Audit Diagnostics - SAPPHIRE 600 PLUS
Sapphire 600® Plus fully automated 600 tests per hour compact Clinical Analyser. Providing up 600 tests per hour...
Active Questions & AnswersAsk a Question
There are no current Discussions
Need Equipment Support?
Documents & Manuals
There are no Documents or Manuals available.
Features of SAPPHIRE 600 PLUS
- 600 tests/hour, including ISE
- Auto-rerun with Auto-dilution
- Sample Pre-dilution
- 24 Hour Reagent Colling at 10°C Below Ambient
- Individual Probes for Sample, R1 and R2
- On-board Cuvette Washing
- Long Life Individual Cuvettes
- Barcoded Reagent and Samples
- Primary Tubes 5,7,10 ml
- 80 Position Sample Tray
- 50 Position Reagent Carousel
- 60 Position Cuvette Rotor
- 2 Position Stirrer
- Vertical Obstruction Detection
- Weight Based Level Sensing for Water Cleaning Solution and Waste
- Separation of Bio-Hazardous Waste
- Result Re-calculation Facility
- Storage of Reagent Blank OD and Calibration OD
General Specifications
Depth | 580 mm |
Height | 450 mm |
Width | 800 mm |
Power Requirements | AC110-220V 50/60Hz (Auto Detecting) |
Weight | 45 kg |
Additional Specifications
Measurement
System: Discrete, single line random access, multi-test analysis
Number of tests on board: 50 items max.
Throughput: Up to 360 tests / hour and 600 tests per hour with ISE
Analytical method: End point, Kinetic Initial rate ISE
Calibration curve: Linear, Non-Linear, Multi-Point
Sample Handling
Contents of test: Clinical chemistry, Homogeneous, immuno-assay, TDM, DOA
Sample container: Primary Tubes 5,7,10ml + Sample Cups
Sample number: 80 samples / tray
Sample volume: 3-50µ| (0.1µ| steps)
Automatic dilution: Dilution ration: 10 - 100
Stat sample measurement: Immediate Access and Execution
Sample Identification: Position ID, Bar-code ID (option)
Reagent Handling
Reagent tray: 50 positions cooled
Reagent bottle: 20ml 50ml
Reagent volume: 5-300µ| (1µ| step)
Reagent cooling temperature: Ambient -10°C
Residual volume information: Level Detection System
Reagent identification:Barcode Positive ID
Tray exchange: Continuous
Reaction
Curvette material: Glass
Reaction liquid volume: 250µ| min.
Reaction temperature: 37°C ± 0.1°C
Wavelength (nm):
Mono + Bio-Chromatic with multi-wavelength
Diffraction Grating - 12 Wavelengths
340 / 376 / 415 / 450 / 505 / 546 / 570 / 600 / 660 / 700 / 750
Light Source: Tungsten halogen lamp
Linear Range: OD 0-2.5
Cuvette Washing: By the automatic washing system
Water Consumption:Max 5 litres / hour
User Interface
Run Monitor: Operation status on screen
Quality Control: Levy-Jennings
Data Storage Capacity:
Unlimited number of methods
Data files for samples, controls and calibrators
Printer: External
Environmental: 18~28°C 10-90% relative humidity
Data: Calibration curves for unlimited number of calibrators
Stats input