Audit Diagnostics - SAPPHIRE 200®

Manufactured by  Audit Diagnostics
Follow this Equipment

Sapphire 200® is a direct reading random access fully automated bench top chemistry analyser, providing quality results...

Sapphire 200® is a direct reading random access fully automated bench top chemistry analyser, providing quality results cost effectively at a rate of 200 tests per hour.
Active Questions & AnswersAsk a Question

There are no current Discussions

Need Equipment Support?

Request Support
Features of SAPPHIRE 200®
  • Patent pipetting system, accurate and long life   
  • Accuracy to 0.1Μl sampling, optimum laboratory quality   
  • Sample volume low to 2Μl   
  • Reaction volume low to 180Μl - save cost for small labs, consumable compare to big systems   
  • Reagent cooling with optional On/Off key to keep reagent at best situation, without frequently storing in fridge   
  • Reagent level detection and calculate residual test number   
  • Every test under control   
  • Reusable cuvettes, changeable by set   
  • Reaction cuvettes 7 steps auto-wash   
  • Save cost and prevent problem of carry over   
  • Reaction curve review   
  • Windows based software, functional run monitor and QC management   
  • User friendly interface   
  • Password protect authorized user   
  • Easy maintenance modular system
General Specifications
Depth 420 mm
Height280 mm
Width 680 mm
Power Requirements 220 ± 5 V AC (or 110 ± 3 V AC, optional), 250 VA, 50/60 Hz
Peak Power250 VA
Weight70 kg (main unit with CPU)
Additional Specifications

System General   
System Type: Open, Automated, Discrete, Random access,   
Patient Prioritized, Clinical Chemistry Analyzer   
Throughput: 300 Tests / Hour   
Assay Item: Maximum 45   
Water Consumption: 10 Lt / Hour   
Analytical Method: End Point, Kinetic, Fixed Time, Linearity and Nonlinearity   
Analysis Programmable   
Parameters :No limit   
   
Sample Handling   
Sample Tray: 60 positions/disk, non-fixed sample positions   
including calibrator and control positions   
Sample Volume: 2 - 50Μl (adjustable in 0.1 Μl step)   
Content of Test: Clinical Chemistry, ITA, TDM, DOA   
Sample Container: Primary tubes of 5, 7 & sample cups   
Sample Probe: Temperature controlled level detection, high   
pressure washing   
Stat Sampling: Immediate access at any positions   
   
Reagent Handling   
Reagent Tray: 45 positions with Peltier cooling   
Reagent Volume:    
R1: 25 - 350Μl   
R2: 0 or 10 - 150Μl (adjustable in 1 Μl step)   
Reagent Bottles: 50ml, 20ml   
Reagent Cooling: Ambient minus 12°C, with independent On/Off key   
Residual Vol.: Level detection   
Reagent Probe: Temperature controlled level detection, high   
pressure washing   
   
Reaction   
Reaction Tray: 120 reusable (5Sets) PMMA cuvettes   
Reaction Volume: 180 - 500 Μl   
Photometry Optics:    
Mono/bi-chromatic measurement   
8 Wavelengths: 340, 405, 450, 510, 546, 578,   
600, 700nm   
Absorbance Range: 0 - 3.0   
Light Source: Halogen lamp (12V/35W)   
Optical Path: 6mm   
Washing Unit: 7 Stages automatic laundry unit   
   
User Interface   
Display Resolution: 1024 x 768   
Software: Windows 2000 or higher   
Auxiliary Data: Non limit   
Interface: RS-232 C port for Bi-directional Communication   
Run Monitor: Operation status on screen   
Printer: External   
Calibration: Linear (Two Point and Multi Point), Factor, and   
Non-linear Multi Point   
Control: Levy-Jennings, Monthly Statics   
Environmental: 15 - 30 10 - 90% rel. Hum.

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com