Audit Diagnostics - SAPPHIRE 600 PLUS

Manufactured by  Audit Diagnostics
Follow this Equipment

Sapphire 600® Plus fully automated 600 tests per hour compact Clinical Analyser. Providing up 600 tests per hour...

Sapphire 600® Plus fully automated 600 tests per hour compact Clinical Analyser. Providing up 600 tests per hour including ISE with on board laundry bar-coded reagents and samples.
Active Questions & AnswersAsk a Question

There are no current Discussions

Need Equipment Support?

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of SAPPHIRE 600 PLUS
  • 600 tests/hour, including ISE 
  • Auto-rerun with Auto-dilution 
  • Sample Pre-dilution 
  • 24 Hour Reagent Colling at 10°C Below Ambient 
  • Individual Probes for Sample, R1 and R2 
  • On-board Cuvette Washing 
  • Long Life Individual Cuvettes 
  • Barcoded Reagent and Samples 
  • Primary Tubes 5,7,10 ml 
  • 80 Position Sample Tray 
  • 50 Position Reagent Carousel 
  • 60 Position Cuvette Rotor 
  • 2 Position Stirrer 
  • Vertical Obstruction Detection 
  • Weight Based Level Sensing for Water Cleaning Solution and Waste 
  • Separation of Bio-Hazardous Waste 
  • Result Re-calculation Facility 
  • Storage of Reagent Blank OD and Calibration OD
General Specifications
Depth 580 mm
Height450 mm
Width 800 mm
Power Requirements AC110-220V 50/60Hz (Auto Detecting)
Weight45 kg
Additional Specifications

Measurement 
System: Discrete, single line random access, multi-test analysis 
Number of tests on board: 50 items max. 
Throughput: Up to 360 tests / hour and 600 tests per hour with ISE 
Analytical method: End point, Kinetic Initial rate ISE 
Calibration curve: Linear, Non-Linear, Multi-Point 
 
Sample Handling 
Contents of test: Clinical chemistry, Homogeneous, immuno-assay, TDM, DOA 
Sample container: Primary Tubes 5,7,10ml + Sample Cups 
Sample number: 80 samples / tray 
Sample volume: 3-50µ| (0.1µ| steps) 
Automatic dilution: Dilution ration: 10 - 100 
Stat sample measurement: Immediate Access and Execution 
Sample Identification: Position ID, Bar-code ID (option) 
 
Reagent Handling 
Reagent tray: 50 positions cooled 
Reagent bottle: 20ml 50ml 
Reagent volume: 5-300µ| (1µ| step) 
Reagent cooling temperature: Ambient -10°C 
Residual volume information: Level Detection System 
Reagent identification:Barcode Positive ID 
Tray exchange: Continuous 
 
Reaction 
Curvette material: Glass 
Reaction liquid volume: 250µ| min. 
Reaction temperature: 37°C ± 0.1°C 
Wavelength (nm):  
Mono + Bio-Chromatic with multi-wavelength 
Diffraction Grating - 12 Wavelengths 
340 / 376 / 415 / 450 / 505 / 546 / 570 / 600 / 660 / 700 / 750 
Light Source: Tungsten halogen lamp 
Linear Range: OD 0-2.5 
Cuvette Washing: By the automatic washing system 
Water Consumption:Max 5 litres / hour 
 
User Interface 
Run Monitor: Operation status on screen 
Quality Control: Levy-Jennings 
Data Storage Capacity:  
Unlimited number of methods 
Data files for samples, controls and calibrators 
Printer: External 
Environmental: 18~28°C 10-90% relative humidity 
Data: Calibration curves for unlimited number of calibrators 
Stats input

Looking for New or Used Equipment?

Shop on LabX

Shop on Labx.com