Sakura - Tissue Tek VIP 2000

Manufactured by  Sakura
Follow this Equipment

The user friendly V.I.P. processors are not only designed for maximum reliability, but they also ensure the ultimate safety of your specimens.

Computer Power  
The V.I.P. control panel permits you to prepare and store up to 10 different processing programs. A simple touch of the key pad instructs the sophisticated micro-processor which program to use.  
 
Power of Peace of Mind  
The user friendly V.I.P. processors are not only designed for maximum reliability, but they also ensure the ultimate safety of your specimens. The computer monitors the entire process to continuously maintain all parameters under virtually any circumstances. Even in the event of power failure, the system will protect the integrity of your specimens.  
 
Bench-Top or Floor Model  
The bench-top V.I.P. processors are compact units that fit neatly on a lab bench. Where space is at a premium, free-standing vertical instruments will prove convenient - using only 3.3 square feet of floor space.  
 
4-Way Power  
Tissue-Tek V.I.P processors combine four key elements to produce a better block: alternating pressure, vacuum, heat, and agitation. These elements are programmable in each of 10 reagent and 4 paraffin stations.  
 
Microprocessor-Controlled Electronics  
V.I.P. processors are controlled by a sophisticated, user-friendly computer. The powerful microprocessor at the heart of the computer methodically executes every programmed function. The cleaning cycle, the P/V cycle and diagnostic systems are pre-programmed.  
 
The 14 stage processing cycle is user programmable. You may create and store up to 10 processing programs detailing time, heat, and P/V cycle at each station.
Active Questions & AnswersAsk a Question

There are no current Discussions

Tissue Processors Service ProvidersView All (1)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features

There are no Features available.

General Specifications
Weight242 lbs
Additional Specifications

Dimensions/Floor Model1.09m (43") high, 0.61m (24") deep, 0.51m (20") wide  
Dimensions/Bench Model0.58m (23") high, 0.61m (24") deep, 1.02m (40") wide  
Voltage100-115 VAC, 50-60 Hz or 220-240 VAC, 50Hz  
Retort Capacity100 specimens  
Reagent ReservoirsTen 3-liter reagent reservoirs, 2 cleaning reagent reservoirs and 2 fume filters  
Oven CapacityFour 3-liter interchangeable paraffin reservoirs  
Operator ProgrammingTen retained processing programs and a self-calculating delay timer - up to 99 days, 11 hours, 59 minutes  
P/V Cycle Time30 seconds ambient, 90 seconds pressure, 30 seconds ambient, 90 seconds vacuum  
OutputsExternal warning relay

Looking for

Sakura - Tissue Tek VIP 2000?

Shop on LabX.com