonTM—designed for long life
Analyzer: Quadrupole with pre-filter
Mass Stability: +–0.1 m/z over 48 hours
EI Voltage: 10 – 100 eV
Vacuum Pumps: T and C models: 255 L/sec (nitrogen) air-cooled turbomolecular pump (230 L/sec helium pumping capacity)
S model: 75 L/sec (nitrogen) air-cooled turbomolecular pump (59 L/sec helium pumping capacity)
Vacuum Gauge: Single wide-range gauge (standard on all models)
Pump-down Time: 255 L/sec turbomolecular pump: <3 minutes for air/water check, <90 minutes for quantitative stability
Temperature Settings: SMARTsource: Settable 50 °C – 350 °C, GC transfer line: Settable 50 °C – 350 °C
Carrier Gas Flow Rate: 255 L/sec turbomolecular pumping systems: 5 ml/min, 75 L/sec turbomolecular pumping systems: 1.5 ml/min
Mass Calibrant: PFTBA (FC-43) gas, triazine (high mass applications), user selectable
MS Isolation: SwaferTM Micro-Channel Flow Technology
Field Upgrades: Positive/negative chemical ionization (255 L/sec), standard to large turbomolecular pump (75 L/sec to 255 L/sec), water cooling (all models)
[u]Performance[/u]
MS Data Collection: Full Scan, Selected Ion Monitoring (SIM), Simultaneous Full-Scan Selected Ion Monitoring (SIFI)
Scan Rate: Fully variable up to 12,500 amu/sec
Acquisition Rate: 100 points/sec (SIM)
Functions/Run: 32 functions or 32 ions per function
Linear Dynamic Range: 106 dependant on acquisition rate
[u]Data system[/u]
Software: TurboMassTM 6.0 designed for Windows 7 professional operating system
Methods: Electronically transferable between all TurboMass and Clarus GC/MS systems
GC Acquisition: Full control and data processing of a single GC/MS with up to 2 GC detectors
MS Tuning: UltraTuneTM: Standard Tune environmental tuning optimized for EPA methods; Custom Tune user definable optimization
Reporting: Included in all models with specialized reports for: Environmental and forensic applications.
Optional Software:
MS Libraries: NIST Mass Spectral Library, including AMDIS Deconvolution, Wiley Mass Spectral Library Maurer/Pfleger/Weber Library of Drugs,
Pollutants, Pesticides, and Metabolites
Advanced Processing: Ion Signature Deconvolution software
[u]Physical[/u]
Power: 120 VAC +– 10% @ 50/60 Hz +– 1% 1,000 VA, 230 VAC +– 10% @ 50/60 Hz +– 1% 1,000 VA
Temperature: 10 °C – 30 °C (10 °C – 35 °C with water cooling option)
Relative Humidity: 20 – 80 % non-condensing
Weight: T and C models: 49.9 kg (110 lbs), S model: 46.7 kg (103 lbs), Forepump: 25.9 kg (57 lbs)
Dimensions (HxWxD): Standalone MS: 50 x 32 x 77 cm (20 x 13 x 30 inches), Clarus SQ 8 T GC/MS (with Autosampler): 83 x 98 x 82 cm (33 x 39 x 32 inches)