FRITSCH GmbH - 12 DynaSizer
The typical areas of application>:
Smallest sample volumes: For measurements with the Nano Part...
The typical areas of application:
Smallest sample volumes: For measurements with the Nano Particle Sizer ANALYSETTE 12 DynaSizer only smallest sample volumes of < 50 µl are necessary, which are applied directly onto the optical measuring cell inside the instrument; making disposables such as cuvettes or similar obsolete. Due to the intelligent design, cleaning is as easy as a child’s play.
Measurement of ultra-thin layers: With the Nano Particle Sizer ANALYSETTE 12 DynaSizer the strength of the measurement layer can be variably adjusted. This enables measurements of even extremely thin layers of suspension and prevents unwanted multi-scattering effects. It also facilitates the measurement of highly concentrated suspensions as well as in opaque media.
Variable laser power: The power of the laser of the Nano Particle Sizer ANALYSETTE 12 DynaSizer is variably adjustable and allows measurements of very dark samples or highly concentrated suspensions of up to 40 wt.%.
The technology:
The new Nano Particle Sizer ANALYSETTE 12 DynaSizer uses the Dynamic Light Scattering as a measuring method and therefore enables the measurement of particle size distributions between1 nm – 6 Μm. With the Nano Particle Sizer ANALYSETTE 12 DynaSizer smallest sample quantities and in an extreme wide concentration-range of 0.0003 % up to 40 % are no problem.
Active Questions & AnswersAsk a Question
There are no current Discussions
Particle Size Analyzers Service ProvidersView All (2)
Documents & ManualsView All Documents
Features of 12 DynaSizer
- Particle size measurement via dynamic light scattering at a constant scattering angle of 135°
- Measuring range of 1 nm – 6 Μm
- Extremely easy handling
- Smallest sample quantities < 50 Μl
- Simple sample feeding directly into the instrument
- Ultra-Thin Layer – an extremely thin measurement layer avoids multiple scatterings
- Particle concentrations from 0.0003 % up to 40 %
- Dark dispersions like ink or oil are measureable without any difficulties
- Limitation of laser-induced-temperature-effects
- Sample temperature selectable between 15ºC and 70ºC
- Variable laser intensity according to the dispersion concentration
- ISO 13321 / 21 CFR part 11
- Unique algorithm for particle size calculation
General Specifications
Depth | 28 cm |
Height | 30 cm |
Width | 33 cm |
Power Requirements | 110 / 220 V |
Weight | 12 kg |
Additional Specifications
Analysis method: Dynamic Light Scattering
Dispersion: Wet
Measurement range: 1 nm – 6 Μm
Liquid quantity in the sample circuit: min. 50 µl - max. 5 ml
Typical measurement time: 30 sec to 5 min. depending on sample and measurement settings
Reproducibility: > 5%
Laser diode characteristics: 658 nm/ 75 mW