Agilent Technologies - 1260 Infinity Analytical SFC

Manufactured by  Agilent Technologies
Follow this Equipment

Easy-to-use SFC system for chiral and a-chiral separations

The 1260 Infinity Analytical SFC system provides a tenfold increase in sensitivity compared to existing SFC solutions. The system comprises a modified 1260 Infinity Binary LC coupled to an Aurora SFC Fusion A5 module for conversion of gaseous CO2 to the supercritical state.     
   
Super critical fluid chromatography (SFC) is a seamless extension of conventional HPLC, for superior resolution of chiral as well as a-chiral compounds. Advantages over conventional HPLC incude unique selectivity, reduced consumption of organic solvent and ultrafast separation at moderate operating pressures.
Active Questions & AnswersAsk a Question

Recent Questions & Answers

avatar placemark

Asked byDmW

avatar placemark

Asked byDmW

SFC Supercritical Fluid Chromatography Service ProvidersView All (16)

Request Support
Features of 1260 Infinity Analytical SFC
  • Available as complete system or as upgrade to existing Agilent 1100, 1200 and 1260 LC systems     
  • Only SFC system with 600 bar capability     
  • Dynamic range greater than 10,000 for enantiometric excess and quantitation of impurities     
  • Different solvent selection choices for a wide range of organic modifiers to exploit unique selectivity     
  • Combined Aurora and Agilent solvent delivery system for delivery of CO2 flow for highest sensitivity     
  • Ten- to fifteen fold lower operating costs by using standard grade gaseous CO2 instead of highly expensive SFC grade dip tube CO2     
  • Optional column screening kit or full method development features available for fast, straightforward column and modifier selection     
  • MS compatibility with the Agilent 6100 Series Single Quadrupole LC/MS systems     
  • Low solvent consumption and less waste generation for true green chemistry     
  • Agilent instrument and service quality and IQ/OQ services available     
  • Full control through Agilent ChemStation
General Specifications

There are no General Specifications available.

Additional Specifications

Pumping System     
Flow range:      
up to 5 mL/min     
Composition range:     
0-100%     
SFC primary fluid:      
CO2     
Metering pump noise:      
< 1%     
     
Back Pressure Regulation     
Back pressure regulator range:     
100-400 bar     
Back pressure regulator noise:      
< ± 0.5 bar     
     
DAD     
Short-term noise (ASTM):      
< ±0.025 mAU at 254 nm typical     
Wavelength range:     
190 – 950 nm